Search results for "Placement."
showing 10 items of 1123 documents
A novel correction method for a low cost sensorless control system of IPMSM electrical drives
2008
In this paper a novel correction method for sensorless Field Oriented Control System of Brushless internal Permanent Magnet Electrical Drives is introduced discussed and experimentally validated. The novelty of this control system is the estimation of rotor speed and angular position is based on the back electromotive force space vector determination, without the aid of voltage probes. Actual voltage signals needed for estimation are replaced with the reference ones given by the current controller. This choice obviously introduces an error that have been vanished by means of a new compensating function or with the aid of data coming from experimental tests. Experimental verifications of the…
Definition of performance requirements and test cases for offshore/subsea winch drive systems with digital hydraulic motors
2019
Abstract A subsea crane is normally mounted on a floating vessel and equipped with a winch system. The crane can operate in water down to 3000 m. The vessel tends to move up and down due to waves. This heave motion makes offshore lifting operations challenging. In order to ease the winch operation in rough sea, the winch can be equipped with additional systems like active heave compensation and constant tension. In active heave compensation and constant tension system, both motion and force control of the winch are important. This paper presents a digital displacement winch drive system and gives a description of challenges related to subsea lifting operations. The operation challenges are …
nalysis, Modeling and Simulation of Mechatronic Systems using the Bond Graph Method
2011
The Bond Graph is the proper choice of physical system used for: (i) Modeling which can be applied to systems combining multidisciplinary energy domains, (ii) Analysis to provide a great value proposition for finding the algebraic loops within the system enabling the process of troubleshooting and eliminating the defects by using the proper component(s) to fix the causality conflict even without being acquainted in the proper system, and (iii) Simulation facilitated through derived state space equations from the Bond Graph model is solved using industrial simulation software, such as 20-Sim. The Bond Graph technique is a graphical language of modeling, in which component energy ports are co…
Diagnosis of papillary muscle rupture after acute myocardial infarction by transthoracic and transesophageal echocardiography.
1993
The sensitivity of transthoracic echocardiography to visualize the structural abnormality of papillary muscle rupture (PMR) after acute myocardial infarction can be anticipated to average about 50%; therefore, we evaluated five patients exhibiting the condition with both transthoracic and transesophageal echocardiography. The use of the two imaging techniques resulted in the fact that no instance of PMR was missed. Using transthoracic echocardiography in two patients and transesophageal echocardiography in four, the ruptured papillary muscle was visualized directly. Mitral insufficiency as an indirect sign was observed in all patients. In one patient the papillary muscle rupture developed i…
The Artificial Kidney Initiation in Kidney Injury 2 (AKIKI2): study protocol for a randomized controlled trial
2019
Abstract Background The Artificial Kidney Initiation in Kidney Injury (AKIKI) trial showed that a delayed renal replacement therapy (RRT) strategy for severe acute kidney injury (AKI) in critically ill patients was safe and associated with major reduction in RRT initiation compared with an early strategy. The five criteria which mandated RRT initiation in the delayed arm were: severe hyperkalemia, severe acidosis, acute pulmonary edema due to fluid overload resulting in severe hypoxemia, serum urea concentration > 40 mmol/l and oliguria/anuria > 72 h. However, duration of anuria/oliguria and level of blood urea are still criteria open to debate. The objective of the study is to compar…
An analytical solution for multilayered beams subjected to ends loads
2014
An alternative model for multilayered beams undergoing axial, shear and bending loads applied at the beam's ends is developed. It is based on a layer-wise kinematics, which inherently fulfills the equilibrium equations at layer level and the interface continuity conditions. This kinematics is suitably expressed by introducing a set of generalized variables representative of the beam midline displacement field, which become the primary variables of the problem governing equations. As a consequence, the proposed beam model exhibits the computational characteristics of an equivalent single layer model and possesses the accuracy of layer-wise beam theories, as well. Closed form solutions for di…
Customized Titanium Lattice Structure in Three-Dimensional Alveolar Defect: An Initial Case Letter
2018
The aim of this initial case report was to provide a new protocol for the clinical application of a patient-specific titanium lattice structure (Yxoss CBR®, ReOSS, Filderstadt, Germany) for customized bone regeneration. To obtain a 3-dimensional reconstruction of a posterior mandible segment in a 61-year-old woman, a patient-specific titanium customized lattice structure was used. As graft material autogenous bone tissue mixed with xenogenic alloplastic material (Bio Oss®, Geistlich Pharma, Wolhusen, Switzerland) was obtained for reconstruction. After a healing period of 6 months, the titanium lattice structure was removed and implant placement (Camlog Screw Line, 3.8/11, Camlog, Wimsheim, …
STRUCTURAL ANALYSIS OF A POSTERIOR STABILITY TOTAL KNEE JOINT REPLACEMENT
2011
Aim of this work is to compare two different total knee prostheses that differ in the shape of the Polyethylene (PE) insert, trying to optimize the shape of the best one, in order to reduce the stress peaks. The study procedure has been divided into the following steps. First step has been the three-dimensional shape acquisition of the two prostheses by means of a COMET5 3D scanner. The morphology of two prototypes of the prostheses has been acquired by elaborating multiple Moirè fringe pattern projected on their surfaces. Second step consisted of the manipulation of these data in a CAD module, that is the interpolation of raw data into parametric surfaces, reducing singularities due to the…
Study of a constrained finite element elbow prosthesis: the influence of the implant placement
2023
Abstract Background The functional results of total elbow arthroplasty (TEA) are controversial and the medium- to long-term revision rates are relatively high. The aim of the present study was to analyze the stresses of TEA in its classic configuration, identify the areas of greatest stress in the prosthesis–bone–cement interface, and evaluate the most wearing working conditions. Materials and methods By means of a reverse engineering process and using a 3D laser scanner, CAD (computer-aided drafting) models of a constrained elbow prosthesis were acquired. These CAD models were developed and their elastic properties, resistance, and stresses were studied through finite element analysis (fin…
Evaluation of diagnostic criteria for analgesic nephropathy in patients with end-stage renal failure: results of the ANNE study
1995
It was found that in Belgium, renal imaging techniques, demonstrating a decreased renal mass of both kidneys combined with either bumpy contours or papillary calcifications, were the only methods to reliably diagnose analgesic nephropathy (AN) in patients with end-stage renal failure. However, these criteria were selected in an area with a high prevalence of this disease (15.6% of the dialysis population at December 1990). To evaluate the criteria selected to diagnose AN in populations with lower or unknown prevalences of AN, the Analgesic Nephropathy Network of Europe (ANNE) was formed, consisting of 23 dialysis units from 14 European countries and Brazil. During 1991-1992, 598 new patient…