Search results for "Power Distribution"
showing 10 items of 57 documents
The Sequential Switching Shunt Maximum Power Regulator and its Application in the Electric Propulsion System of a Spacecraft
2007
This paper describes a baseline solution of a Power Conditioning and Distribution Unit (PCDU) for Electrical Propulsion (EP) systems. The solution adopted uses two high efficiency, low-mass power regulators; a solar array regulator (SAR) based on the classical Sequential Switching Shunt Regulator with Maximum Power Point Tracking (MPPT) capability followed by a step-up converter to achieve the desired regulated bus voltage. This paper focuses on the first part of the PCDU, the Sequential Switching Shunt Maximum Power Regulator (S3MPR). This electrical architecture has been adapted and recently proposed for the Electric Propulsion power system of the European and Japanese Mercury Mission (Be…
Lighting in educational environments: An example of a complete analysis of the effects of daylight and electric light on occupants
2013
Abstract Light induces not only visual responses but also non-visual effects, indeed it affects performance, mood, attention and influences the synchronization of the biological clock. Duration, timing, intensity and the spectral power distribution of the light that reaches the eyes can have influence on human circadian rhythm and consequently on health. Given the important impact of the non-visual responses on people wellbeing, developing a model that allows lighting designers to predict them is a fundamental goal. In this paper a case study is reported: a series of measurements were carried out in a University classroom in order to study daylight and electric light characteristics and als…
A novel approach to current transformer characterization in the presence of harmonic distortion
2009
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…
New Measurement Procedure for Load Flow Evaluation in Medium Voltage Smart Grids
2013
The aim of this paper is to present a new approach for the medium voltage (MV) distribution network load flow analysis, mainly based on power measurement at the low voltage (LV) level of MV/LV distribution substations. This allows to use measurement instruments, usually already installed in the secondary substations, thus achieving an equally reliable measurement system with a lower cost compared to measurements at the MV side. The new approach can be applied using a proper communication system to collect the nodal measurements and an iterative algorithm based on ladder iterative technique (LIT) to compute the load flow. The validity of this method is presented and discussed on the basis of…
Optimal Electrical Distribution Systems Reinforcement Planning Using Gas Micro Turbines by Dynamic Ant Colony Search Algorithm
2007
Distribution systems management is becoming an increasingly complicated issue due to the introduction of new energy trading strategies and new technologies. In this paper, an optimal reinforcement strategy to provide reliable and economic service to customers in a given time frame is investigated. In the new deregulated energy market and considering the incentives coming from the political and economical fields, it is reasonable to consider distributed generation (DG) as a viable option for systems reinforcement. In the paper, the DG technology is considered as a possible solution for distribution systems capacity problems, along several years. Therefore, compound solutions comprising the i…
Distraplan: a flexible tool for strategical planning of electrical distribution systems considering distributed generation.
2005
The paper here presented describes and shows DISTRAPLAN (Distribution Strategical Planning), software tool for strategical planning of distribu tion networks at Medium and Low voltage. The software aims at the identification and comparison of network configur ations, optimized in the long term with identification of special features in relation to the main technical-economical-environmental aspects, such as: the number of HV/MV and MV/LV substations, total length of the MV and LV lines and relevant sections, maximum required energy and power, instal lation and losses costs, etc. DISTRAPLAN, in both the main procedures into which it is articulated (strategical planning and evaluation of the …
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…
A Simple Method to Assess Loadability of Radial Distribution Networks
2005
This paper proposes a simple method to asses loadability in radial distribution systems. The relevant problem of voltage stability has been dealt with in past times with reference to higher voltage systems for generation and transmission. In more recent papers, the problem has been considered also at distribution level, since the new electrical energy market requirements and the increasing loadings are now more and more influencing these systems. The proposed method is based on a static approach and proceeds by first evaluating the stability indices and then the different loadability factors (related to real, reactive and apparent power). These calculations are carried out by identifying, s…
Technical, Environmental and Economical Aspects of Hybrid Systems Including Renewables and Fuel Cells
2006
In this paper, some configurations including renewables and fuel cells are studied. Technical, environmental and economical aspects are treated in the frame of the EU regulations concerning the ‘emission trading’ issue and the way in which Italy has implemented the relevant EU directive. The study has been carried out considering some architectures including renewables such as photovoltaic and wind with a back up system to increase continuity of supply based on the application of fuel cells and of a hydrogen storage system. Performing several runs with different values of the cost of energy (COE) bought from the network and produced with traditional fuel, it has been observed that, for some…
Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements
2015
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…