Low invasive multisensor acquisition system for real-time monitoring of cardiovascular and respiratory parameters

2020

The recent advances in multiparametric monitoring of biosignals and management of big data prompt for the development of devices and techniques for the extraction of indicators with physiological relevance. In this context, we have designed and realized a portable electronic system, equipped with simple biomedical sensors, able to synchronously record multiple electrocardiographic (ECG), photoplethysmographic (PPG) and breathing signals, for carrying out a non-invasive monitoring of several cardiovascular parameters. In this work, we show the results of preliminary measurements performed following a specific physiological protocol (i.e., deep breathing with 10 s per cycle). The system allow…

Computer scienceWearable electronics portable system electrocardiography (ECG) photoplethysmography (PPG) heart rate variabilitySettore ING-INF/06 - Bioingegneria Elettronica E InformaticaReal-time computingBreathingExhalationBiomedical sensorsDiaphragmatic breathingHeart rate variabilityContext (language use)Stroke volumeSettore ING-INF/01 - ElettronicaElectronic systems2020 IEEE 20th Mediterranean Electrotechnical Conference ( MELECON)
researchProduct

Transthoracic electrical impedance during extracorporeal hemodialysis in acute respiratory failure ("Shocked Lung syndrome").

1980

The alteration (delta Z0) of transthoracic electrical impedance (TEI) during extracorporeal hemodialysis (EHD) was investigated in two Groups of patients with acute renal and acute respiratory failure, that differed with respect to the severity of respiratory insufficiency. Group I had moderate respiratory failure (FiO2 0.31 +/- 0.10, PaO2 84 +/- 14 mmHg), and Group II had severe respiratory failure (FiO2 0.75 +/- 0.17, PaO2 77 +/- 14 mmHg). There was a significant correlation between increase in TEI (delta Z0) and decrease in body weight (delta BW) in each individual patient, but the slope of regression lines was remarkably flattened in Group II. In Group I, delta TEI was 1.9 +/- 0.9 omega…

DeltaAdultMalemedicine.medical_specialtyRespiratory TherapyPostureUltrafiltrationPulmonary EdemaHematocritCritical Care and Intensive Care MedicineCardiography ImpedanceRenal DialysisInternal medicinemedicinePlethysmographHumansAcute respiratory failurePlethysmography ImpedanceRespiratory systemAgedLungmedicine.diagnostic_testbusiness.industryBody WeightAcute Kidney InjuryMiddle AgedExtracorporeal hemodialysismedicine.anatomical_structureRespiratory failureHematocritCardiologyFemalebusinessRespiratory InsufficiencyIntensive care medicine
researchProduct

A portable electronic system for non-invasive real-time acquisition of multiple physiological signals

2019

In this work, we have designed and realised a portable and compact electronic system for the synchronous acquisition of multiple physiological signals. The system employs a Texas Instruments ADS1298 front-end with 24-bit resolution for data acquisition and supports up to 8 channels and 4 kHz sampling rate. The front-end communicates via SPI with a STM32 microcontroller which pre-processes the data and sends them through USB or Bluetooth to a suitable PC application. The system has been realized for the simultaneous acquisition of electrocardiographic (ECG) and photoplethysmographic (PPG) signals, but it can also be employed for acquiring other typologies of signals, e.g. breathing or electr…

Electrocardiographybiomedical signal processingSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaPhotoplethysmographySettore ING-INF/01 - Elettronica
researchProduct

Video-Based Heartbeat Rate Measuring Method Using Ballistocardiography

2017

International audience; Video-based heartbeat rate measurement is a rapidly growing application in remote health monitoring. Video-based heartbeat rate measuring methods operate mainly by estimating photoplethysmography or ballistocardiography signals. These methods operate by estimating the microscopic color change in the face or by estimating the microscopic rigid motion of the head/facial skin. However, the robustness to motion artifacts caused by illumination variance and motion variance of the subject poses main challenge. We present a video-based heartbeat rate measuring framework to overcome these problems by using the principle of ballistocardiography. In this paper, we proposed a b…

EngineeringMean squared errorvideo analyticsComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION02 engineering and technology01 natural sciencesStandard deviationphotoplethysmography and ballistocardiographysymbols.namesakeFacial videoRobustness (computer science)Photoplethysmogram0202 electrical engineering electronic engineering information engineeringmedicineComputer vision[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Electrical and Electronic EngineeringNoncontact[ PHYS.PHYS.PHYS-INS-DET ] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Instrumentationmedicine.diagnostic_testbusiness.industry010401 analytical chemistryPearson product-moment correlation coefficient3. Good health0104 chemical sciencesRemote health monitoringnon-contactFeature (computer vision)BallistocardiographyFace (geometry)symbols020201 artificial intelligence & image processingArtificial intelligencebusinessIEEE Sensors Journal
researchProduct

Effect of Motion Artifact on Digital Camera Based Heart Rate Measurement

2017

International audience; Depression is one of the most prevalent mental disorders, burdening many people world-wide. A system with the potential of serving as a decision support system is proposed, based on novel features extracted from facial expression geometry and speech, by interpreting non-verbal manifestations of depression. The proposed system has been tested both in gender independent and gender based modes, and with different fusion methods. The algorithms were evaluated for several combinations of parameters and classification schemes, on the dataset provided by the Audio/Visual Emotion Challenge of 2013 and 2014. The proposed framework achieved a precision of 94.8% for detecting p…

Engineeringbusiness.product_category[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingRemote patient monitoringMotion artifact effect02 engineering and technology01 natural sciencesMotion (physics)Field (computer science)Photoplethysmography signalComputer vision[ SDV.IB ] Life Sciences [q-bio]/Bioengineering[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/ImagingDigital cameraSkinPatient monitoringDigital cameraremote health monitoringCamerasBiomedical technologyHeart rate measurement[SDV.IB]Life Sciences [q-bio]/BioengineeringArtifactsAlgorithms[ INFO ] Computer Science [cs]0206 medical engineeringHeart rateCardiology[INFO] Computer Science [cs]010309 opticsMotionDatabases0103 physical sciences[INFO]Computer Science [cs]Heart rate measurement methodPhotoplethysmographyBiomedical measurementLighting[SDV.IB] Life Sciences [q-bio]/BioengineeringArtifact (error)Digital camerasMAHNOB-HCI databasebusiness.industry020601 biomedical engineeringMotion artifacts[SDV.IB.IMA] Life Sciences [q-bio]/Bioengineering/ImagingFace (geometry)FaceState (computer science)Artificial intelligencebusiness
researchProduct

Photoplethysmography for bovine heat detection: the preliminary results

2020

In this study, we applied photoplethysmography (PPG) as an alternative, convenient, and affordable method for bovine heat detection. Heat detection is an essential part of effective herd reproduction management. Currently, there are many different heat detection techniques, but they can be ineffective or impractical to use. Since heat affects local vulvar blood circulation (resulting in swelling and erythema), photoplethysmography could represent an affordable alternative to detect this bovine phenomenon. In this study, we enrolled 20 animals in heat and other stages of the bovine reproduction cycle. We analyzed the PPG signal in terms of baseline (DC component), power, kurtosis, and erythe…

ErythemaSignal quality indexErythema Index01 natural sciences010309 optics03 medical and health sciencesEstrusHeat detectionPhotoplethysmogram0103 physical sciencesMedicinePulse oximeterSignal quality indexPhotoplethysmography030304 developmental biology2. Zero hunger0303 health sciencesKurtosisbusiness.industryCowMeasurement siteBlood circulation:NATURAL SCIENCES::Physics::Atomic and molecular physics [Research Subject Categories]sense organsmedicine.symptomHeat detectionbusinessBiomedical engineering
researchProduct

A study on the effect of contact pressure during physical activity on photoplethysmographic heart rate measurements

2020

Heart rate (HR) as an important physiological indicator could properly describe global subject&rsquo

Future studies0206 medical engineeringheart rate (HR)Physical activityPhysical exercise02 engineering and technologylcsh:Chemical technology01 natural sciencesBiochemistrySignalContact force Contact pressure Heart rate (HR) Heart rate reliability Heart rate signal Photoplethysmography (PPG) PPG accuracy PPG sensor WearablesArticleAnalytical ChemistryPPG accuracysymbols.namesakeWearable Electronic Devicesphotoplethysmography (PPG)Heart RateHeart rateSettore ING-IND/12 - Misure Meccaniche E TermicheMedicineheart rate reliabilityHumanslcsh:TP1-1185Electrical and Electronic EngineeringPhotoplethysmographyInstrumentationExercisecontact pressureheart rate signalbusiness.industry010401 analytical chemistrySignal Processing Computer-Assisted020601 biomedical engineeringAtomic and Molecular Physics and OpticsPearson product-moment correlation coefficient0104 chemical sciencesIntensity (physics)PPG sensorwearablessymbolssense organsbusinesscontact forceContact pressureBiomedical engineering
researchProduct

Comparison of region of interest segmentation methods for video-based heart rate measurements

2018

International audience; Conventional contact photoplethysmography (PPG) sensors are not suitable in situations of skin damage or when unconstrained movement is required. As a consequence, remote photoplethysmography (rPPG) has recently emerged because it provides remote physiological measurements without expensive hardware and improves comfort for long-term monitoring. RPPG estimation methods use the spatially averaged RGB values of pixels in a Region Of Interest (ROI) to generate a temporal RGB signal. The selection of ROI is a critical first step to obtain reliable pulse signals and must contain as many skin pixels as possible with a low percentage of non-skin pixels. In this paper, we ex…

Heart Rate (HR)Computer science[INFO.INFO-TS] Computer Science [cs]/Signal and Image Processing0206 medical engineering02 engineering and technology01 natural sciencesSignal[INFO.INFO-CV] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV][INFO.INFO-TS]Computer Science [cs]/Signal and Image ProcessingRegion of interestPhotoplethysmogramSegmentationComputer visionVideo basedPixelbusiness.industryremote photoplethysmography (rPPG)010401 analytical chemistryPerspective (graphical)[INFO.INFO-CV]Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Region of Interest (ROI)020601 biomedical engineering0104 chemical sciencesRGB color modelArtificial intelligencebusiness
researchProduct

Remote Photoplethysmography for Evaluation of Cutaneous Sensory Nerve Fiber Function

2021

About 2% of the world’s population suffers from small nerve fiber dysfunction, neuropathy, which can result in severe pain. This condition is caused by damage to the small nerve fibers and its assessment is challenging, due to the lack of simple and objective diagnostic techniques. The present study aimed to develop a contactless photoplethysmography system using simple instrumentation, for objective and non-invasive assessment of small cutaneous sensory nerve fiber function. The approach is based on the use of contactless photoplethysmography for the characterization of skin flowmotions and topical heating evoked vasomotor responses. The feasibility of the technique was evaluated on volunt…

Laser Doppler ImagingPopulationSensationNerve fiber030204 cardiovascular system & hematologylcsh:Chemical technologyBiochemistryArticleAnalytical Chemistry03 medical and health sciencesNerve Fibers0302 clinical medicineremote photoplethysmographyPhotoplethysmogrampain assessmentHumansMedicinelcsh:TP1-1185Electrical and Electronic EngineeringPhotoplethysmographyeducationInstrumentationSkinneuropathic paineducation.field_of_studyVasomotorbusiness.industryCutaneous nervecutaneous perfusioncutaneous flowmotionstopical heatingAtomic and Molecular Physics and OpticsCutaneous sensory nervemedicine.anatomical_structureNeuropathic painvasomotor responsechronic painbusiness030217 neurology & neurosurgeryBiomedical engineeringSensors
researchProduct

The analysis of blood flow changes under local anesthetic input using non-contact technique

2010

In this work photoplethysmography imaging (PPGI) technique was used to obtain blood flow changes in human skin under regional anesthesia (RA). PPGI was evaluated from video taken by video camera for 26 patients 2 minutes before and immediately after RA, using custom developed software. Results showed that blood flow obtained by PPGI increases immediately after RA effect and the amplitude of PPGI showed correlation with temperature changes in human skin (r=0.8±0.14, p<0.0001). We found that PPGI technique can be usable for non-contact monitoring of quality of RA.

Local anestheticmedicine.drug_classRegional anesthesiabusiness.industryRemote patient monitoringPhotoplethysmogramAnesthesiamedicinePlethysmographBlood flowbusinessBiomedical engineering2010 3rd International Conference on Biomedical Engineering and Informatics
researchProduct