Linear Waves in Electrical Transmission Lines
1996
Nowadays, linear transmission lines provide vital links in virtually all communications and computer systems, and the parallel-wire line is still widely used today in open-wire form, in coaxial cables and microstrips. The standard twoconductor transmission line is an important familiar system, that is able to support the propagation of transverse electromagnetic modes and is of great interest in many practical situations. We have all often studied this electrical circuit or variation of it in elementary electronics, physics, or mathematics courses (Ramo et al. 1965, Davidson 1978, Badlock and Bridgeman 1981). In fact, the study of linear transmission lines is an old problem: in their simple…
A Novel Technique for Deembeding the Unloaded Resonance Frequency from Measurements of Microwave Cavities
2006
[EN] A novel technique to extract the influence of coupling networks on the resonant frequency of cavities in one-port measurements is presented. The determination of the unloaded resonant frequency is performed directly from measurements without either the need to obtain the electromagnetic fields in the resonator or to deembed the delay of transmission lines from the measuring equipment to the resonator. The importance of the Foster's form on the modeling of the frequency detuning of the resonators is also discussed and a criterion for the choice of the appropriate Foster's form is suggested. The procedure is validated with simulations and experimental measurements of manufactured cavities
Some effects of a buried electricity transmission cable on bulk soil.
2007
A case study in NW Italy investigating an underground electric line (1 m depth triple cable at operative voltages 220-380 kV) measured electric fields in the surrounding soil virtually close to zero but magnetic fields (microTs) 20 times the background level. After 6 months, the influence radius around the cable on microbial activity (estimated by soil ATP), organic carbon, and total nitrogen follows exactly the inverse trend of the MF, shifting the biological activity with a lag distance of 5 m from the 220 kV cable.
Secondary substation power line communications for medium voltage smart grids
2012
In this paper a performance analysis is carried out, in order to evaluate the possibility to employ power line communication (PLC) between secondary substations of a medium voltage (MV) distribution networks in a smart grid. The study is focused on the analysis of PLC technologies and the evaluation of the influence quantities on the communication performance in the most common case of by-pass connection at MV bus-bars of secondary substations. Different quantities have been analyzed as modulation techniques, requested bandwidth and bitrate, coupling device and system attenuation versus frequency in order to find the best solution for a reliable communication system. A complete model of a r…
Experimental investigation on PLC signal crossing of power transformers
2014
In this work the use of PLC in MV-LV networks is investigated, by means of experimental tests in the case of a two-ways MV/LV communication between two secondary substations. The two substations are connected by a MV overhead power line. Moreover each substation has a by-pass connection at MV bus-bars and a MV/LV power transformer. A ST7580 transceiver is used to inject the communication signal. The transceiver is embedded in a new interface device developed by the authors. In the paper the communication issues are introduced and some experimental tests are presented and discussed. Such tests have been carried out in the presence of voltage net, i.e. 24 kV, with the aim to verify the possib…
Risk evaluation and creep in conventional conductors caused by high temperature operation
2008
The advent of electricity market deregulation, the increased operating and overload temperatures of transmission line conductors have caused concern among TSOs (Transmission System Operators) and DSOs (Distribution System Operators) about the effect of elevated temperatures on conventional bare conductors of existing line. Nowadays building new lines is very difficult cause of increased costs to obtain rights of way, public intervention, etc.... Cost and lead times required to place new lines into service are now increased and the business in electric market is reduced for the limited possibility of transmission. Therefore, utilities are attempting to gain as much capacity as possible modif…
A novel approach to current transformer characterization in the presence of harmonic distortion
2009
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…
On the roadmap to supergrid in Sicily: LiDAR technology and HTLS conductors for uprating the 150 kV lines
2014
Difficulties in building new power lines in Italy because of authorization problems, and the production of electricity from renewable sources growing more and more, induces Terna S.p.A. (Italian TSO) to take advantage of existing overhead transmission lines. In order to increase the transmission capacity, Terna has used a software in GIS (Geographic Information System) environment which allows for the management of the interferences according to all the legislative bonds by referring to the LIDAR (Laser Imaging Detection and Ranging) remote sensing technology. This paper, after a description of the GIS and the LiDAR technology, shows how the calculation of the current capacity of some High …
GIS systems and LIDAR technology for the operation of HV lines. Sicilian transmission network applications
2013
The difficulties to build new power lines within the national territory cause of authorization problems, and the evermore growing production of electricity from renewable sources, induces Terna S.p.A. (Italian TSO) to take advantage of existing overhead transmission lines. Therefore, in order to increase the transmission capacity, and to optimize the maintenance and management of power lines, for some years Terna has been using a software in GIS environment (Geographic Information System) that referring to the LIDAR (Laser Imaging Detection and Ranging) remote sensing technology, allows to manage the interferences according to all the requirements and legislative bonds and to fulfill the im…
A new model for a safety analysis in a system of earthing systems interconnected through bare‐buried conductors
2009
PurposeThe purpose of this paper is to present a mathematical model for studying the effects of the interconnection through bare‐buried conductors (BBC) of the secondary substations' earthing system of an urban area.Design/methodology/approachThe developed methodology is based on three main points: the solution of the transmission lines' equations for the formulation of a lumped parameters model of a BBC considering the conductive effect; the division of the distribution network into simpler sub‐systems; and the calculation of all the voltages and currents of the medium voltage (MV) network and of the earthing systems using a multiport approach.FindingsThe methodology has been applied to va…