Search results for "Power engineering"
showing 10 items of 126 documents
Vibration signature analysis for rotor broken bar diagnosis in double cage induction motor drives
2013
The paper investigates the diagnosis of rotor broken bars in field oriented controlled (FOC) double cage induction motor drives, using current and vibration signature analysis techniques. The Impact of the closed loop control system cannot be neglected when the detection of asymmetries in the machine are based on the signature analysis of electrical variables. The proposed diagnosis approach is based on optimized use of wavelet analysis by a pre-processing of phase current or axial/radial vibration signals. Thus, the time evolution of the tracked rotor fault components can be effectively analyzed. This paper shows also the relevance of the fault components computed from axial vibration sign…
A two-end traveling wave fault location system for MV cables based on LoRa technology
2017
In this paper a new low cost device is proposed for fault location in power distribution system. The device is part of a system that should include several units installed in couples at the two ends of MV cable lines. Their low cost justifies a widespread installation of these devices, moreover other functionalities could be considered so as to enrich the potential of the system for MV cables monitoring and asset management. The system exploits a two-end traveling wave technique, low complexity and low cost solutions both for the analog front end as well as for the communication infrastructure. A LoRa network is indeed considered as wireless modulation technique perfectly suited when commun…
Effects of double ground faults in Wind Farms collector cables
2015
Medium Voltage collector cables of Wind Farms have metal shields connected to the grounding systems of the towers and of the connection station. Thanks to this bonding, when a ground fault occurs, the fault current splits itself among all the grounding systems of the wind farm, this causing a reduction of the ground potential rise at the fault location. Nevertheless, in presence of double ground faults, very high ground potential rises occur at the two fault locations and safety against electric shock is not always assured. In order to study this issue, the paper presents a model for simulating in a simple way the effects of double ground faults occurring in Medium Voltage collectors of ext…
Development of Diagnostic Systems for the Fault Tolerant Operation of Micro-Grids
2010
The progressive penetration level of Distributed Generation (DG) is destined to cause deep changes in the existing distribution networks no longer considered as passive terminations of the whole electrical system. A possible solution is the realization of small networks, namely the Micro-Grids, reproducing in themselves the structure of the main production and distribution of the electrical energy system. In order to gain an adequate reliability level of the micro-grids the individuation and the management of the faults with the goal of maintaining the micro-grid operation (fault tolerant operation) is quite important. In the present paper after the introduction of the aims of several diagn…
A review of multiple faults diagnosis methods in Voltage Source Inverters
2015
This paper examines, as in short review, the methods of diagnosis of simple and multiple faults on Voltage Source Inverter (VSI). The methods examined here are essentially based on the inspection of the load currents. Some of these diagnosis methods are characterized by low computational effort, other for a better reliability avoiding faultless positive tests. Some solutions are characterized by a share of these benefits while others prefer an enforcement of trustworthiness, in spite of the lower calculation amount. The analysis of the technical literature, certainly, offers a glimpse about the creation of new algorithms and significant advances for the future.
An efficient diagnostic technique for distribution systems based on under fault voltages and currents
2010
Service continuity is one of the major aspects in the definition of the quality of the electrical energy, for this reason the research in the field of faults diagnostic for distribution systems is spreading ever more. Moreover the increasing interest around modern distribution systems automation for management purposes gives faults diagnostics more tools to detect outages precisely and in short times. In this paper, the applicability of an efficient fault location and characterization methodology within a centralized monitoring system is discussed. The methodology, appropriate for any kind of fault, is based on the use of the analytical model of the network lines and uses the fundamental co…
Effects of electrical and mechanical parameters on the transient voltage stability of a fixed speed wind turbine
2011
Abstract In this paper the dynamic behaviour of a wind turbine connected to the grid is examined. The model of the fixed speed wind turbine has been developed with the Simulink simulation tool (Matlab Inc.) It is composed of the induction generator, the shaft system, an aerodynamic model of the wind turbine rotor and the pitch control system. Using this model, a three-phase fault is applied close to the wind turbine and cleared by disconnecting the faulty line. The rigorous implementation of the simulink model allowed the authors to evaluate the exact dependence of various electrical parameters for the induction generator on voltage stability. Furthermore, the effects of wind turbine mechan…
An architecture Wi-fi and GPRS for efficient management of distribution electrical networks
2008
In this paper, a telecommunication infrastructure for faults management is proposed. The complete automation of the electrical energy distribution requires the implementation of suitable data transmission systems able to easily interface with microprocessor based systems and to handle large amount of data. In particular, reliability and speed of the data transmission system are required in the fault diagnosis and post-fault management procedures, in order to guarantee high quality standards. The proposed diagnostic system indeed works by means of a set of intercommunicating MV/LV dasiaintelligent substationspsila. In this paper, after a brief description of the fault diagnostic system, an o…
The Advantages of the Network-based Electronic Teaching Package by the Implementation of English for Specific Purposes Course
2015
Abstract The article analyses the advantages of English for Specific Purposes teaching of the fourth year students majoring in “Electrical and Power Engineering” at National Research Tomsk Polytechnic University by means of the network-based electronic teaching package. This paper analyzes the structural content of the network-based electronic teaching package, shows the key approaches used to develop this tool and focuses on the description of its main components. The conclusions made are based on the results obtained over a three year period (2012-2015) of the network-based electronic teaching package use.
Control of solid-state fault current limiter for DG-integrated distribution systems
2017
Fault current limier (FCL) is a device that limits the system current under fault conditions without disconnecting the system and affecting the power system protection components such as circuit breakers. Many types of FCLs have been proposed to limit the magnitude of the fault current. Solid-state fault current limiters (SSFCLs) can limit the peak value of the fault current by applying several methods, such as controlling the system impedance or controlling the voltage that appears across the fault. In this paper, a new control scheme for the SSFCL circuit is presented. The control method is based on controlling the duty cycle of solid state switches to control the rms value of the system …