Joint image and motion reconstruction for PET using a B-spline motion model.
2012
We present a novel joint image and motion reconstruction method for PET. The method is based on gated data and reconstructs an image together with a motion function. The motion function can be used to transform the reconstructed image to any of the input gates. All available events (from all gates) are used in the reconstruction. The presented method uses a B-spline motion model, together with a novel motion regularization procedure that does not need a regularization parameter (which is usually extremely difficult to adjust). Several image and motion grid levels are used in order to reduce the reconstruction time. In a simulation study, the presented method is compared to a recently propos…
Monte Carlo dosimetric study of the BEBIG Co-60 HDR source
2005
Although not as widespread as Ir-192, Co-60 is also available on afterloading equipment devoted to high dose rate brachytherapy, mainly addressed to the treatment of gynaecological lesions. The purpose of this study is to obtain the dosimetric parameters of the Co-60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there are no dosimetric data available in the literature. The Monte Carlo code GEANT4 has been used to obtain the TG43 parameters and the 2D dose rate table in Cartesian coordinates of the BEBIG Co-60 HDR source. The dose rate constant, radial dose function and anisotropy function have been calculated and are presented in a tabular form as w…
End-to-end tests using alanine dosimetry in scanned proton beams
2018
This paper describes end-to-end test procedures as the last fundamental step of medical commissioning before starting clinical operation of the MedAustron synchrotron-based pencil beam scanning (PBS) therapy facility with protons. One in-house homogeneous phantom and two anthropomorphic heterogeneous (head and pelvis) phantoms were used for end-to-end tests at MedAustron. The phantoms were equipped with alanine detectors, radiochromic films and ionization chambers. The correction for the 'quenching' effect of alanine pellets was implemented in the Monte Carlo platform of the evaluation version of RayStation TPS. During the end-to-end tests, the phantoms were transferred through the workflow…
Image-based MRI Gradient Estimation
2017
In order to reduce geometric distortion phenomena in MR images, every MRI system main magnet undergoes a shimming process. Since this process aims at optimizing magnetic field homogeneity within a so-called uniformity sphere, image quality outside this sphere is neglected. Since the fields vary smoothly in space, MR signal-to-noise ratio is still non-zero just outside the uniformity region, but correction of MR image distortion fails due to lack of magnetic field knowledge outside it. We propose a novel algorithm for measuring all the fields involved in the generation of images. Our proposal is based on exploitation of the distortion which can be observed in images of a known phantom. The p…
Comparison of the strain field of abdominal aortic aneurysm measured by magnetic resonance imaging and stereovision: a feasibility study for predicti…
2015
International audience; The prediction of the risk of rupture of abdominal aortic aneurysm (AAA) is a complex problem. Currently the criteria to predict rupture of abdominal aortic aneurysms are aneurysm diameter and growth rates. It is generally believed that study of the wall strain distribution could be helpful to find a better decision criterion for surgery of aortic aneurysms before their rupture. The wall strain distribution depends on many biological and biomechanical factors such as elastic properties of the aorta, turbulent blood flow, anatomy of the aorta, presence of thrombus or not and so on. Recently, numerical simulations to estimate rupture-potential have received many attent…
Characterization of the complete fiber network topology of planar fibrous tissues and scaffolds
2010
Understanding how engineered tissue scaffold architecture affects cell morphology, metabolism, phenotypic expression, as well as predicting material mechanical behavior has recently received increased attention. In the present study, an image-based analysis approach that provides an automated tool to characterize engineered tissue fiber network topology is presented. Micro-architectural features that fully defined fiber network topology were detected and quantified, which include fiber orientation, connectivity, intersection spatial density, and diameter. Algorithm performance was tested using scanning electron microscopy (SEM) images of electrospun poly(ester urethane)urea (ES-PEUU) scaffo…
In vitro perception of low-contrast features in digital, film, and digitized dental radiographs: A receiver operating characteristic analysis
2005
Objective To compare experimentally the image quality of charged-coupled device (CCD)-based digital, flatbed scanner digitized, and dental film radiographs. Study design High-contrast standardized radiographs of an aluminum step wedge containing boreholes were obtained on dental radiographic film (F) and a CCD receptor (D). Digitization (S) was done with a flatbed scanner. Each radiograph was separated into 23 single images, 18 of which showed a dark spot. Thirty observers indicated their confidence on the visibility of the spots for a receiver operating characteristic (ROC) analysis. Results Mean Az values (area beneath the ROC curves) differed significantly (P < .05), being highest for D …
Characterisation of two new radiochromic gel dosimeters TruView™ and ClearView™ in combination with the vista™ optical CT scanner: A feasibility study
2018
This study aims at characterising the properties of TruView™ and ClearView™ two new gel dosimeters (Modus Medical Devices Inc.) and at studying the feasibility of relative dosimetry using these dosimeters and the Vista™ Optical CT scanner to accurately evaluate dose.In this work, we investigated key dosimetric aspects (dose response, energy and dose rate dependence) and stability of these radiochromic gels initiated in preliminary works (Huet et al., 2017; Colnot et al., 2017) using spectrophotometric measurements. Moreover, by mean of optical CT scanning (Vista™), their performances to measure relative depth dose (PDD) and cross profiles were analysed.TruView™ and ClearView™ present a line…
Metabolic impact of Partial Volume Correction of [18F]FDG PET-CT oncological studies on the assessment of tumor response to treatment
2014
AIM: The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. METHODS: Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-I) and after (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated f…
An enhanced random walk algorithm for delineation of head and neck cancers in PET studies
2017
An algorithm for delineating complex head and neck cancers in positron emission tomography (PET) images is presented in this article. An enhanced random walk (RW) algorithm with automatic seed detection is proposed and used to make the segmentation process feasible in the event of inhomogeneous lesions with bifurcations. In addition, an adaptive probability threshold and a k-means based clustering technique have been integrated in the proposed enhanced RW algorithm. The new threshold is capable of following the intensity changes between adjacent slices along the whole cancer volume, leading to an operator-independent algorithm. Validation experiments were first conducted on phantom studies:…