Search results for "Power factor"
showing 10 items of 38 documents
Analytical solution for the diffusion of a capacitor discharge generated magnetic field pulse in a conductor
2016
Powerful forces arise when a pulse of a magnetic field in the order of a few tesla diffuses into a conductor. Such pulses are used in electromagnetic forming, impact welding of dissimilar materials and grain refinement of solidifying alloys. Strong magnetic field pulses are generated by the discharge current of a capacitor bank. We consider analytically the penetration of such pulse into a conducting half-space. Besides the exact solution we obtain two simple self-similar approximate solutions for two sequential stages of the initial transient. Furthermore, a general solution is provided for the external field given as a power series of time. Each term of this solution represents a self-sim…
3-Phase grid-connected building integrated photovoltaic system with reactive power control capability
2020
Abstract Recently, a tendency in the growing of grid-connected building integrated photovoltaic (BIPV) systems has been noticed in most countries. Hence, high penetration of PV power into the system network can be observed in many points in the network. This may cause severe problems on the distribution network due to the intermittent nature of PV systems. As a feasible solution, the reactive power capability of voltage source inverter in PV systems can be employed rather than approaching expensive grid infrastructures in the distribution network. The purpose of this study is to implement a 3-phase grid-connected (BIPV) system with reactive power control to regulate the system voltage and i…
Algebraic real-time algorithm for B-Spline sinusoidal pulse width modulation in three phase voltage source inverters.
2008
In this paper a novel algebraic real-time algorithm for implementation of sinusoidal pulse width modulation (SPWM) based on B-spline carriers is introduced and discussed. B-spline functions are used as carrier signals with the aim to to reduce harmonic content of the three phase inverter output voltage. This algorithm eliminates the problem of B-spline recursive evaluation with convolution integrals or convolution sums in digital counterpart. The pulse pattern synthesis is made with the help pre-calculated duty cycle expressions. In this way the carrier signals have not to be really synthesized, hence the hardware and the whole inverter control system becomes cheaper, more reliable and affo…
Measurement of Simplified Single- And Three-Phase Parameters for Harmonic Emission Assessment Based on IEEE 1459-2010
2021
This article investigates the feasibility of using a simplified approach, based on the measurement of power ratio parameters, for harmonic emissions assessment at the point of common coupling (PCC). The proposed approach comes from the common concept of power factor correction and the definitions of the IEEE Std. 1459-2010, where line utilization and harmonic pollution levels are evaluated by means of ratios between the power quantities of the apparent power decomposition. In addition to the IEEE Std. 1459–2010 indicators, in this article, the behavior is studied of additional parameters that are conceptually similar to those defined by the IEEE Std. 1459-2010. The suitability of such param…
LV Measurement Device Placement for Load Flow Analysis in MV Smart Grids
2016
This paper deals with the issue of measurement device placement for load flow analysis in medium-voltage (MV) distribution networks. The study is carried out using an innovative measurement algorithm for load flow analysis developed by the authors. It is based on low-voltage (LV) load power measurements applied on a backward/forward algorithm for the load flow resolution. The final aim is to identify the most suitable number and placement of the LV measurement points in order to limit the uncertainty on the power flow estimation to a target value. The proposed approach is based on the uncertainty evaluation of the estimated power flows; a sensitivity analysis is performed in order to assess…
Design considerations for transformerless series resonant inverters for induction heating
2002
The aim of the paper is to present some preliminary ideas in order to overcome the output transformer in series resonant inverters for induction heating applications. By adding a third reactive element to the conventional two element resonant inverter, the output matching transformer can be eliminated, allowing accommodation of the resonant frequency and load with the only drawback being the need for an overdimensioning of the output capacitor bank, and benefiting from inherent short-circuit protection.
New Power Conditioning System for Battery-free Satellite Buses with Maximum Power Point Tracking
2007
The purpose of this paper is describe a new conception of Power Conditioning Unit (PCU) developed to fulfill the requirements of BepiColombo Electronic Propulsion module. This load bus has very tough specification especially regarding transient response during total load switch-off ("beam out") which has to be less than 2% of the bus voltage. The conception we propose, is the new Sequential Switching Shunt Maximum Power Regulator (S3MPR) consisting in a S3R, to keep the SA voltage at its Maximum Power Point (MPP) followed by a Boost regulator to produce a constant 100V to supply the Electronic Propulsion (EP). This concept may also be of interest for other future missions involving high pow…
Isolated two-stage passive PFC rectifier for the Radioisotope Stirling Generator
2013
This paper describes an isolated, passive power factor correction rectifier devised for low-voltage, large-inductance, single-phase alternator, like the one used in the Radioisotope Stirling Generator. The power converter splits into two independent stages, the front-end rectifier corrects the power factor by adding a series capacitor in the AC line. Further, the rectifier, thanks to the alternator inductance, behaves as a constant-current source that powers a current-fed, zero voltage and zero current switching push-pull stage. This approach takes advantage of all parasitic elements to increase power density while keeping simple and reliable. Full description and analysis is given as well …
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…
Dynamic performance enhancement of AC/DC PFC boost converters by means of MRAS observers
2015
Controlling a Power Factor Corrected (PFC) boost converter is not a trivial task, because the higher the dynamic performance, the higher is the input current distortion. On the other hand, recent applications of these converters require fast transients in response to disturbances, such as sudden variations of load power, reference voltage and input voltage. Better performance can be obtained adding a feedforward action to the traditional control scheme, using observers to estimate the input voltage and the output current. However, the actual improvement depends on the dynamic performance of the chosen observers. This paper aims at evaluating the applicability and the performance of differen…