Search results for "Power station"
showing 10 items of 87 documents
Generation of heat and power from biogas for stationary applications: boilers, gas engines and turbines, combined heat and power (CHP) plants and fue…
2013
Biogas is produced during the anaerobic degradation of organic material. The produced biogas can be used for heat, electricity or cogeneration of heat and electricity in a combined heat and power plant (CHP). This chapter first discusses the key issues related to combustion of biogas/biomethane in different stationary equipments. It then describes the utilisation of biogas for the generation of electric power and heat in different stationary applications such as boilers, gas engines (CHP), micro turbines and fuel cells.
Preliminary CAD implementation of EU-DEMO primary heat transfer systems for HCPB breeding blanket option
2019
Abstract This paper focuses on the 3D CAD implementation of the pipework and the main equipment of the Primary Heat Transfer System of EU-DEMO fusion power plant. In particular, the systems related to the Helium-Cooled Pebble Bed Breeding Blanket option are considered here. During the pulse operation, the breeding blanket modules will be the main thermal power source; Divertor and the Vacuum Vessel will contribute in the definition of the total reactor power. All the In-Vessel generated power is rejected to the Power Conversion System through a molten salt Intermediate Heat Transport System. The latter is equipped with an Energy Storage System to allow for continuous operation also during t…
Analysis of Protected Accidental Transients in the EFIT Reactor With the RELAP5 Thermal-Hydraulic Code
2008
The European Facility for Industrial Transmutation (EFIT) is aimed at demonstrating the feasibility of transmutation process through the Accelerator Driven System (ADS) route on an industrial scale. The conceptual design of this reactor of about 400 MW thermal power is under development in the frame of the European EUROTRANS Integrated Project of the EURATOM Sixth Framework Program (FP6). EFIT is a pool-type reactor cooled by forced circulation of lead in the primary system where the heat is removed by steam generators installed inside the reactor vessel. The reactor power is sustained by a spallation neutron source supplied by a proton beam impinging on a lead target at the core centre. A …
Reconfiguration strategies to reduce mismatch effects on PV array: An Arduino-based prototype
2014
Today, solar energy represents a widespread source of electricity among all the renewable energies. One of the major problems concerning the photovoltaic (PV) arrays is the partial shading, that is the non-uniform irradiance on its parts. The partial shading leads to several undesired effects, such as mismatch between modules and a reduction of the production of electric energy. In order to alleviate the partial shading effects, different methods can be employed. Among them, the reconfiguration of the electrical connections between modules represents an alternative solution. In this paper, an algorithm of reconfiguration for a small-scale PV plant is proposed and experimental results showin…
CHP (combined heat and power) retrofit for a large MED-TVC (multiple effect distillation along with thermal vapour compression) desalination plant: H…
2016
Abstract Integrated power plants in “dual purpose” configuration may represent a viable option for energy cost abatement of desalted water produced by MED-TVC (Multiple Effect Distillation along with Thermal Vapour Compression). In this paper an existing large MED-TVC plant with a 36,000 m 3 /day capacity is studied: a plant retrofit is designed, based on a steam power plant with condensation and steam extraction used to drive the steam ejector. As the plant operates in CHP (Combined Heat and Power) mode, the possibility to assess the integrated “CHP + MED-TVC” as high efficiency cogeneration according to Directive 2004/8/EC is discussed. Based on a model developed in Engineering Equation S…
Technological performances upgrading and rehabilitation of building heritage inside the historic centre of Palermo
2021
The recovery of building heritage through the containment of carbon emissions is one of the strategies pursued by the city of Palermo. This design approach becomes more paradigmatic when it’s referred to sensitive and historic buildings or urban areas, having an international interest or involved in participatory projects for the Mediterranean city, well beyond the attention that citizens attest to them. We would analyse the Volta electrical Power Station, inside the harbour area and near the Castello a mare, interested by the overall rehabilitation of Palermo waterfront. This building qualifies itself, through a retrofit hypothesis proposed by the authors of this essay, as a significant ex…
Designing a Sustainable University Recharge Area for Electric Vehicles: Technical and Economic Analysis
2017
This article addresses the technical and economic challenges regarding the design of a “green” recharge area for electric vehicles at the University of Palermo in order to reduce costs and pollution connected to the charging process. Based on the behaviour of the student population, the electrical load is identified and two possible solutions are evaluated to manage the peak load: an orientation of the panels increasing the power at defined time and the use of a storage system. The main strength and weakness points of two systems are investigated by taking into account the Levelized Cost of Energy (LCOE), which reaches 75.3 €/MWh for the orientation of panel and 103 €/MWh for the storage sy…
Manufacturing tolerances effects on PV array energy production
2014
This paper investigates the tolerance effects of commercial photovoltaic modules in terms of electrical energy reduction of photovoltaic plants. Several commercial modules, having the same rated power, present different power tolerance values. A wide tolerance is an indicator of possible defects or differences in the production process and is responsible of remarkable reductions in the electricity production of photovoltaic plants. In this paper, thanks to the development of a suitable simulation tool, several simulations have been carried out, considering different tolerance and shading conditions for the PV array. Simulation results quantify the peak power value of the different plant con…
The Ignoble Fuel
2012
Perhaps the first historic mention of a substance derived from coal goes back to the Bible, when Yahweh orders Noah to build the famous ark.
Decay Heat Removal and Transient Analysis in Accidental Conditions in the EFIT Reactor
2008
The development of a conceptual design of an industrial-scale transmutation facility (EFIT) of several 100 MW thermal power based on accelerator-driven system (ADS) is addressed in the frame of the European EUROTRANS Integral Project. In normal operation, the core power of EFIT reactor is removed through steam generators by four secondary loops fed by water. A safety-related decay heat removal (DHR) system provided with four independent inherently safe loops is installed in the primary vessel to remove the decay heat by natural convection circulation under accidental conditions which are caused by a loss-of-heat sink (LOHS). In order to confirm the adequacy of the adopted solution for decay…