Constant gradient magnetic resonance elastography experiments on phantom and bovine liver
2019
International audience; SynopsisMagnetic Resonance Elastography (MRE) is performed by the application of motion-sensitive gradients. In this study, RF pulses are designed with an optimal control algorithm to obtain a desired magnetization phase distribution. Such pulse, in presence of a constant gradient, allows tosimultaneously perform spatially selective excitation and motion encoding. This offers some advantages when compared to standard MRE encoding strategy. Simulations, phantom and ex vivo experiments show that phase-to-noise ratios are improved. These results demonstrate that optimal control-based pulses can be used to encode motion in the MRE excitation phase with relevant advantage…
Optimizing MRI contrast with optimal control theory
2016
International audience; Magnetic Resonance Imaging (MRI) uses the difference in tissue relaxation times to create contrast. Various image weightings can be obtained by tuning acquisition parameters which are usually empirically defined. In this article, optimal control theory is used to design excitation pulses that produce the optimal contrast between given tissues. The designed pulses are tested on numerical phantoms with and without magnetic field inhomogeneities and for the first time in vitro on a small-animal MRI. The reasonable match between simulation and real experiments is promising for the development of such pulses in further in vivo applications.
Enhanced detection of contrast regions in echocardiograms by adaptive quantization
2002
The statistics of ultrasound echo images are governed by Rayleigh statistics. The authors derive some experimentally verifiable predictions of this theory, compare them with experimental results obtained from echocardiographic images, and derive a new color coding scheme, (adaptive quantization) that is adapted to the signal-dependent noise predicted by theory. This results in some technical advantages and in an improved discrimination of regions of the echo image that are enhanced by echo contrast material. >
The anisotropic behaviour of a preoriented poly (ethylene terephthalate) during plastic deformations
1978
Data on the anisotropic tensile behavior of samples cut along several directions of a biaxially oriented PET sheet are here presented. Shear deformations were observed together with the usual elongations. The data are compared with the predictions of a non-linear model recently proposed.
"Figure 15" of "Two-particle azimuthal correlations in photonuclear ultraperipheral Pb+Pb collisions at 5.02 TeV with ATLAS"
2021
The measured $v_2$ and $v_3$ charged-particle anisotropies as a function of charged-particle multiplicity in photonuclear collisions
"Figure 16 and 17" of "Two-particle azimuthal correlations in photonuclear ultraperipheral Pb+Pb collisions at 5.02 TeV with ATLAS"
2021
The measured $v_2$ and $v_3$ charged-particle anisotropies as a function of charged-particle transverse momentum in photonuclear collisions
Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz
2010
To establish Boron Neutron Capture Therapy (BNCT) for non-resectable liver metastases and for in vitro experiments at the TRIGA Mark II reactor at the University of Mainz, Germany, it is necessary to have a reliable dose monitoring system. The in vitro experiments are used to determine the relative biological effectiveness (RBE) of liver and cancer cells in our mixed neutron and gamma fi eld. We work with alanine detectors in combination with Monte Carlo simulations, where we can measure and characterize the dose. To verify our calculations we perform neutron fl ux measurements using gold foil activation and pin-diodes . Material and methods . When L- α -alanine is irradiated with ionizing …
The factorization method for electrical impedance tomography data from a new planar device.
2006
We present numerical results for two reconstruction methods for a new planar electrical impedance tomography device. This prototype allows noninvasive medical imaging techniques if only one side of a patient is accessible for electric measurements. The two reconstruction methods have different properties: one is a linearization-type method that allows quantitative reconstructions; the other one, that is, the factorization method, is a qualitative one, and is designed to detect anomalies within the body.
Study of CT/MRI mutual information based registration applied in brachytherapy
2016
The present work aims to include magnetic resonance imaging (MRI) in a Medical Image-based Graphical platfOrm - Brachytherapy module (AMIGOBrachy) which coupled to the Monte Carlo N-Particle (MCNP6) code allows absorbed dose calculations. Computed tomography (CT) and MRI images were registered using mutual information algorithms to improve tissue segmentation potentially leading to a more accurate treatment planning system.
Design and Validation of an Expanded Disability Status Scale Model in Multiple Sclerosis.
2020
<b><i>Introduction:</i></b> We aimed to develop and validate an Expanded Disability Status Scale (EDSS) model through clinical, optical coherence tomography (OCT), and magnetic resonance imaging (MRI) measures. <b><i>Methods:</i></b> Sixty-four multiple sclerosis (MS) patients underwent peripapillary retinal nerve fiber layer and segmented macular layers evaluation through OCT (Spectralis, Heidelberg Engineering). Brain parenchymal fraction was quantified through Freesurfer, while cervical spinal cord (SC) volume was assessed manually guided by Spinal Cord Toolbox software analysis. EDSS, neuroradiological, and OCT assessment were carried out …