Search results for "Photodegradation"

showing 10 items of 153 documents

Preparation and photoactivity of nanocrystalline TiO2 powders obtained by thermohydrolysis of TiOSO4

2013

Nanocrystalline TiO2 photocatalysts were synthesized in mild conditions by thermohydrolysis of TiOSO4 in water at 100 °C and post-calcination treatment at various temperatures. The TiO2 powders were characterized by X-ray diffraction, X-ray photoelectron spectroscopy, specific surface area determinations, scanning electron microscopy and electron paramagnetic resonance measurements. The photoactivity of the samples was tested employing the photodegradation of 4-nitrophenol in liquid–solid regimen and the photooxidation of gaseous 2-propanol. The best results were obtained with the powder calcined at 600 °C for 10 h. Surprisingly, the not calcined sample was the most active for the abatement…

ChemistryScanning electron microscopeInorganic chemistryTitanium dioxide TiOSO4Thermohydrolysis Heterogeneous photocatalysisGeneral ChemistryCatalysisNanocrystalline materiallaw.inventionNOHeterogeneous photocatalysischemistry.chemical_compoundX-ray photoelectron spectroscopylawSpecific surface areaTitanium dioxideThermohydrolysisTitanium dioxideCalcinationTitanium dioxide TiOSO4 Thermohydrolysis Heterogeneous photocatalysisSettore CHIM/07 - Fondamenti Chimici Delle TecnologieElectron paramagnetic resonancePhotodegradationTiOSO4Nuclear chemistry
researchProduct

Structural and surface characterization of the polycrystalline system CrxOy · TiO2 employed for photoreduction of dinitrogen and photodegradation of …

1992

The polycrystalline system CrxOy-TiO2, used as a catalyst for photoreactions, was studied by X-ray diffractometric method, visible-ultraviolet diffuse reflectance and infrared spectroscopic methods, surface area determination, and porosimetry to characterize its structural and surface features. Two series of catalysts were prepared by two different methods, namely by coprecipitation and by impregnation. The first series was tested as photocatalysts for the dinitrogen photoreduction in a gas-solid regime and for the phenol photodegradation in a liquid-solid regime. The results indicate that the interaction of chromium ions with OH groups modifies the surface properties of the supports and co…

CoprecipitationChemistryInorganic chemistryPhotocatalysisPorosimetryDiffuse reflectionPhysical and Theoretical ChemistryPhotochemistryPhotodegradationHeterogeneous catalysisChemical reactionCatalysisCatalysisJournal of Catalysis
researchProduct

New flow-multicommutation method for the photo-chemiluminometric determination of the carbamate pesticide asulam

2004

This paper deals with a straightforward automated method for the determination of asulam in water based on the use of a flow manifold including three computer-controlled solenoid valves. The method involves irradiating on an aqueous solution of asulam in glycine buffer at pH 8.3 with UV light during 90 s, then follows the oxidation with potassium permanganate in a sulphuric medium and chemiluminescence-based detection of the resulting photoproducts. The limit of detection thus achieved is 40 mug l(-1). The detector response is linear up to a 5 mg l(-1) asulam concentration and the throughput is 30 samples h(-1). In parallel tests, oxidation with alkaline ferricyanide was also assessed and t…

Detection limitChemiluminescenceChromatographyAqueous solutionSolenoid valvesBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganateAsulamchemistrylawMulticommutationReagentPhotodegradationQUIMICA ANALITICAEnvironmental ChemistryAsulamFerricyanidePhotodegradationSpectroscopyChemiluminescenceAnalytica Chimica Acta
researchProduct

Flow‐Injection Chemiluminescent Determination of Thiamine in Pharmaceutical Samples by On‐line Photodegradation

2004

Abstract A simple, sensitive, and precise method for the determination of thiamine hydrochloride in a flow‐injection system is described. The method is based on the UV irradiation of thiamine in acid medium. Then, the photo‐fragments are oxidized by permanganate in acid medium, and the resultant chemiluminescent intensity is measured. The optimum conditions for the photoreaction and for the chemiluminescence emission were investigated. The method allows the determination of thiamine, over the range 0.05(LOD)–84 mg · l−1, with a throughput of 30 h−1, and a RSD (n, 20) at 20 and 0.5 mg · l−1 of the thiamine level of 2.5 and 1.3%, respectively. The method was applied to pharmaceutical preparat…

Detection limitChromatographyBiochemistry (medical)Clinical BiochemistryThiamine HydrochloridePermanganatefood and beveragesPhotochemistryBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundchemistrylawElectrochemistryPhotochemical degradationThiamineIrradiationPhotodegradationhuman activitiesSpectroscopyChemiluminescenceAnalytical Letters
researchProduct

Photochemical-chemiliminometric determination of aldicarb in a fully automated multicommutation based flow-assembly

2004

[EN] A sensitive and fully automated method for determination of aldicarb in technical formulations (Temik) and mineral waters is proposed. The automation of the flow-assembly is based on the multicommutation approach, which uses a set of solenoid valves acting as independent switchers. The operating cycle for obtaining a typical analytical transient signal can be easily programmed by means of a home-made software running in the Windows environment. The manifold is provided with a photoreactor consisting of a 150 cm long x 0.8 mm i.d. piece of PTFE tubing coiled around a 20 W low-pressure mercury lamp. The determination of aldicarb is performed on the basis of the iron(III) catalytic minera…

Detection limitChromatographyChemiluminescenceAldicarbAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionMercury-vapor lampchemistry.chemical_compoundPotassium permanganatechemistryFully automatedlawMulticommutationTandem-flowPhotodegradationQUIMICA ANALITICAEnvironmental ChemistryPhotodegradationSpectroscopyTransient signalAldicarbChemiluminescence
researchProduct

Analytical strategy photodegradation/chemiluminescence/continuous-flow multicommutation methodology for the determination of the herbicide Propanil

2006

The present paper is dealing with an analytical strategy based on coupling photodegradation, chemiluminescence and multicommutation continuous-flow methodology for the determination of the pesticide Propanil, a common herbicide. The pesticide solution is inserted as small segments sequentially alternated with segments of the solution for adjusting the suitable medium for the photodegradation. Both flow-rates (sample and medium) are adjusted to required time for photodegradation, 2.0 min; and then, the resulting solution is also sequentially inserted as segments alternated with segments of the oxidizing solutions system, 1.00 x 10(-4) mol 1(-1) potassium permanganate in 2.00 mol 1(-1) sulphu…

Detection limitChromatographyChemiluminescenceCorrelation coefficientChemistryAlachlorAnalytical chemistryRepeatabilityAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatePhotoreactionlawMulticommutationPropanilQUIMICA ANALITICAPesticidesPhotodegradationChemiluminescence
researchProduct

A Fully Automated Assembly Using Solenoid Valves for the Photodegradation and Chemiluminometric Determination of the Herbicide Chlorsulfuron

2005

Abstract This paper presents a new photochemiluminescent system for the determination of chlorsulfuron in water samples. The light from a low‐pressure mercury lamp is used as a clean, reproducible, and inexpensive “reagent” for the derivation of the pesticide, performed in glycine buffer at pH 9.5. Then, the photo‐products from irradiation are oxidized by permanganate in sulfuric acid solution. The oxidation reaction was favored by using high temperatures. A comparative study and discussion about the use of polyphosphoric acid instead of sulfuric acid in the oxidation reaction is also presented. The use of solenoid valves allows for the easy, complete automation of the process with low samp…

Detection limitChromatographyChemistryCalibration curveBiochemistry (medical)Clinical BiochemistryPermanganateAnalytical chemistrySulfuric acidBiochemistryRedoxAnalytical Chemistrylaw.inventionMercury-vapor lampchemistry.chemical_compoundlawReagentElectrochemistryPhotodegradationSpectroscopyAnalytical Letters
researchProduct

FI-on line photochemical reaction for direct chemiluminescence determination of photodegradated chloramphenicol.

2002

Abstract A new, simple, clean and selective flow injection strategy based on the tandem photochemical reaction-chemiluminescence detection was applied to the determination of chloramphenicol. The determination is based on the on-line photodegradation of the drug in a glycine buffer at pH 8.8 by using a photoreactor consisting of 697 cm×0.5 mm PTFE tubing helically coiled around an 8 W low-pressure mercury lamp. Photodegradated chloramphenicol is detected by direct chemiluminescence of resulting photo-fragments and their subsequent reaction with potassium permanganate in sulfuric acid medium as oxidant. The method allows the chemiluminescence determination of compounds which do not exhibit n…

Detection limitChromatographyChemistryCalibration curvePhotochemistryDosage formAnalytical Chemistrylaw.inventionPotassium permanganatechemistry.chemical_compoundlawPhotodegradationQuantitative analysis (chemistry)Antibacterial agentChemiluminescenceTalanta
researchProduct

Chemiluminometric photo-induced determination of Strychnine in a Multicommutation flow assembly

2007

This paper deals on the determination of Strychnine, a potent and dangerous pesticide and the analytical procedure is based on the photo-induced chemiluminescence of the pesticide by means of the Multicommutation continuous-flow methodology. Small segments of the pesticide solution were sequentially alternated with segments of the solution for adjusting the suitable medium for the photodegradation. The required time of UV irradiation was obtained by stopped-flow during 150 s; then, the resulting solution formed alternated segments with the oxidizing solution containing 5 × 10−3 mol l−1 Ce(IV) in 0.6 mol l−1 nitric acid. The calibration range, from 2 μg l−1 to 50 mg l−1, resulted in a linear…

Detection limitChromatographyCorrelation coefficientAnalytical chemistryStrychnineAnalytical Chemistrylaw.inventionchemistry.chemical_compoundchemistryNitric acidlawOxidizing agentIrradiationPhotodegradationChemiluminescenceTalanta
researchProduct

Enhanced flow-injection–chemiluminometric determination of sulphonamides by on-line photochemical reaction

2003

Abstract The viability of the tandem photochemical reaction-chemiluminescence detection has been studied for an heterogeneous group of sulphonamides (sulphamethoxazole, sulphadiazine, sulphamerazine, sulphamethoxypyridazine, sulphacetamide, sulphadimidine, sulphanilamide, sulphathiazole and sulphaguanidine) using sulphamethoxazole (whose chemiluminescent behaviour has not been previously reported) as a test substance. The ‘on-line’ photochemical-reaction of sulphonamides provides an enhancing influence on the chemiluminometric response of the drugs during their oxidation by potassium permanganate in sulphuric acid medium (sulphamethoxazole, sulphacetamide, sulphadimidine and sulphanilamide …

Detection limitChromatographyFluorescence spectrometryPhotochemistryBiochemistryOrders of magnitude (mass)Analytical Chemistrylaw.inventionStandard curvePotassium permanganatechemistry.chemical_compoundchemistrylawSulphaguanidineEnvironmental ChemistryPhotodegradationSpectroscopyChemiluminescenceAnalytica Chimica Acta
researchProduct