Search results for "Power Distribution"
showing 10 items of 57 documents
Analyzing the feasibility of time correlated spectral entropy for the assessment of neuronal synchrony
2016
In this paper, we study neuronal network analysis based on microelectrode measurements. We search for potential relations between time correlated changes in spectral distributions and synchrony for neuronal network activity. Spectral distribution is quantified by spectral entropy as a measure of uniformity/complexity and this measure is calculated as a function of time for the recorded neuronal signals, i.e., time variant spectral entropy. Time variant correlations in the spectral distributions between different parts of a neuronal network, i.e., of concurrent measurements via different microelectrodes, are calculated to express the relation with a single scalar. We demonstrate these relati…
A modified IEEE 802.11 protocol for reliable data transmission in automated power distribution systems
2009
A high level of power quality in distribution networks is obtained by means of a diagnostic software, that establishes on-line the status of the network, by elaborating the measured data. An efficient telecommunication system is necessary, from whose reliability depends the security of the timely interventions on the network in case of fault. In the paper, after a brief examination of the diagnostic method, the telecommunication system is examined. The WiFi system has been considered most suitable, for its economy, for the diagnostic service, besides it is not suitably reliable for how it is managed by the IEEE 802.11 protocol for this application. In this work a new protocol derived by the…
Faults identification, location and characterization in electrical systems using an analytical model-based approach
2005
The start of the electrical energy market has encouraged distributors to make new investments at distribution level so as to attain higher quality levels. The service continuity is one of the aspects of greater importance in the definition of the quality of the electrical energy. For this reason, the research in the field of fault diagnostic for distribution systems is spreading ever more. This paper presents a novel methodology to identify, locate and characterize the faulty events in the electrical distribution systems. The methodology can be extended to all types of faulty events and is applicable to reconfigurable systems. After having described the guidelines of the methodology, the Au…
Real-Time Power Flow Monitoring and Control System for Microgrids Integration in Islanded Scenarios
2019
This article presents an enhanced system for real-time power flow monitoring and control (PFMC) for microgrids integration in medium-voltage (MV) distribution networks. The developed solution includes both system architecture and the monitoring and control algorithms, and it has low implementation and installation costs. It is based on the use of hardware and software solutions previously proposed by the authors, i.e., a distributed measurement, a control and communication architecture, and a supervisory control and data acquisition (SCADA) software, which have been enhanced and integrated for the considered application. The SCADA implements a load flow (LF) algorithm for real-time power fl…
Assessing fat-tailed sequential forecast distributions for the Dow-Jones index with logarithmic scoring rules
2007
We use the logarithmic scoring rule for distributions to assess a variety of fat-tailed sequential forecasting distributions for the Dow-Jones industrial stock index from 1980 to the present. The methodology applies Bruno de Finetti''s contributions to understanding how to compare the quality of different coherent forecasting distributions for the same sequence of observations, using proper scoring rules. Four different forms of forecasting distributions are compared: a mixture Normal, a mixture of convex combinations of three Normal distributions, a mixture exponential power distribution, and a mixture of a convex combination of three exponential power distributions. The mixture linear com…
Optimal Operating Point Calculation for Medium Voltage Distribution Systems
2007
The paper deals with the calculation of the optimal working point of a distribution system, equipped with several distributed generators, able to operate also autonomously, i.e. disconnected from the main grid. When connected to the main grid, it appears in general convenient to assign the slack bus role to the bus that represents such a connection. The problem becomes more complex when maximum power transfer constraints through the connection must be taken into account. The adequate slack bus treatment is even more important when the optimal operating condition must refer to the condition subsequent to an intentional or unintentional disconnection from the main grid. The paper presents an …
Eco-sustainable energy and environmental strategies in design for recycling: the software “ENDLESS”
2003
Abstract This paper describes a model, named “ENDLESS”, useful to address the design process towards more eco-compatible solutions. In particular, this tool can support the designer in the choice of the product with an higher recyclability potential from a set of different alternatives. The model takes into consideration a Multi-Attribute Decision-Making method and allows calculating a “Global Recycling Index” (GRI) starting from a set of energy, environmental, technical and economic indicators. A weight is assigned to each parameter following the experience of the designer; a sensitivity analysis is then performed to state how the different assumptions can affect the final results. The mod…
Currents Distribution During a Fault in an MV Network: Methods and Measurements
2016
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighboring substations. In this paper the problem of fault current distribution is introduced, the tes…
Secondary substation power line communications for medium voltage smart grids
2012
In this paper a performance analysis is carried out, in order to evaluate the possibility to employ power line communication (PLC) between secondary substations of a medium voltage (MV) distribution networks in a smart grid. The study is focused on the analysis of PLC technologies and the evaluation of the influence quantities on the communication performance in the most common case of by-pass connection at MV bus-bars of secondary substations. Different quantities have been analyzed as modulation techniques, requested bandwidth and bitrate, coupling device and system attenuation versus frequency in order to find the best solution for a reliable communication system. A complete model of a r…
Experimental investigation on PLC signal crossing of power transformers
2014
In this work the use of PLC in MV-LV networks is investigated, by means of experimental tests in the case of a two-ways MV/LV communication between two secondary substations. The two substations are connected by a MV overhead power line. Moreover each substation has a by-pass connection at MV bus-bars and a MV/LV power transformer. A ST7580 transceiver is used to inject the communication signal. The transceiver is embedded in a new interface device developed by the authors. In the paper the communication issues are introduced and some experimental tests are presented and discussed. Such tests have been carried out in the presence of voltage net, i.e. 24 kV, with the aim to verify the possib…