Search results for "Porous medium"
showing 10 items of 164 documents
Thermally induced structural modifications and O2 trapping in highly porous silica nanoparticles
2014
Abstract In this work we investigate by Raman spectroscopy the effect of isochronal (2 h) thermal treatments in air in the temperature range 200–1000 °C of amorphous silicon dioxide porous nanoparticles with diameters ranging from 5 up to 15 nm and specific surface 590–690 m2/g. Our results indicate that the amorphous structure changes similarly to other porous systems previously investigated, in fact superficial SiOH groups are removed, Si–O–Si linkages are created and the ring statistic is modified, furthermore these data evidence that the three membered rings do not contribute significantly to the Raman signal detected at about 495 cm−1. In addition, after annealing at 900 and 1000 °C we…
Acoustic methods for measuring the porosities of porous materials incorporating dead-end pores
2013
International audience; The acoustic properties of porous materials containing dead-end (DE) pores have been proposed by Dupont et al. [J. Appl. Phys. 110, 094903 (2011)]. In the theoretical description, two physical parameters were defined (the dead-end porosity and the average length of the dead-end pores). With the knowledge of the open porosity (measured with non-acoustic methods), and the measurement of kinematic porosity (also called the Biot porosity in this article), it is possible to deduce the dead-end porosity. Two acoustic methods for measuring the Biot porosity for a wide range of porosities are proposed. These methods are based on acoustic transmission and on the low and high …
Intrusion of nonwetting liquid in paper
2007
The saturation curve of a sample of paper board was measured with mercury-intrusion porosimetry, and the three-dimensional structure of its pore space was determined by x-ray tomographic imaging. Ab initio numerical simulation of intrusion on the tomographic reconstruction, based on the lattice-Boltzmann method, was in excellent agreement with the measured saturation curve. A numerical invasion-percolation simulation in the same tomographic reconstruction showed good agreement with the lattice-Boltzmann simulation. The access function of the sample, determined from the saturation curve and the pore-throat distribution determined from the tomographic reconstruction, indicated that the ink-bo…
Convective Roll Instabilities of Vertical Throughflow with Viscous Dissipation in a Horizontal Porous Layer
2009
Published version of an article from the journal: Transport in Porous Media. The original publication is available at Spingerlink. http://dx.doi.org/10.1007/s11242-009-9417-y The vertical throughflow with viscous dissipation in a horizontal porous layer is studied. The horizontal plane boundaries are assumed to be isothermal with unequal temperatures and bottom heating. A basic stationary solution of the governing equations with a uniform vertical velocity field (throughflow) is determined. The temperature field in the basic solution depends only on the vertical coordinate. Departures from the linear heat conduction profile are displayed by the temperature distribution due to the forced con…
Linear instability of mixed convection of cold water in a porous layer induced by viscous dissipation
2009
Accepted version of an article published in the journal: International Journal of Thermal Sciences, Elsevier Published version available on Science Direct: http://dx.doi.org/10.1016/j.ijthermalsci.2008.06.012 An analysis of linear stability of the stationary laminar Darcy flow in a horizontal porous layer is performed. The porous layer is saturated with cold water. The upper plane boundary is assumed to be subject to heat transfer with finite conductance to an environment at the temperature of maximum density of cold water. The lower plane boundary is adiabatic. Convective instabilities are caused by flow viscous dissipation, inducing a basic temperature distribution that decreases in the u…
Adsorbents and columns in analytical high-performance liquid chromatography: A perspective with regard to development and understanding
2012
A brief historical survey is presented on the evaluation of silica adsorbents in analytical HPLC. The theory of analytical HPLC is mostly still being based on the height equivalent to a theoretical plate concept and the van Deemter equation that was derived from gas phase adsorption involving a linear adsorption isotherm and fast mass transfer kinetics. One can obviously wonder whether the use of the van Deemter equation is relevant and valid for the evaluation of the performance of HPLC systems, where most often the liquid solutes involve charged molecules in electrolytes and in very many cases the adsorbates are macromolecules having diffusion coefficients of small magnitude. Instead of t…
Water Adsorption in Flexible Gallium-Based MIL-53 Metal–Organic Framework
2014
Understanding the adsorption of water in metal–organic frameworks (MOF), and particularly in soft porous crystals, is a crucial prerequisite before considering MOFs for industrial applications. We report here a joint experimental and theoretical study on the behavior of a gallium-based breathing MOF, Ga-MIL-53, upon water adsorption. By looking at the energetics and thermodynamics of Ga-MIL-53, we demonstrate why it behaves differently from its sibling Al-MIL-53, showing a different phase at room temperature (a nonporous phase) and the presence of a hydrated narrow-pore structure at gas saturation pressure. Moreover, we present a complete water vapor pressure vs temperature phase diagram of…
Bleach interference in forensic luminol tests on porous surfaces: more about the drying time effect.
2009
As criminals try to avoid leaving clues at the scene of a crime, bloodstains are often washed away, but fortunately for investigators, they are difficult to eliminate completely. Porous surfaces easily retain blood traces, which are sometimes invisible to the naked eye. The reagent of choice for detecting latent blood traces on all types of surfaces is luminol, but its main disadvantage is a high degree of sensitivity to oxidising contaminants in the blood sample. If household bleach is used to clean bloodstains, presumptive tests are invalidated. Hypochlorites, however, are known to be unstable and deteriorate over time, and this feature could be of help in preventing household bleach-indu…
Saturated Soil Hydraulic Conductivity
2016
This chapter deals primarily with field measurement of saturated soil hydraulic conductivity, K fs . Well or borehole permeameter techniques, specifically developed for subsurface soil measurements above the water table, are initially illustrated. Particular attention is paid to establishment of steady flow under constant head in an uncased borehole, widely developed both theoretically and experimentally in the last 30 years. Situations involving cased boreholes, transient flow, or falling head processes are then described. These variants have received a renewed interest in the last few years. New data analysis procedures have been proposed and this circumstance allows us to obtain subsurfa…
Water capillary absorption in porous media in different wettability conditions studied by Quantitative MRI and X-ray CT
2007
X-ray computed tomography (CT) and magnetic resonance imaging (MRI) have been successfully applied to study both the capillary properties of several samples of Lecce stone and the performances of treatments used for protection and conservation of historical stone artifacts. The presence of water inside the sample may be visualized by both MRI and X-ray CT. For the treated samples, the different dynamics of water absorption gives indirectly the efficacy of the polymer in the rock.