Fiber-Optic Insulating Link In A Telecommunication System For An Electric Power Plant
1990
The paper presents a fiber-optic insulating link coupling electric power substation with a dispa-tching telecommunication center. The advantages of employing the FO link in the power plant telecommunication system include insulating properties, resistance to EMI and high transmission capacity. The technical and economical analyses are complemented with the example of an application of the link to the 110/15 kV station. The two-directional communication system provides transmission of voice, telemetry, telesignalization and remote control signals.
Fiber - Optic Loop Network With Active Nodes For An Electrical Power Plant
1990
This paper presents a fiber optic loop network for a measurement and control system of an electric power plant. The network consists of the central computer terminal, the set of specially distributed digital FO links and local station installed at the important power facilities. The well-known FO link advantages contribUte to high reliability and safety of work of the system. The operation of the loop network, treated as an autonomous one, is controlled by a microcomputer system. Transmission protocols and the cooperation with the local station are also described. The proposed loop network model is illustrated with an example of the laboratory - scale system.
A discussion on variants of stand-alone electric powerplant equipped with transverse flux generators
2015
The paper discussed several designed variants of TFG with different number of poles, speed and dimensional coefficients starting from two base module variants with a rated power of 8kW and 11 kW respectively. The proposed layout came from reluctance one and it is suitable to equipped stand-alone electric power plant being a proper solution for isolated farms. The influence of large number of poles on torque density values obtained at low rotational speed is discussed in paper.
Advancements in DEMO WCLL breeding blanket design and integration
2017
Summary The water-cooled lithium–lead breeding blanket is a candidate option for the European Demonstration Power Plant (DEMO) nuclear fusion reactor. This breeding blanket concept relies on the liquid lithium–lead as breeder–multiplier, pressurized water as coolant, and EUROFER as structural material. The current design is based on DEMO 2015 specifications and represents the follow-up of the design developed in 2015. The single-module-segment approach is employed. This is constituted by a basic geometry repeated along the poloidal direction. The power is removed by means of radial–toroidal (i.e., horizontal) water cooling tubes in the breeding zone. The lithium–lead flows in a radial–poloi…
Cascaded PD-PI controller for active power frequency control of two-area multi-units power system
2016
In interconnected multi-area power system; the real power generation within each area has to be managed through active power frequency control considering scheduled power exchange. In this work, two different controllers, namely cascaded PD-PI and conventional PID controller are considered for analyzing the dynamic response of the two area interconnected power system. Area-1 consists of two reheat type thermal generating power plant units and area-2 comprises of two non-reheat type thermal power plant units. The controller gains of PD-PI and PID controllers are efficiently tuned by ‘Teaching Learning based Optimization Technique’. In area-1, 1% step load disturbance is applied for analyzing…
A simple and accurate model of photovoltaic modules for power system design
2014
Review on photovoltaic based active generator
2015
An active generator has the capacity to support frequency control and instantaneous power balance. The grid operator adjusts the power dispatch of generators according to power demand fluctuations. Photovoltaic (PV) based active generators can be used as load following generators in the same manner as other power dispatch generators. This new type of distribution system, based on active generator(s), needs new innovative management and operation strategies for increasing the penetration of intermittent renewable energy systems. The considered PV based active generator has three units, i.e., PV array, battery storage and super capacitor. In this review paper, the management and operation app…
A measurement methodology for monitoring a CHCP pilot plant for an office building
2003
Abstract In Mediterranean areas, climate conditions determine quite equal demand both for thermal and cooling energy. The possibility to convert a cooling demand in thermal one through an absorption chiller allows to extend widely the number of running hours of a cogeneration plant. A trigeneration pilot plant for two office building is described, in which an integrated lay-out includes a NG prime mover with heat exchanger, an absorption chiller and a reversible heat pump. The pilot plant is completed and pre-running test were performed. Different fluid dynamics parameters will be monitored, in order to build the actual cumulative curve for thermal power. The measurement methodology is also…
Efficiency increase in thermal desalination plants by matching thermal and solar distillation: theoretical analysis
2005
Abstract The effluent streams from MSF and MED plants retain substantial thermal and mechanical energy which is usually wasted as the streams are rejected into the environment. Recent environmental studies pose the question of environmental sustainability of desalination due to the large amount of heat and brine dissipated into the sea. Moreover the use of renewable energy so far have been confined to experimental studies or to the use in remote areas and no studies have been carried out on the coupling of a solar still plant with an existing thermal desalination installation in order to take advantage of the heat streams generated by the thermal plants. The combination of a solar desalinat…
An economic study about the installation of PV plants reconfiguration systems in Italy
2014
This paper shows the economic convenience of the application of a reconfiguration system for photovoltaic plants, considering the incentives system in Italy and its recent modifications. The reconfiguration is an alternative to the Distributed Maximum Power Point Tracking, DMPPT, technique used to overcome the mismatch problem in Photovoltaic, PV, plants. The reconfiguration techniques employ a microprocessor-based system that modifies the layout of the PV plant by physically changing the connections among modules. After the explanation of the working principle of the PV reconfiguration system allowing the improvement of the efficiency of the same plant and the relevant installation, the ma…