Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: evaluation of applicator attenuation and superposition approximation effe…
2004
The purpose of this study is to calculate the dose rate distribution for the Amersham Cs-137 pellet source used in brachytherapy with the Selectron low-dose-rate remote afterloading system in gynaecological applications using the Monte Carlo code GEANT4. The absolute dose rate distribution for the pellet source was obtained and presented as a one-dimensional absolute dose rate table as well as in the Task Group 43 dose-calculation formalism. In this study, excellent agreement was found between the point source theoretical model using fitted polynomial values and Monte Carlo calculations of the dose rate distribution for the pellet source. A comparison study was also made between the dose ra…
Constraining the neutrino emission of gravitationally lensed Flat-Spectrum Radio Quasars with ANTARES data
2014
This paper proposes to exploit gravitational lensing effects to improve the sensitivity of neutrino telescopes to the intrinsic neutrino emission of distant blazar populations. This strategy is illustrated with a search for cosmic neutrinos in the direction of four distant and gravitationally lensed Flat-Spectrum Radio Quasars. The magnification factor is estimated for each system assuming a singular isothermal profile for the lens. Based on data collected from 2007 to 2012 by the ANTARES neutrino telescope, the strongest constraint is obtained from the lensed quasar B0218+357, providing a limit on the total neutrino luminosity of this source of 1.08×10^46 erg s-1. This limit is about one o…
INTEGRAL/SPI ground calibration
2003
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral resolution and the angular resolution. Absolute determination of the effective area has been obtained from simulations and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on the optical axis, the spectral resolution ~2.3 keV. The angular resolution is better than 2.5 deg and the source separation capability about 1 deg. Some temperature dependant parameters will require permanent in-flight calibration.
Receiving water body quality assessment: an integrated mathematical approach applied to an Italian case study
2011
This study presents a basin-scale approach to the analysis of receiving water body quality considering both point and non-point pollution sources. In particular, this paper describes an extensive data gathering campaign carried out in the Nocella catchment, which is an agricultural and semi-urbanised basin located in Sicily, Italy. Two sewer systems, two wastewater treatment plants and a river reach were monitored during both dry and wet weather periods. A mathematical model of the entire integrated system was also created. Specifically, a detailed modelling approach was developed by employing three well known models: Storm Water Management Model, GPS-X and Soil and Water Assessment Tool. T…
Heavy metals in urban soils: a case study from the city of Palermo (Sicily), Italy.
2002
Concentrations of V, Mn, Cd, Zn, Ni, Cr, Co, Cu, Pb, Hg and Sb were measured on 70 topsoil samples collected from green areas and parks in the city of Palermo (Sicily) in order to: (1) assess the distribution of these heavy metals in the urban environment; (2) discriminate natural and anthropic contributions; and (3) identify possible sources of pollution. Mineralogy, physico-chemical parameters, and major element contents of the topsoils were determined to highlight the influence of 'natural' features on the heavy metal concentrations and their distribution. Medians of Pb, Zn, Cu and Hg concentrations of the investigated urban soils are 202, 138, 63 and 0.68 mgkg(-1), respectively. These v…
Quantification of diffuse and concentrated pollutant loads at the watershed-scale: an Italian case study
2009
In this study, diffuse and point source pollutant loads were evaluated using an Italian case study: the Nocella catchment, which has been subject to extensive monitoring. The Nocella catchment is located in Sicily (Italy) and has an area of about 60 km2. The river receives wastewater and stormwater from two urban areas drained by combined sewers. The two sewer systems, two wastewater treatment plants and a river reach were monitored during both dry and wet weather periods. Thereafter, an integrated catchment-scale model was applied to simulate point pollutant sources, i.e., pollution coming from the urban drainage system, and nonpoint pollutant sources, i.e., pollution coming from agricultu…
Additional Evidence for a Pulsar Wind Nebula in the Heart of SN 1987A from Multiepoch X-Ray Data and MHD Modeling
2022
Since the day of its explosion, supernova (SN) 1987A has been closely monitored to study its evolution and to detect its central compact relic. In fact, the formation of a neutron star is strongly supported by the detection of neutrinos from the SN. However, besides the detection in the Atacama Large Millimeter/submillimeter Array (ALMA) data of a feature that is compatible with the emission arising from a proto-pulsar wind nebula (PWN), the only hint for the existence of such elusive compact object is provided by the detection of hard emission in NuSTAR data up to ~ 20 keV. We report on the simultaneous analysis of multi-epoch observations of SN 1987A performed with Chandra, XMM-Newton and…
EVALUATION OF DIFFUSE AND CONCENTRATED POLLUTION AT WATERSHED SCALE
2009
The study presents an integrated approach in order to analyse and quantify pollution dynamics at basin scale depending on concentrated and diffuse sources. More specifically, an integrated model for urban drainage system has been exploited in order to simulate the complex sewer network - wastewater treatment plant and receiving water body. Moreover, a quali-quantitative model has been developped in order to simulate the non-point sources pollutant (agricultural and zoo-technical) in term of water river discharges and nutrient, produced from the wash off of soils. Finally, different models have been coupled in order to reconstruct the whole pollutant load for the receiving water body and to …
TheINTEGRALspectrometer SPI: performance of point-source data analysis
2005
The performance of the SPI point-source data analysis system is assessed using a combination of simulations and of observations gathered during the first year of INTEGRAL operations. External error estimates are derived by comparing source positions and fluxes obtained from independent analyses. When the source detection significance provided by the SPIROS imaging reconstruction program increases from ∼10 to ∼100, the errors decrease as the inverse of the detection significance, with values from ∼10 to ∼1 arcmin in positions, and from ∼10 to ∼1 per cent in relative flux. These errors are dominated by Poisson counting noise. Our error estimates are consistent with those provided by the SPIRO…
Poisson Regression with Change-Point Prior in the Modelling of Disease Risk around a Point Source
2003
Bayesian estimation of the risk of a disease around a known point source of exposure is considered. The minimal requirements for data are that cases and populations at risk are known for a fixed set of concentric annuli around the point source, and each annulus has a uniquely defined distance from the source. The conventional Poisson likelihood is assumed for the counts of disease cases in each annular zone with zone-specific relative risk and parameters and, conditional on the risks, the counts are considered to be independent. The prior for the relative risk parameters is assumed to be piecewise constant at the distance having a known number of components. This prior is the well-known cha…