Search results for "Precision"

showing 10 items of 448 documents

GEOV1: LAI, FAPAR essential climate variables and FCOVER global time series capitalizing over existing products. Part 2: Validation and intercomparis…

2013

International audience; This paper describes the scientific validation of the first version of global biophysical products (i.e., leaf area index, fraction of absorbed photosynthetically active radiation and fraction of vegetation cover), namely GEOV1, developed in the framework of the geoland-2/BioPar core mapping service at 1 km spatial resolution and 10-days temporal frequency. The strategy follows the recommendations of the CEOS/WGCV Land Product Validation for LAI global products validation. Several criteria of performance were evaluated, including continuity, spatial and temporal consistency, dynamic range of retrievals, statistical analysis per biome type, precision and accuracy. The…

Accuracy and precision010504 meteorology & atmospheric sciencescouvert végétalcomparaison de modèlesBiomecritère de performanceSoil ScienceMagnitude (mathematics)Context (language use)01 natural sciencesGEOV1;Vegetation variables;Validation;GMES;Land monitoring core servicevalidation scientifiquefraction of absorbed photosynthetically active radiation (fAPAR)GEOV1ValidationfcoverFraction (mathematics)Computers in Earth SciencesLeaf area indexvariable climatiqueMilieux et Changements globauxfraction de couvert0105 earth and related environmental sciencesRemote sensinggmescarte de référenceanalyse statistiquefaparLand monitoring core serviceGeology04 agricultural and veterinary sciencesresolution spatiale15. Life on landComputer scienceLAIindice de surface foliaireSeaWiFSbiome13. Climate actionPhotosynthetically active radiationInformatique (Sciences cognitives)surveillance de l'environnement[SDE]Environmental Sciences040103 agronomy & agriculture0401 agriculture forestry and fisheriesEnvironmental scienceVegetation variables
researchProduct

Determination of one compound in the presence of a single interference. Linear absorbances method

1992

The paper exposes the theoretical and experimental principles of an analytical procedure for the determination of one compound in the presence of another with an overlapping absorption spectrum, without the need to use any standard solutions of the latter. The proposed method was applied to the determination of binary mixtures of known composition in order to assess its accuracy and precision.

Accuracy and precisionAbsorption spectroscopyChemistryAnalytical chemistryBinary numberStandard solutionInterference (wave propagation)BiochemistryAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

A comparative study on sample preparation procedures for supplementary foods by ICP-OES: Green chemistry considerations

2015

An inductively coupled plasma optical emission (ICP-OES) method was developed for the simultaneous determination of major, minor and trace elements in food. Preliminary studies focused on selecting suitable operational conditions in order to provide the highest sensitivity and to maximize the number of analytes to be determined without spectral or matrix interference. Ruthenium and rhenium were evaluated as internal standards and samples were analyzed at different dilution levels. Furthermore, a comparative study was carried out by using three sample digestion methods, microwave-assisted digestion with HNO3/H2O2, dry ashing and dry ashing with Mg(NO3)2/MgO as an ashing aid. Adequate precisi…

Accuracy and precisionAnalyteChromatographyChemistryGeneral Chemical EngineeringGeneral EngineeringAnalytical chemistryAnalytical ChemistryDilutionCertified reference materialsAshingInductively coupled plasma atomic emission spectroscopySample preparationInductively coupled plasmaAnalytical Methods
researchProduct

Determination of Cd, Cu, Pb and Zn content of infant formulas by differential pulse anodic stripping voltammetry (DPASV).

1994

The differential pulse anodic stripping voltammetry (DPASV) method described is based on the one reported by Hasse et al., but adapted to normal laboratory conditions. The values obtained in the estimation of the analytical parameters (linearity, detection and quantification limits, precision and accuracy) show that in the conditions described the method is sensitive enough, reliable and useful for determining these elements in infant formulas. A comparison between DPASV and atomic absorption spectroscopy (AAS) methods in the conditions described here shows that the former is less sensitive but that they are similar in precision. The cadmium, copper, lead and zinc contents of different type…

Accuracy and precisionAnalytical chemistrychemistry.chemical_elementZincNitric Acidlaw.inventionlawSpectrophotometryElectrochemistrymedicineHumansPolarographyCadmiummedicine.diagnostic_testSpectrophotometry AtomicInfantCopperAnodic stripping voltammetrychemistryMetalsSpainIndicators and ReagentsInfant FoodAtomic absorption spectroscopyPolarographyFood Science
researchProduct

Sample size in the monitoring of benthic macrofauna in the profundal of lakes: evaluation of the precision of estimates

1996

We discuss here the influence of sample size (number of replicates) on the accuracy and precision of the results when sampling profundal benthos with an Ekman grab according to the Finnish standard, SFS 5076, which is equivalent to the Swedish and Norwegian standards. The aim was to find criteria for choosing a sample size which would avoid any powerful influence of chance on the results without entailing an unreasonable amount of work for monitoring purposes.

Accuracy and precisionBenthosEcologyBenthic zoneSample size determinationStatisticsEnvironmental scienceSampling (statistics)Profundal zoneDeep water
researchProduct

Experimental and robust modeling approach for lead(II) uptake by alginate gel beads: influence of the ionic strength and medium composition.

2014

Abstract Systematic kinetic and equilibrium studies on the lead ions removal ability by Ca-alginate gel beads have been performed by varying several internal parameters, namely, number of gel beads, nature and composition of the ionic medium and pH, which allowed us to model a wastewater in order to closely reproduce the composition of a real sample. Moreover, the effects brought about the different ionic species present in the reacting medium have been evaluated. Differential Pulse Anodic Stripping Voltammetry (DP-ASV), has been systematically used to perform kinetic and equilibrium measurements over continuous time in a wide range of concentration. Kinetic and equilibrium data have been q…

Accuracy and precisionChemistryAnalytical chemistryIonic bondingKinetic energySurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsIonBiomaterialsAnodic stripping voltammetryColloid and Surface ChemistryIonic strengthAlginate gel beads Robust statistics Metal adsorption Wastewater treatment Ionic strength Differential Pulse Anodic Stripping Voltammetry Adsorption isotherms Adsorption kinetics Lead Heavy metalmedicineComposition (visual arts)Settore CHIM/01 - Chimica AnaliticaSwellingmedicine.symptomJournal of colloid and interface science
researchProduct

Information content of data and variables and types of weighting in least-squares regression methods

1990

Abstract Algorithms are given for evaluating the relative amount of useful information related to a particular parameter which is carried by individual data points and intervals of the variables. The algorithms provide an efficient means of using the information contained in a set of data. Applications to the optimization of weighting in regression methods are described. Several informational and combined informational-statistical types of weighting are studied as a means of improving the accuracy and precision of the parameters obtained by non-linear regression.

Accuracy and precisionChemistryRegression analysisStatistical weightBiochemistryRegressionAnalytical ChemistryWeightingSet (abstract data type)Content (measure theory)StatisticsEnvironmental ChemistryNonlinear regressionSpectroscopyAnalytica Chimica Acta
researchProduct

Comparison of novel and conventional calibration techniques for the analysis of urine samples using plasma source mass spectrometry combined with a n…

2012

The accuracy and precision of the analytical data from the analysis of liquid samples with high matrix load often suffer from a compromised performance of the sample introduction system. This is especially significant in the case of miniaturized, pneumatic low flow nebulizers. Alternative low-flow sampling devices based on different operating principles are imperative to overcome this drawback. The superior performance of such an alternative liquid sample introduction system for ICP-MS, the drop-on-demand (DOD) aerosol generator based on thermal inkjet technology, was recently outlined by the same group for the analysis of aqueous standard solutions. Current improvements of the system now a…

Accuracy and precisionChemistrybusiness.industryPlasma source mass spectrometryDrop (liquid)NozzleAnalytical chemistryStandard solutionAnalytical ChemistryMatrix (chemical analysis)Aerosol generatorOn demandProcess engineeringbusinessSpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Fluorimetric determination of amphetamine in urine by flow injection with on-line liquid–liquid extraction

2001

Abstract Determination of amphetamine in urine was performed by batch and flow injection methodologies. The suitable experimental conditions for fluorimetric measurements were established. The liquid–liquid extraction was carried out at pH 13 using diethyl ether as extracting reagent. The measurement conditions were 260 nm and 277 nm for excitation and emission wavelengths, respectively. The method requires standard addition calibration and Youden blank correction. The influence of the main metabolites of amphetamine and metamphetamine were studied. The accuracy and precision of the proposed method was tested and the method is adapted to the flow injection procedure with on-line extraction.

Accuracy and precisionChromatographyInjection ProcedureExtraction (chemistry)Fluorescence spectrometryAnalytical chemistryAnalytical Chemistrychemistry.chemical_compoundchemistryLiquid–liquid extractionReagentStandard additionDiethyl etherSpectroscopyMicrochemical Journal
researchProduct

Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM…

2000

The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, hav…

Accuracy and precisionGeneral Chemical EngineeringAnalytical chemistrychemistry.chemical_elementGeneral ChemistryIsotope dilutionPolyethyleneMass spectrometryMatrix (chemical analysis)Chromiumchemistry.chemical_compoundThird phasechemistrySafety Risk Reliability and QualityInstrumentationInductively coupled plasma mass spectrometryAccreditation and Quality Assurance
researchProduct