Search results for "Process Engineering"
showing 10 items of 931 documents
A Validation Methodology for a Combined Heating Cooling and Power (CHCP) Pilot Plant
2004
A great number of variables significantly influence the energetic, environmental and economic results of CHP (Combined Heating and Power) and CHCP (Combined Heating Cooling and Power) plants operation, and as a consequence their project activity is rather complex. In order to select the best layout and properly size the machines, detailed data on hourly electric, thermal, and cooling demand are necessary, so that a series of plant life cycle simulations may have to be carried out. Unfortunately, such detailed data are rarely available, because energy consumptions data for existing buildings are usually derived from aggregated monthly or bimonthly gas and electricity bills. Even more difficu…
Life Cycle Assessment Performance Comparison of Small Solar Thermal Cooling Systems with Conventional Plants Assisted with Photovoltaics
2012
Abstract Life Cycle Assessment (LCA) allows for the consideration of energy consumption and environmental impacts associated with all the stages of a product's life, from the cradle to the grave . Starting from the results obtained in the IEA SHC Task 38 framework for the LCA of small solar assisted heat driven chillers, the application of such methodology has been extended to systems with a conventional compression chiller assisted by a photovoltaic plant. This study aims to provide a more comprehensive investigation through a comparison of these two families of solar assisted cooling systems (with solar thermal or PV), which is an important topic for studies concerning the research of eff…
A methodology for sizing a trigeneration plant in mediterranean areas
2003
Combined heat and power production is an old and well-known technique for the rational use of energy and, thanks to more than fifty years of experience, the state of art can be considered very advanced from a technological point of view. Trigeneration, that is combined electric, heat and cooling energy production, is however a quite recent technology and is becoming economically viable thanks to the commercial spread of absorption chillers. In fact, a well-projected trigeneration plant can achieve better results than a cogenerative one. The CHCP plant benefits over CHP will be underlined, showing the effects of regularisation of annual thermal load curves generated by consumption for feedin…
Characterization of cooling loads in the wine industry and novel seasonal indicator for reliable assessment of energy saving through retrofit of chil…
2020
Abstract The food sector is a major consumer of energy and growing efforts are being made in the search for solutions that will guarantee the efficient and sustainable use of energy resources. Among the different sectors, wineries are attracting particular interest due to the continuous growth of the global market and production. Surveys conducted in the winemaking sector have highlighted the importance of performing accurate energy audits and have identified the installation of efficient refrigeration systems as a promising solution in a variety of cases. Unfortunately, the savings achievable by efficient cooling technologies are often estimated using simplified approaches which do not tak…
Exergoeconomic analysis as support in decision-making for the design and operation of multiple chiller systems in air conditioning applications
2020
Abstract Multiple-chillers systems represent viable solutions for medium/large-scale air conditioning applications characterized by variable cooling demand. The energy efficiency of such systems is influenced by the number of chillers, the combination of cooling capacities, and the load-sharing among the units. Large efforts have been devoted to developing efficient operation strategies for these systems, but rules of thumb are usually adopted for selecting cooling capacities thus leaving room for energy and economic savings. In this paper, exergoeconomic analysis is proposed as a promising method to identify near-optimal design and operation strategies, due to the capability of exergoecono…
Energy balance and life cycle assessment of small size residential solar heating and cooling systems equipped with adsorption chillers
2017
Abstract Solar heating and cooling systems for space heating and cooling are experiencing a growing trend and interest. However, the actual energy and environmental performance of small/medium size installations is not clearly foreseeable. In this paper, an analysis of such systems using adsorption chillers in different European climates is presented. Solar systems have been simulated in TRNSYS and compared to a conventional system employing a vapour compression unit. The results have been used for a Life Cycle Assessment (LCA) study, determining the potential impact during the whole life of the system, from raw materials supply to its end-of-life. The LCA has been carried out by using the …
Dependence of solvent quality on the composition of copolymers: experiment and theory for solutions of P(MMA-ran-t-BMA) in toluene and in chloroform.
2014
The interaction of toluene with P(MMA-ran-t-BMA) and with the corresponding homopolymers was determined via vapor pressure measurements at 30, 50 and 70 °C. A unified thermodynamic approach served for the modeling of the results. It is capable of describing the behavior of the different solutions by means of two adjustable parameters, one representing the effective number of solvent segments and the other accounting for the interactions between the components. The solvent quality of toluene passes a maximum, a minimum and another maximum upon an increase of the t-BMA content of the copolymer at all temperatures. A similar behavior is discernable from vapor pressure data of chloroform publis…
Ultrasound-assisted green solvent extraction of high-added value compounds from microalgae Nannochloropsis spp.
2015
Abstract The aim of this work was to investigate ultrasound (US)-assisted green solvent extraction of valuable compounds from the microalgae Nannochloropsis spp. Individual green solvents (water, ethanol (EtOH), dimethyl sulfoxide (DMSO)) and binary mixture of solvents (water-DMSO and water-EtOH) were used for the extraction procedures. Maximum total phenolic compounds yield ( Y p ≈ 0.33) was obtained after US pre-treatment ( W = 400 W, 15 min), being almost 5-folds higher compared to that found for the untreated samples and aqueous extraction ( Y p ≈ 0.06). The highest yield of total chlorophylls ( Y c ≈ 0.043) was obtained after US ( W = 400 W, 7.5 min), being more than 9-folds highe…
Analysis of eicosapentaenoic and docosahexaenoic acid geometrical isomers formed during fish oil deodorization.
2006
International audience; Addition of long-chain polyunsaturated fatty acids (LC-PUFAs) from marine oil into food products implies preliminary refining procedures of the oil which thermal process affects the integrity of LC-PUFAs. Deodorization, the major step involving high temperatures, is a common process used for the refining of edible fats and oils. The present study evaluates the effect of deodorization temperature on the formation of LC-PUFA geometrical isomers. Chemically isomerized eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) were used as reference samples. Fish oil samples have been deodorized at 180, 220 and 250 °C for 3 h and pure EPA and DHA fatty acid methyl esters…
Synchronized gradient elution in capillary liquid chromatography
2013
Abstract The synchronization of injection valve operation and gradient elution in capillary liquid chromatography (cHPLC) is studied. Focus is placed on the cHPLC systems which rely on the splitting of a primary flow to provide the much smaller secondary flow required at the injection device and analytical column. Owing to the tiny secondary flow rates, synchronization is necessary to achieve proper optimization of gradient elution methods. Otherwise, there is a risk of having the analytes totally or partially eluted in the initial isocratic conditions, and there is no control on the actual gradient profile reaching the column. Synchronization is first achieved by switching back the valve t…