Search results for "Plethysmography"

showing 10 items of 84 documents

A validity and reliability study of Conditional Entropy Measures of Pulse Rate Variability

2019

In this work, we present the feasibility to use a simpler methodological approach for the assessment of the short-term complexity of Heart Rate Variability (HRV). Specifically, we propose to exploit Pulse Rate Variability (PRV) recorded through photoplethysmography in place of HRV measured from the ECG, and to compute complexity via a linear Gaussian approximation in place of the standard model-free methods (e.g., nearest neighbor entropy estimates) usually applied to HRV. Linear PRV-based and model-free HRV-based complexity measures were compared via statistical tests, correlation analysis and Bland-Altman plots, demonstrating an overall good agreement. These results support the applicabil…

020205 medical informaticsComputer scienceEntropy0206 medical engineeringValidity02 engineering and technologySettore ING-INF/01 - ElettronicaElectrocardiographyPulse Rate Variability (PRV)Heart RatePhotoplethysmogram0202 electrical engineering electronic engineering information engineeringHumansEntropy (information theory)Heart rate variabilityEntropy (energy dispersal)Time seriesPhotoplethysmographyEntropy (arrow of time)Statistical hypothesis testingConditional entropyEntropy (statistical thermodynamics)Reproducibility of ResultsHeart Rate Variability (HRV)020601 biomedical engineeringSettore ING-INF/06 - Bioingegneria Elettronica E InformaticacomplexityAlgorithmEntropy (order and disorder)2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
researchProduct

Cinnamon extract inhibits allergen-specific immune responses in human and murine allergy models.

2019

Background Ceylon cinnamon has been shown to possess anti-inflammatory properties in many diseases including allergic inflammation. Objective The aim of this study was to analyse in more detail the effects of cinnamon extract (CE) and its major compounds p-cymene and trans-cinnamaldehyde (CA) on allergen-specific immune responses in vitro and in vivo. Methods Therefore, monocyte-derived mature dendritic cells (DC) from grass or birch pollen allergic donors were pulsed with the respective allergen in the presence or absence of CE, p-cymene, CA or the solvent ethanol and co-cultured with autologous CD4+ T cells. Furthermore, basophil activation test was performed with or without CE or ethanol…

0301 basic medicineCD4-Positive T-LymphocytesHypersensitivity ImmediateAllergyCinnamomum zeylanicumOvalbuminT cellImmunologyPharmacologyImmunoglobulin Emedicine.disease_causePoaceaeAllergic inflammationDermatitis Atopic03 medical and health sciencesMice0302 clinical medicineAllergenImmune systemIn vivomedicineRespiratory HypersensitivityImmunology and AllergyAnimalsHumansAcroleinBetulaCell ProliferationPlethysmography Whole BodyMice Inbred BALB CbiologyChemistryPlant ExtractsRhinitis Allergic SeasonalDendritic Cellsmedicine.diseaseCoculture TechniquesBasophilsBasophil activationDisease Models Animal030104 developmental biologymedicine.anatomical_structure030228 respiratory systembiology.proteinCymenesCytokinesPollenClinical and experimental allergy : journal of the British Society for Allergy and Clinical ImmunologyREFERENCES
researchProduct

Adaptive scheduling of acceleration and gyroscope for motion artifact cancelation in photoplethysmography

2022

Background and objective: Recently, various algorithms have been introduced using wrist-worn photo-plethysmography (PPG) to provide high accuracy of instantaneous heart rate (HR) estimation, including during high-intensity exercise. Most studies focus on using acceleration and/or gyroscope signals for the motion artifact (MA) reference, which attenuates or cancels out noise from the MA-corrupted PPG signals. We aim to open and pave the path to find an appropriate MA reference selection for MA cancelation in PPG.Methods: We investigated how the acceleration and gyroscope reference signals correlate with the MAs of the distorted PPG signals and derived both mathematically and experimentally a…

Adaptive motion artifact reference selectionInstantaneous heart rate (HR)Gyroscope signalAccelerationSignal Processing Computer-AssistedHealth InformaticsSettore ING-INF/01 - ElettronicaComputer Science ApplicationsAcceleration signalMotionHeart RateSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaReflectance-type photoplethysmography (PPG)PhotoplethysmographyArtifactsAlgorithmsSoftwareComputer Methods and Programs in Biomedicine
researchProduct

Clinical-anamnestic and instrumental data in outpatients suffering from venous disease

1995

The authors studied 200 consecutive outpatients with symptoms due to venous disease of the lower limbs. All the patients underwent anamnestic, clinical and instrumental evaluation (c.w. Doppler velocimetry and strain-gauge plethysmography). The results of this study showed that some anamnestic and clinical data are significantly related to venous disease detected by instrumental techniques. The superficial and deep vein hypertension were, instead, correlated to oral contraceptive use.

AdultAged 80 and overMaleLegSettore MED/09 - Medicina InternaAdolescentMiddle AgedSettore MED/11 - Malattie Dell'Apparato CardiovascolarePlethysmographyAdolescent Adult Aged Aged 80 and over Blood Flow Velocity Contraceptives Oral/adverse effects Female Humans Hypertension/chemically induced Laser-Doppler Flowmetry Leg/blood supply Male Medical History Taking Middle Aged Morbidity Outpatients* Phlebitis/diagnosis Phlebitis/epidemiology Phlebitis/etiology* Plethysmography Pregnancy Retrospective Studies Risk FactorsPregnancyRisk FactorsHypertensionOutpatientsLaser-Doppler FlowmetryHumansFemaleMorbidityMedical History TakingPhlebitisBlood Flow VelocityAgedContraceptives OralRetrospective Studies
researchProduct

Optical noninvasive monitoring of skin blood pulsations

2005

Time-resolved detection and analysis of skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. Single- and multiple-channel PPG concepts are discussed. Simultaneous data flow from several locations on the human body allows us to study heartbeat pulse-wave propagation in real time and to evaluate vascular resistance. Portable single-, dual-, and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The prototype devices have been clinically studied, and their potential for monitoring heart arrh…

AdultMaleAdolescentHeartbeatMaterials Science (miscellaneous)Pulsatile flowArterial Occlusive DiseasesBlood volumeSensitivity and SpecificityIndustrial and Manufacturing EngineeringOpticsData acquisitionArterial occlusionsHeart RatePhotoplethysmogrammedicineAnimalsHumansDiagnosis Computer-AssistedBusiness and International ManagementPhotoplethysmographySkinFrequency filteringbusiness.industryReproducibility of ResultsEquipment DesignEquipment Failure Analysismedicine.anatomical_structurePulsatile FlowVascular resistanceFemalesense organsbusinessAlgorithmsBlood Flow VelocityBiomedical engineeringApplied Optics
researchProduct

Sulodexide and the microcirculatory component in microphlebopathies.

1992

A double-blind, placebo-controlled study was carried out in 36 patients, aged 30 to 50 years, to evaluate the effectiveness of oral sulodexide in the treatment of chronic venous insufficiency due to idiopathic varices. Patients were allocated at random to receive either oral sulodexide as 2 capsules (each containing 250 lipoproteinolipase releasing units) twice daily or 2 identical placebo capsules twice daily over a period of 45 days. Using strain gauge plethysmographic data, assessments were made of the microcirculatory effects of treatment by calculating the coefficient of capillary filtration from measurements made on both legs of each patient on entry and after 30 and 45 days of treatm…

AdultMaleChronic venous insufficiencymedicine.drug_classHemodynamicsAdministration OralPlaceboMicrocirculationDouble-Blind MethodmedicinePlethysmographHumansGlycosaminoglycansHypolipidemic Agentsbusiness.industryAnticoagulantGeneral MedicineMiddle Agedmedicine.diseaseSulodexidePlethysmographyVenous InsufficiencyAnesthesiaChronic DiseaseFemalebusinessVaricesCurrent medical research and opinion
researchProduct

Low relative resting metabolic rate and body weight gain in adult Caucasian Italians

2005

OBJECTIVE: To investigate the relationship between resting metabolic rate (RMR) and subsequent changes in body size and degree of fatness in a group of adult Caucasian Italians. DESIGN: Prospective, longitudinal, observational study. SUBJECTS: In total, 155 subjects (72 males and 83 females, age range: 18–55 y; BMI: 17.5–63.4 kg/m2) were evaluated. In total, 43 (26 m and 17 f; BMI: 28.971.1 kg/m2, mean7s.e.m.) of them were reassessed 10–12 y later. MEASUREMENTS: Anthropometric and body composition (bioimpedance analysis) parameters and RMR (indirect calorimetry) were taken at baseline and after 10–12 y. RESULTS: Subjects (15 m, 8 f) who gained body weight (arbitrarily defined as a change in…

AdultMaleGerontologyAdolescentEndocrinology Diabetes and MetabolismMedicine (miscellaneous)Weight GainBody weightBody Mass IndexAnimal sciencemedicineHumansPlethysmographPlethysmography ImpedanceProspective StudiesProspective cohort studyNutrition and DieteticsAnthropometrybusiness.industryobesità spesa energetica rischio obesitàCalorimetry IndirectMiddle AgedAnthropometrymedicine.diseaseObesityItalyBasal metabolic rateBody CompositionFemaleBasal Metabolismmedicine.symptomEnergy MetabolismbusinessBody mass indexWeight gainFollow-Up Studies
researchProduct

Cardiovascular effects of impulse noise, road traffic noise, and intermittent pink noise at LAeq = 75 dB, as a function of sex, age, and level of anx…

1992

In a previous paper, in which the experimental conditions of the present research are fully described (Parrot et al., this issue), heart rate (HR) was studied in 60 male and in 60 female subjects in response to a pile-driver noise (P), a gunfire noise (G), a road traffic noise (T), and an intermittent pink noise (R), all noises being emitted at the same LAeq = 75 dB for 15 min. Digital pulse level (PL) responses were concomitantly surveyed by the use of pulse oximetry, allowing continuous arterial oxygen saturation (SaO2) readings. An index of pulse reactivity (PRI) could be calculated. Arterial blood pressure was measured 7 times from the beginning to the end of each trial. At rest, within…

AdultMalemedicine.medical_specialtyAdolescentHemodynamicsBlood PressureAudiologyAnxietyPink noiseImpulse noiseHeart RateOccupational ExposureHeart rateAdaptation PsychologicalmedicineHumansHabituation Psychophysiologicmedicine.diagnostic_testbusiness.industryPulse (signal processing)Public Health Environmental and Occupational HealthHemodynamicsMiddle AgedSurgeryOccupational DiseasesPlethysmographyNoisePulse oximetryBlood pressureNoise TransportationNoise OccupationalFemaleVascular ResistancebusinessArousalInternational archives of occupational and environmental health
researchProduct

Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.

2014

Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…

AdultMalemedicine.medical_specialtyBiomedical EngineeringNormal DistributionHemodynamicsBiomaterialsInternal medicinePhotoplethysmogrammedicineHumansPhotoplethysmographyReactive hyperemiaHemodynamicsBlood flowArteriesmedicine.diseaseArterial occlusionAtomic and Molecular Physics and OpticsHealthy VolunteersElectronic Optical and Magnetic MaterialsFemoral Arterymedicine.anatomical_structureBlood pressureAnesthesiaCardiologyVascular resistanceArterial stiffnessFemaleVascular ResistanceJournal of biomedical optics
researchProduct

Investigation into isoprenaline resistance in patients with obstructive lung disease

1974

12 patients with chronic obstructive lung disease have been studied in an investigation regarding the causes of resistance to isoprenaline. The effects of repeated intravenous doses of 10 µg isoprenaline were assessed by cross over comparison before and after infusions of isoprenaline and a placebo; the infusions lasted for 35 to 40 min and the amount of isoprenaline infused was 0.5 µg/min. Total resistance, thoracic gas volume (whole-body plethysmography) and heart rate (ECG) were measured. No decrease in bronchospasmolytic or positive chronotopic effects on single isoprenaline injections could be demonstrated after prolonged infusions of isoprenaline.

AdultMalemedicine.medical_specialtyDrug ResistanceDrug resistancePlaceboPlacebosElectrocardiographyHeart RateIsoprenalineInternal medicineHeart ratemedicineHumansPlethysmographInfusions ParenteralPharmacology (medical)Lung Diseases ObstructiveAgedPlethysmography Whole BodyAsthmaPharmacologyAnalysis of VarianceClinical Trials as Topicbusiness.industryAirway ResistanceIsoproterenolGeneral MedicineMiddle Agedmedicine.diseaseStimulation ChemicalObstructive lung diseaseAirway ObstructionBronchodilatationAnesthesiaInjections IntravenousCardiologyFemalebusinessmedicine.drugEuropean Journal of Clinical Pharmacology
researchProduct