Search results for "Photoplethysmogram"

showing 4 items of 84 documents

Imaging photoplethysmography for assessment of chronic pain patients

2019

In present pilot study application of multi-spectral imaging photoplethysmography for assessment of chronic pain patients during topical skin heating test was proposed. Photoplethysmography signal was recorded at 420nm, 530nm and 810nm illumination from the skin and corresponding perfusion indexes and perfusion maps were calculated. The novel parameter-PPGflare index was introduced and compared in neuropathic patients and healthy volunteers. Preliminary results suggest that neuropathic patients exhibited significantly lower PPGflare index, and that local heating substantially change PPG waveform at heat exposed skin region. Present study emphasizes advantages of imaging photoplethysmography…

medicine.medical_specialtybusiness.industryPain assessmentPhotoplethysmogramNeuropathic painHealthy volunteersChronic painMedicineRadiologyLaser Doppler velocimetrybusinessmedicine.diseasePerfusionOptical Diagnostics and Sensing XIX: Toward Point-of-Care Diagnostics
researchProduct

<title>Potential of advanced photoplethysmography sensing for noninvasive vascular diagnostics and early screening</title>

2002

Advanced sensor device for shape analysis of the tissue- reflected mean single period photoplethysmography (SPPPG) signals has been designed and clinically tested. The SPPPG signal shape reveals individual features of the patient's cardio-vascular state. Clinical studies of several patient groups (e.g. diabetes mellitus, atherosclerosis obliterans, Raynaud's syndrome) made possible to specify components of the SPPPG signal that are sensitive to the corresponding organic or functional pathologies. Comparison of the right and left arm finger SPPPG signal shapes, for instance, appears to be efficient tool for early screening of unilateral atherosclerosis obliterans.© (2002) COPYRIGHT SPIE--The…

medicine.medical_specialtybusiness.industryPhotoplethysmogrammedicineRadiologybusinessBiomedical engineeringSPIE Proceedings
researchProduct

Usability of photoplethysmography method in estimation of conduit artery stiffness

2011

Three channel photoplethysmography (PPG) signal waveform studies of leg conduit arteries during a provocative occlusion test were performed. PPG waveform second derivative amplitude ratio and arterial pulse wave velocity values showed significant correlations with ultrasound (US) reference method of local and regional arterial stiffness (AS), showing the ability to use PPG for AS change quantitative assessment.

medicine.medical_specialtybusiness.industryUltrasoundmedicine.diseaseSignalmedicine.anatomical_structurePhotoplethysmogramOcclusionArterial stiffnessMedicineWaveformsense organsRadiologybusinessArterySecond derivativeBiomedical engineeringSPIE Proceedings
researchProduct

Physiological parameters measurements in a cardiac cycle via a combo PPG-ECG system

2015

In this paper, we present an innovative way to measure some physiological parameters (such as the pre-ejection period, the pulse transit time, the blood pressure) in a cardiac cycle. A combo PPG-ECG system has been developed and employed to extract both the ECG signal from standard limb leads and simultaneously the photoplethysmography signal from the wrist and the forearm, to calculate the pre-ejection period. This system represents an easy and non-invasive technique to determine these biomedical parameters without using expensive impedance cardiography equipment.

silicon photo-multipliermedicine.diagnostic_testCardiac cycleComputer scienceblood pressurePulse Transit Timemean arterial pressure.SignalSettore ING-INF/01 - ElettronicaImpedance cardiographyBlood pressuremedicine.anatomical_structureForearmpulse transit timePhotoplethysmogrammedicinepre-ejection periodEcg signalBiomedical engineering
researchProduct