Search results for "Probe"
showing 10 items of 534 documents
Photonic nanopatterns of gold nanostructures indicate the excitation of surface plasmon modes of a wavelength of 50-100 nm by scanning near-field opt…
2003
Scanning near-field optical microscopy images of metal nanostructures taken with the tetrahedral tip (T-tip) show a distribution of dark and bright spots at distances in the order of 25-50 nm. The images are interpreted as photonic nanopatterns defined as calculated scanning near-field optical microscopy images using a dipole serving as a light-emitting scanning near-field optical microscopy probe. Changing from a positive to a negative value of the dielectric function of a sample leads to the partition of one spot into several spots in the photonic nanopatterns, indicating the excitation of surface plasmons of a wavelength in the order of 50-100 nm in metal nanostructures.
Scanning probe microscopies applied to the study of the domain wall in a ferroelectric crystal.
2007
Summary Scanning near-field optical microscopy is capable of measuring the topography and optical signals at the same time. This fact makes this technique a valuable tool in the study of materials at nanometric scale and, in particular, of ferroelectric materials, as it permits the study of their domains structure without the need of chemical etching and, therefore, not damaging the surface (as will be demonstrated later). We have measured the scanning near-field optical microscopy transmission, as well as the topography, of an RbTiOPO4 single crystalline slab, which exhibits two different of macroscopic ferroelectric domains. A chemical selective etching has been performed to distinguish b…
Possible Ca 2+ -dependent mechanism of apical outer hair cell modulation within the cochlea of the guinea pig
1998
Calcium ions were precipitated with potassium antimonate after injection of the inorganic calcium channel blocker MnCl2 or the inorganic potassium channel blockers BaCl2 or CsCl into the perilymph of the scala vestibuli of the guinea pig. The spatial distribution of the formed histochemical reaction products within the organ of Corti was studied by energy-filtering transmission-electron microscopy. Compared with untreated control ears, the number of the formed precipitates drastically increased at the extracellular side of the lamina reticularis after application of the various inorganic channel blockers. The apical side of the outer hair cells and the intervening Deiter cells were covered …
Immunohistochemical localization of polysialic acid in tissue sections: differential binding to polynucleotides and DNA of a murine IgG and a human I…
1990
For immunolocalization of alpha(2-8)-linked polysialic acid, which forms part of the neural cell adhesion molecule (N-CAM), two monoclonal antibodies, MAb735 and IgMNOV, were employed. Both antibodies have previously been shown to bind the extremely low immunogenic capsular polysaccharide of group B meningococci, which also consists of alpha(2-8) polysialic acid, but not to other, even closely related forms of polysialic acid. Despite the identical polysaccharide specificity of these two MAb, we observed marked differences of the staining pattern in tissue sections. We showed that these differences in immunostaining were due to the crossreactivity of IgMNOV with polynucleotides and DNA. MA…
Experimental study of hydrogen plasma breakdown in a 2.45 GHz microwave discharge
2013
Temporal evolution of microwave-plasma coupling, vacuum ultraviolet (VUV) light emission and plasma electron temperature and density is reported for a 2.45GHz microwave hydrogen discharge pulsed at 50Hz. Directional couplers, a VUV spectrometer and a Langmuir probe are used for the diagnostics of the plasma breakdown. A 5‐10 µs transient peak of light emission exceeding the steady-state intensity by a factor of 3.3 is observed in coincidence with an abrupt drop in the microwave electric field. Observed light emission intensities combined with cross section data indicate that the electron temperature during the breakdown transient exceeds the steady-state value of 4‐6eV by a factor 3, which …
Selective and Sensitive Chromofluorogenic Detection of the Sulfite Anion in Water Using Hydrophobic Hybrid Organic-Inorganic Silica Nanoparticles
2013
[EN] In water and wine: Chromofluorogenic detection of the sulfite anion in pure water was accomplished by using a new hybrid organic-inorganic material that contained a probe entrapped in hydrophobic biomimetic cavities. This material was used for the detection of sulfite in red wine. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Monitoring pH and ORP in a SHARON reactor
2011
This paper analyses the valuable information provided by the on-line measurements of pH and oxidation reduction potential (ORP) in a continuous single high ammonia removal over nitrite (SHARON) reactor. A laboratory-scale SHARON reactor equipped with pH, ORP, electric conductivity and dissolved oxygen (DO) probes has been operated for more than one year. Nitrogen removal over nitrite has been achieved by adding methanol at the beginning of anoxic stages. Time evolution of pH and ORP along each cycle allows identifying the decrease in nitritation rate when ammonia is consumed during the aerobic phase and the end of the denitrification process during the anoxic phase. Therefore, monitoring pH…
Off–on BODIPY-based chemosensors for selective detection of Al3+ and Cr3+versus Fe3+ in aqueous media
2014
[EN] Two new off-on BODIPY-based chemosensors that are highly sensitive for trivalent cations in aqueous solutions are described. Compound 2 exhibits selective sensing of Al3+ and Cr3+ versus Fe3+ through two different channels (UV-vis and fluorescence).
Numerical simulations of photon scanning tunneling microscopy: role of a probe tip geometry in image formation
2005
Abstract Numerical simulations of two-dimensional probe–object system emulating a photon scanning tunnelling microscope are presented. R -matrix propagation algorithm incorporated into the differential method was used to achieve an extended capability to rigorously model a realistic system consisting of both a probe and a sample. Influence of the probe tip parameters on image formation in scanning near-field microscopy has been investigated. Coupling of the near-field to a single-mode probe and formation of a guided fundamental mode in a probe were investigated for various probe widths and lengths. The influence of the probe taper shape and apex size on near-field images was studied for sin…
Analysis of image formation with a photon scanning tunneling microscope
1996
International audience; The photon scanning tunneling microscope (PSTM) is based on the frustration of a total internal reflected beam by the end of an optical fiber. Until now it has been used to obtain topographic information, generally for smooth samples. We report theoretical as well as experimental results on the observation of a step on a quartz substrate with the PSTM. These results demonstrate the effects on image formation of the distance between the fiber tip and the sample surface, the orientation of the incident beam with respect to the step, the polarization, and the coherence of the light. Good agreement exists between numerical simulations and experiments. We show that a pert…