Search results for "PhotoPlethysmoGraphy"

showing 10 items of 53 documents

Optisko metožu un ierīču izstrāde kardiovaskulārā stāvokļa kontrolei reālā laikā

2013

Elektroniskā versija nesatur pielikumus

capillary refillwireless transmissionFotopletizmogrāfijamultispectral photoplethysmographyFizikaMedical physicsRekapilarizācijaCardiovascular system - Diseases - DiagnosisKardiovaskulārā sistēma - Slimības - DiagnostikaPhotoplethysmographyMedicīniskā fizikaMultispektrālā fotopletizmogrāfijaBezvadu pārraide
researchProduct

Clinical evaluation of automated capillary refill time estimation in dogs and cats

2019

In this study, we clinically evaluated a pulse oximeter-based device for automated capillary refill time (CRT) estimation in dogs and cats. CRT can reveal conditions like shock or anemia in dogs and cats. However, visual CRT estimation has low repeatability, and the available optical systems for automated estimation are not suitable for pets. We evaluated a custom-made portable CRT measuring device on various measurement sites of 12 dogs and 11 cats with parallel visual CRT estimation on the gum by treating veterinarian. The capillary refill was also recorded by a video camera for reference. The visual and video procedures were moderately correlated with the coefficient of 0.61; visual CRT …

dogsgenetic structurespulse oximetermicrocirculationVideo cameraCapillary refill time01 natural scienceslaw.invention010309 optics03 medical and health sciences0302 clinical medicinelawTime estimationPhotoplethysmogram0103 physical sciencesMedicineCATSmedicine.diagnostic_testPulse (signal processing)business.industrycatsRepeatabilityCapillary refill3. Good health:NATURAL SCIENCES::Physics::Atomic and molecular physics [Research Subject Categories]capillary refill testphotoplethysmographybusinessClinical evaluation030217 neurology & neurosurgeryBiomedical engineering
researchProduct

A portable multisensor system to assess cardiorespiratory interactions through photoplethysmography

2022

Nowadays, the ever-growing interest to health and quality of life of individuals and the advancements in electronic devices technology are pushing the development of portable and wearable biomedical devices able to pursue a minimally invasive monitoring of physiological parameters in daily-life conditions. Such devices can now carry out a real-time assessment of the subjects’ overall health status and possibly even detect ongoing diseases. In this context, we have designed and implemented a multisensor portable system able to perform synchronous real-time acquisitions of electrocardiographic (ECG), photoplethysmographic (PPG) and airflow breathing signals. We investigated cardiorespiratory …

electrocardiography (ECG)photoplethysmography (PPG)Granger causality.breathing signalPortable biomedical deviceSettore ING-INF/06 - Bioingegneria Elettronica E Informaticacardiorespiratory interactionSettore ING-INF/01 - Elettronica2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)
researchProduct

Low-invasive multisensor real-time acquisition system for the assessment of cardiorespiratory and skin conductance parameters

2022

In recent years, the attention to the health and comfort of the individual, together with the electronic miniaturization progress, have led to an increased interest in the development of biomedical devices that are able to acquire a multitude of biomedical signals. Such devices should be wearable and comfortable during daily use, to be thus suitable for continuously monitoring psychophysical health states. In this context, we have designed and realized a portable biomedical device capable of real-time acquisition of electrocardiographic (ECG), photoplethysmographic (PPG), breathing and galvanic skin response (GSR) signals, for a noninvasive monitoring of multiple physiological parameters. T…

electrocardiography (ECG)photoplethysmography (PPG)Portable biomedical deviceSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaInternet of Medical Things (IoMT)Settore ING-INF/01 - Elettronicagalvanic skin response (GSR)2022 IEEE 21st Mediterranean Electrotechnical Conference (MELECON)
researchProduct

Measurements of cardiac Pre-Ejection period using a combo PPG-ECG system

2015

The extraction of biomedical parameters, for early disease detection, is assuming today an ever increasing and fundamental importance. In particular, in the cardiologic field, the preejection period (PEP) is the duration of the iso-volumetric left ventricle contraction until the aortic valve opening. This parameter is a non-constant additive delay, which rapidly changes in response to stress, emotion and physical effort. To estimate this period, several wearable electronics devices have been developed in literature, and among them the Impedance Cardiogram equipment is the most used. However, these systems are often expensive and bulky. In this paper, we propose a cost-effective and easy to …

embedded systemECGPhotoplethysmography (PPG)Arterial parameterPulse Wave Velocity (PWV)Settore ING-INF/01 - Elettronica
researchProduct

Blood Pressure Monitoring with a PPG Embedded System

2014

embedded systemPhotoPlethysmoGraphysensorSettore ING-INF/02 - Campi ElettromagneticiSettore ING-INF/01 - ElettronicaSilicon PhotoMultiplier
researchProduct

Semi-blind Source Extraction Methods: Application to the measurement of non-contact physiological signs

2018

Non-contact physiological measurements are highlydesirable in many biomedical fields such asdiagnosis of infants, geriartic patients, patients withextreme physical trauma, and fitness and well-being.Remote photoplethysmography is increasingly beingused for non-contact measurement of heart rate fromvideos which is one of the most common biomedicalproperty required for most medical diagnosis. Oneof the common techniques for performing remotephotoplethysmography involves using Blind SourceSeparation (BSS) methods to extract the cardiacsignal from video data.In this context, the objective of this thesis is todevelop different methods in the field of extractionand separation of sources by improv…

integration of biophysical constraints[INFO.INFO-CV] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]L’analyse de composantes indépendantes contraint[INFO.INFO-TS]Computer Science [cs]/Signal and Image Processing[INFO.INFO-TS] Computer Science [cs]/Signal and Image ProcessingRemote photoplethysmographyL’analyse de composantes indépendantes[INFO.INFO-CV]Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Méthodes d’extraction semi-aveugleSemi-blind source extraction methodsIntègration des contraintes biophysiquesConstrained Independent Component AnalysisPhotopléthysmographie à distance
researchProduct

Estimating Heart Rate, Energy Expenditure, and Physical Performance With a Wrist Photoplethysmographic Device During Running

2017

BackgroundWearable sensors enable long-term monitoring of health and wellbeing indicators. An objective evaluation of sensors’ accuracy is important, especially for their use in health care. ObjectiveThe aim of this study was to use a wrist-worn optical heart rate (OHR) device to estimate heart rate (HR), energy expenditure (EE), and maximal oxygen intake capacity (VO2Max) during running and to evaluate the accuracy of the estimated parameters (HR, EE, and VO2Max) against golden reference methods. MethodsA total of 24 healthy volunteers, of whom 11 were female, with a mean age of 36.2 years (SD 8.2 years) participated in a submaximal self-paced outdoor running test and maximal voluntary exe…

medicine.medical_specialty020205 medical informaticsheart rate determinationexercise testHealth InformaticsInformation technology02 engineering and technology03 medical and health sciences0302 clinical medicinePhotoplethysmogramenergy metabolismStatisticsHeart rateheart rate0202 electrical engineering electronic engineering information engineeringmedicineOriginal Paperbusiness.industry030229 sport sciences217 Medical engineeringfitness trackersT58.5-58.64oxygen consumptionIntensity (physics)Mean absolute percentage errorEnergy expenditurePhysical performanceHeart Rate DeterminationPhysical therapyphotoplethysmographyObjective evaluationPublic aspects of medicineRA1-1270business
researchProduct

A silicon photomultiplier-based analog front-end for DC component rejection and pulse wave recording in photoplethysmographic applications

2022

The growing attention towards healthcare and the constant technological innovations in the field of semiconductor components have allowed a widespread availability of smaller devices, suitable to be worn and able to continuously acquire physiological signals. Wearable devices are, however, more prone to yield signals corrupted by artifacts caused by movement. This issue is particularly relevant in photoplethysmographic (PPG) applications where also, to exploit the whole dynamic range of the acquisition device, the DC component of the signal should be removed and the AC component amplified. In this context, we have designed and realized an analog front-end (AFE) suitable to be integrated wit…

photoplethysmography (PPG)bio-sensing applicationSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaAnalog front-end (AFE)wearable health devices (WHD)silicon photomultiplier (SiPM)Settore ING-INF/01 - Elettronica2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)
researchProduct

Gingivīta novērtēšana, izmantojot attālinātu fotopletismogrāfiju

2020

Pētījuma mērķis ir novērtēt smaganu perfūziju izmeklējamām personām izmantojot photopletizmogrāfijas metodi. Viens no pētījuma mērķiem bija reģistrēt kapsacīna izraisīto neiro-iekaisuma efektu. Metodoloģija Šķērsgriezuma pētījums, tika veikts iekļaujot nelielu izmeklējamo personu grupu , izmeklējamās personas pirms pētījuma veikšanas tika iepazīstinātas ar protokolu un rakstiski apstiprināja dalību pētījumā. Pētījuma gaitā smaganu perfūzijas tika reģistrēta miera apstākļos, un aplicējot uz smaganu virsmas kapsacīnu saturošu piparu ekstraktu, kas izraisīja pārejošu neirogēnu iekaisumu, ar tam raksturīgo hiperēmiju. Signāla reģistrācija tika veikta novietojot uz galvas izmeklējamai personai f…

remote photoplethysmographyinflammatory effectGingivitiscapsaicinblood perfusionMedicīna