Search results for "Plate"
showing 10 items of 1689 documents
Tests of Lobster Eye Optics for Small Space X-ray Telescope
2011
Abstract The Lobster eye design for a grazing incidence X-ray optics provides wide field of view of the order of many degrees, for this reason it can be a convenient approach for the construction of space all-sky X-ray monitors. We present preliminary results of tests of prototype lobster eye X-ray optics in quasi parallel beam full imaging mode conducted using the 35 m long X-ray beam-line of INAF-OAPA in Palermo (Italy). X-ray images at the focal plane have been taken with a microchannel plate (MCP) detector at several energy values from 0.3 to 8 keV. The gain, the field of view and the angular resolution have been measured and compared with theoretical values.
The influence of the quarter wave plates in automated photoelasticity
2002
During the last decades, several methods have been proposed to automate photoelastic analyses. Some procedures are based on the circularly polarised light by using quarter wave plates. However, quarter wave plates are typically matched for a specific wavelength, and an error is introduced at different wavelengths. The error of quarter wave plates affects the measurement of isochromatic and isoclinic data. In this paper, the influence of the errors of quarter wave plates in some of the most common automated photoelastic methods is reviewed. The errors in the photoelastic data are given and the procedures to reduce, or eliminate, them are also suggested.
A Disc-DIRC Cherenkov detector with high resolution micro channel plate photomultiplier tubes
2014
The upcoming PANDA Experiment at FAIR in Germany will be equipped with a novel Cherenkov detector type for high-energy particle identification. This very compact Disc-DIRC detector uses a large disc-shaped fused silica plate of 2 cm thickness as its Cherenkov radiator. The internally reflected Cherenkov light is transported to the rim of the disc where it is focused by quartz light guides onto microchannel plate photomultiplier tubes (MCP-PMTs) with high spatial resolution (pitch 0.5 mm) and high time resolution (σ ≈ 100 ps). The device has an active area of about 3 m2 and will be able to identify pions and kaons with a separation power of more than 3σ in the momentum range up to 4 GeV/c. I…
Excited state systematics in extracting nucleon electromagnetic form factors
2012
We present updated preliminary results for the nucleon electromagnetic form factors for non-perturbatively $\mathcal{O}(a)$ improved Wilson fermions in $N_f=2$ QCD measured on the CLS ensembles. The use of the summed operator insertion method allows us to suppress the influence of excited states in our measurements. A study of the effect that excited state contaminations have on the $Q^2$ dependence of the extracted nucleon form factors may then be made through comparisons of the summation method to standard plateau fits, as well as to excited state fits.
Direct detection of the 229Th nuclear clock transition
2017
Today’s most precise time and frequency measurements are performed with optical atomic clocks. However, it has been proposed that they could potentially be outperformed by a nuclear clock, which employs a nuclear transition instead of an atomic shell transition. There is only one known nuclear state that could serve as a nuclear clock using currently available technology, namely, the isomeric first excited state of 229Th (denoted 229mTh). Here we report the direct detection of this nuclear state, which is further confirmation of the existence of the isomer and lays the foundation for precise studies of its decay parameters. On the basis of this direct detection, the isomeric energy is const…
Energy loss measurement of protons in liquid water
2011
The proton stopping power of liquid water was, for the first time, measured in the energy range 4.7-15.2 MeV. The proton energies were determined by the time-of-flight transmission technique with the microchannel plate detectors, which were especially developed for timing applications. The results are compared to the literature values (from ICRU Report 49 (1993) and Janni's tabulation (1982 At. Data Nucl. Data Tables 27 147-339)) which are based on Bethe's formula and an agreement is found within the experimental uncertainty of 4.6%. Thus, earlier reported discrepancy between the experimental and literature stopping power values at lower energies was not observed at the energies considered …
An extended Ritz formulation for buckling and post-buckling analysis of cracked multilayered plates
2018
Abstract An extended Ritz formulation for the analysis of buckling and post-buckling behaviour of cracked composite multilayered plates is presented. The formulation is based on: (i) the First-order Shear Deformation Theory to model the mechanics of the multilayered plate; (ii) the von Karman’s theory to account for geometric non-linearities ; (iii) the use of an extended set of approximating functions able to model the presence of an embedded or edge crack and to capture the crack opening fields as well as the global behaviour within a single cracked domain. The numerical results of the buckling analyses and the equilibrium paths in the post-buckling regime are compared with the results fr…
Origin of the plateau in the temperature dependence of the normalized magnetization relaxation rate in disordered high-temperature superconductors
2008
The temperature $T$ dependence of the normalized magnetization relaxation rate $S$ in optimally doped ${\text{YBa}}_{2}{\text{Cu}}_{3}{\text{O}}_{7\ensuremath{-}\ensuremath{\delta}}$ films with the external dc magnetic field $H$ oriented along the $c$ axis exhibits the well-known plateau in the intermediate $T$ range, associated with the presence of elastic (collective) vortex creep. The disappearance of the $S(T)$ plateau in the high-$H$ domain $(H\ensuremath{\ge}20\text{ }\text{kOe})$ is not completely understood. We show that in the case of high-temperature superconductors with significant quenched disorder the $S(T)$ plateau is directly related to a crossover in the vortex-creep process…
Secondary electron flight times and tracks in the carbon foil time pick-up detector
2014
Carbon foil time pick-up detectors used in the time-of-flight measurements of MeV energy ions have been studied in connection to time-of-flight-energy spectrometer used for heavy ion elastic recoil detection analysis. In experimental coincident TOF-E data characteristic halos are observed around light element isobars, and the origin of these halos were studied. The experimental data indicated that these halos originate from single electron events occurring before the electron multiplication in the microchannel plate. By means of electron trajectory simulations, this halo effect is explained to originate from single electron, emitted from the carbon foil, hitting the non-active area of the m…
Advanced models for nonlocal magneto-electro-elastic multilayered plates based on Reissner mixed variational theorem
2019
In the present work, nonlocal layer-wise models for the analysis of magneto-electro-elastic multilayered plates are formulated. An Eringen non-local continuum behaviour is assumed for the layers material; in particular, as usual in plate theories, partial in-plane nonlocality is assumed whereas local constitutive behaviour is considered in the thickness direction. The proposed plate theories are obtained via the Reissner Mixed Variational Theorem, assuming the generalized displacements and generalized out-of-plane stresses as primary variables, and expressing them as through-the-thickness expansions of suitably selected functions, considering the expansion order as a free parameter. In the …