Search results for "Power Distribution"
showing 10 items of 57 documents
ATLAS technical coordination expert system
2019
When planning an intervention on a complex experiment like ATLAS, the detailed knowledge of the system under intervention and of the interconnection with all the other systems is mandatory. In order to improve the understanding of the parties involved in an intervention, a rule-based expert system has been developed. On the one hand this helps to recognise dependencies that are not always evident and on the other hand it facilitates communication between experts with different backgrounds by translating between vocabularies of specific domains. To simulate an event this tool combines information from different areas such as detector control (DCS) and safety (DSS) systems, gas, cooling, vent…
Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion
2010
The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…
Characterization of clamp-on current transformers under nonsinusoidal conditions
2009
This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…
Improving the energy efficiency of an islanded distribution network using classical and innovative computation methods
2016
The paper presents the analysis of some potentially suitable actions for reducing the energy losses of an islanded Medium Voltage distribution network, with the aim of improving electricity distribution efficiency. For this purpose, four actions are considered: 1) increasing the network's rated voltage; 2) reactive power compensation through static capacitor banks; 3) reactive power compensation through switchable capacitor banks; 4) installation of distributed photovoltaic (PV) generation. The first two measures are typically taken into account by the distribution system operators and can be examined by means of classical design methods, whereas the latter two more innovative actions are t…
Analysis of spectral irradiance distribution for PV applications at high latitude
2020
The spectral distribution of global tilted irradiance measured in Grimstad, Norway, is analyzed in terms of the average photon energy ( $APE$ ) blue fraction ( $BF$ ) and useful fraction ( $UF$ ). The results based on eight months of recorded data show a general shift of the $APE,\ BF$ , and $UF$ values to higher values than reference AM1.5G spectrum, with 1.63 eV, 0.45, and 0.88 being the average indices, respectively. The statistical coefficient of variation ( $CV$ ) is used to determine the variation of indices. The $CV$ for $APE,\ BF$ , and $UF$ are calculated to be 20.1%, 26.1%, and 25.7%, respectively confirming the earlier findings on $APE$ being a more accurate index for the quantif…
Indoor artificial lighting: Prediction of the circadian effects of different spectral power distributions.
2014
The study presented in this paper aims to evaluate if and how the environment affects the circadian impact of a light source by predicting circadian stimulus (CS) resulting from the exposure to different light scenes, using equations reported in studies by Rea et al. The main findings are: (1) Above 600 lx at eye level the increase of CS is little; (2) Between 50 lx and 200 lx at the eye level an increase of only 50 lx determines a significant increase of CS; (3) Light sources with correlated colour temperatures between 2900 K and 4200 K have similar impacts on the circadian system according to the calculation method used; (4) Even an almost neutral environment affects the circadian impact…
Modelling a proportion response variable using generalised additive models for location scale and shape
2015
In this paper two alternative approaches are proposed to model a response variable Y measured on the interval from zero to one, including both zero and one. The first proposed model employs a flexible four parameter distribution for 0 < Y < 1, for example a logit skew exponential power distribution, inflated by including point probabilities at 0 and 1. The second proposed model is a generalised Tobit model, obtained from a flexible four parameter distribution on (-infinity;+infinity), for example the skew exponential power distribution, by censoring below 0 and above 1. The proposed models are applied to a real data set and compared with current popular models.
Three dimensional reconstruction to visualize atrial fibrillation activation patterns on curved atrial geometry
2021
BackgroundThe rotational activation created by spiral waves may be a mechanism for atrial fibrillation (AF), yet it is unclear how activation patterns obtained from endocardial baskets are influenced by the 3D geometric curvature of the atrium or ‘unfolding’ into 2D maps. We develop algorithms that can visualize spiral waves and their tip locations on curved atrial geometries. We use these algorithms to quantify differences in AF maps and spiral tip locations between 3D basket reconstructions, projection onto 3D anatomical shells and unfolded 2D surfaces.MethodsWe tested our algorithms in N = 20 patients in whom AF was recorded from 64-pole baskets (Abbott, CA). Phase maps were generated by…
Modelling and analysis of the influence of solar spectrum on the efficiency of photovoltaic modules
2021
Abstract The article presents the influence of changes in the solar radiation spectrum distribution on the properties of various photovoltaic modules, with particular emphasis on the scattered component. We compared the relative efficiency of the photovoltaic modules based on various semiconductor absorbers during bright and sunny, and cloudy summer days. Additionally, we presented the impact of the module tilt angle on the magnitude of the surface incident scattered component and on the efficiency of the module. The solar spectra for various weather conditions were estimated using specialised computer programmes,such as SolarSpectrum or SMARTS2, and we present here the validation results f…
A fuzzy-logic based evolutionary multiobjective approach for automated distribution networks management
2004
In this paper, a methodology to treat constrained scheduling problems based on the repeated application of a fuzzy-logic-based multiobjective algorithm is presented. The application domain is that of automated distribution systems management. In particular, the problem of voltage regulation and power loses minimization is here considered. The classical formulation of the problem of optimal control of shunt capacitor banks and under load tap changers, ULTC, located at high voltage/medium voltage (HV/MV) substations has been coupled with the optimal control of tie-switches and capacitor banks on the feeders of a large radially operated meshed distribution system with the aim of attaining mini…