Search results for "Process"

showing 10 items of 22310 documents

Central and Peripheral Contributions to Fatigue after Electrostimulation Training

2006

Purpose: We examined the effect of 4 (WK4) and 8 wk (WK8) of neuromuscular electrical stimulation (NMES) training on both endurance time and mechanisms contributing to task failure. Methods: Ten males performed a fatiguing isometric contraction with the knee extensor muscles at 20% of maximal voluntary contraction (MVC) until exhaustion before (B), at WK4, and at WK8 of NMES training. The electromyographic (EMG) activity and muscle activation obtained under MVC were recorded before and after the fatiguing task to assess central fatigue. Torque and EMG responses obtained under electrically evoked contractions were examined before and after the fatiguing task to analyze peripheral fatigue. Re…

AdultMalemedicine.medical_specialtyTime FactorsContraction (grammar)Neuromuscular JunctionPhysical Therapy Sports Therapy and RehabilitationIsometric exerciseElectromyographyFeedbackVoluntary contractionPhysical medicine and rehabilitationIsometric ContractionmedicineHumansOrthopedics and Sports MedicineMuscle Skeletalmedicine.diagnostic_testKnee extensorsElectromyographybusiness.industryReproducibility of ResultsSignal Processing Computer-AssistedMuscle activationmusculoskeletal systemElectric StimulationRate of increasePeripheralTorquePhysical FitnessMuscle FatiguePhysical EndurancebusinessFemoral NerveMuscle ContractionMedicine & Science in Sports & Exercise
researchProduct

Neuromuscular fatigue differs with biofeedback type when performing a submaximal contraction

2007

The aim of the study was to examine alterations in contractile and neural processes in response to an isometric fatiguing contraction performed with EMG feedback (constant-EMG task) when exerting 40% of maximal voluntary contraction (MVC) torque with the knee extensor muscles. A task with a torque feedback (constant-torque task) set at a similar intensity served as a reference task. Thirteen men (26+/-5 yr) attended two experimental sessions that were randomized across days. Endurance time was greater for the constant-EMG task compared with the constant-torque task (230+/-156 s vs. 101+/-32s, P0.01). Average EMG activity for the knee extensor muscles increased from 33.5+/-4.5% to 54.7+/-21.…

AdultMalemedicine.medical_specialtyTime FactorsContraction (grammar)medicine.medical_treatmentBiophysicsNeuroscience (miscellaneous)Isometric exerciseBiofeedbackbehavioral disciplines and activitiesFeedbackSubmaximal contractionPhysical medicine and rehabilitationIsometric ContractionmedicineHumansKneeEmg biofeedbackRehabilitationKnee extensorsElectromyographybusiness.industrymusculoskeletal systemTorqueNeuromuscular fatigueMuscle FatiguePhysical EnduranceNeurology (clinical)businesspsychological phenomena and processesJournal of Electromyography and Kinesiology
researchProduct

Individual music therapy for depression: randomised controlled trial

2011

BackgroundMusic therapy has previously been found to be effective in the treatment of depression but the studies have been methodologically insufficient and lacking in clarity about the clinical model employed.AimsTo determine the efficacy of music therapy added to standard care compared with standard care only in the treatment of depression among working-age people.MethodParticipants (n= 79) with an ICD–10 diagnosis of depression were randomised to receive individual music therapy plus standard care (20 bi-weekly sessions) or standard care only, and followed up at baseline, at 3 months (after intervention) and at 6 months. Clinical measures included depression, anxiety, general functioning…

AdultMalemedicine.medical_specialtyTime FactorsMusic therapyAdolescentAnxietySeverity of Illness Indexlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineQuality of life (healthcare)Randomized controlled triallawSeverity of illnessmedicineHumansAffective Symptoms030212 general & internal medicinePsychiatryMusic TherapyFinlandDepression (differential diagnoses)ta515Psychiatric Status Rating ScalesDepressive DisorderIntention-to-treat analysisOdds ratioMiddle Agedta3124Intention to Treat Analysis030227 psychiatryPsychiatry and Mental healthOutcome and Process Assessment Health Careta6131Quality of LifePhysical therapyPsychotherapy BriefAnxietyFemalemedicine.symptomPsychologyProgram EvaluationThe British Journal of Psychiatry
researchProduct

Centrifugal (inside-out) enhancement of liver hemangiomas: a possible atypical appearance on contrast-enhanced US.

2007

Abstract Objective To report the prevalence and to describe the atypical centrifugal (inside-out) appearance of contrast-enhancement of liver hemangiomas on contrast-enhanced sonography. Materials and methods Baseline and SonoVue ® -enhanced ultrasonography of 92 patients with 158 liver hemangiomas – considered atypical at grey-scale examination and confirmed by computed tomography, magnetic resonance imaging and ultrasound follow-up – were reviewed in consensus by two experienced radiologists, who evaluated baseline echogenicity and the dynamic enhancement pattern of each lesion looking for the presence of central enhancing foci in the arterial phase followed by a centrifugal (inside-out) …

AdultMalemedicine.medical_specialtyTime FactorsSecond-harmonic imaging microscopySulfur HexafluorideContrast MediaAngiomaHepatic ArterymedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingUltrasonography Doppler ColorPhospholipidsAgedMicrobubblesmedicine.diagnostic_testbusiness.industryVascular diseasePortal VeinUltrasoundLiver NeoplasmsEchogenicityMagnetic resonance imagingUltrasonography DopplerGeneral MedicineMiddle Agedmedicine.diseaseImage EnhancementMagnetic Resonance ImagingUltrasonography Doppler PulsedLiver HemangiomaFemaleRadiologyTomographybusinessHemangiomaTomography X-Ray ComputedFollow-Up StudiesEuropean journal of radiology
researchProduct

Lateralized effect of rapid-rate transcranial magnetic stimulation of the prefrontal cortex on mood.

1996

We studied the effects of rapid-rate transcranial magnetic stimulation (rTMS) of different scalp positions on mood Ten normal volunteers rated themselves before and after rTMS on five analog scales labeled ``Tristeza99 (Sadness), ``Ansiedad99 (Anxiety), ``Alegria99 (Happiness), ``Cansancio99 (Tiredness), and ``Dolor/Malestar99 (Pain/Discomfort). rTMS was applied to the right lateral prefrontal, left prefrontal, or midline frontal cortex in trains of 5 seconds9 duration at 10 Hz and 110% of the subject9s motor threshold intensity. Each stimulation position received 10 trains separated by a 25-second pause. No clinically apparent mood changes were evoked by rTMS to any of the scalp positions …

AdultMalemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentmedia_common.quotation_subjectEmotionsHappinessPainPrefrontal CortexStimulationAudiologyAnxietybehavioral disciplines and activitiesFunctional LateralityReference ValuesCortex (anatomy)mental disordersmedicineHumansPrefrontal cortexmedia_commonTranscranial Magnetic StimulationFrontal LobeTranscranial magnetic stimulationSadnessAffectMoodmedicine.anatomical_structureOrgan SpecificityScalpLateralityFemaleNeurology (clinical)PsychologyNeurosciencepsychological phenomena and processesNeurology
researchProduct

A Single-Center Experience with Lung Transplants During the COVID-19 Pandemic

2021

BACKGROUND This single-center study analyzed distinctions between lung transplants performed in the Department of Cardiac and Vascular surgery of the University Clinical Center in Gdansk, Poland before and during the COVID-19 pandemic. MATERIAL AND METHODS There were 189 patients who underwent the qualification procedure to lung transplantation in the Department of Cardiac and Vascular Surgery of the University Clinical Center in Gdansk, Poland in the years 2019 and 2020. The control group consisted of 12 patients transplanted in 2019, and the study group consisted of 16 patients transplanted in 2020. RESULTS During 2019, the qualification process was performed in 102 patients with pulmonar…

AdultMalemedicine.medical_specialtyTissue and Organ ProcurementCoronavirus disease 2019 (COVID-19)Waiting Listsmedicine.medical_treatmentSingle CenterHealth Services AccessibilityPandemicmedicineLung transplantationHumansPandemicsAgedTransplantationLung transplantsOriginal PaperGeographic areabusiness.industryMortality rateGeneral surgeryCOVID-19General MedicineVascular surgeryMiddle AgedOutcome and Process Assessment Health CareFemalePolandbusinessFollow-Up StudiesLung TransplantationAnnals of Transplantation
researchProduct

Microcirculation in the healing of surgical wounds in the oral cavity.

2013

Abstract. The aim of this research is to evaluate in vivo the characteristics of microcirculation after taking a biopsy sample from the oral mucosa. 20 patients were recruited to the study and all underwent an oral mucosa biopsy for the excision of benign neoformations. The modifications in the oral microcirculation were evaluated in vivo in correspondence to the surgical site through videocapillaroscopy at three different times: 30 min before the biopsy; 48 h after the biopsy; and 7 days after the biopsy. The statistical significance was checked with the Mann–Whitney U-test (P < 0.05). The analysis of videocapillaroscopic patterns showed statistically significant variations relative to the…

AdultMalemedicine.medical_specialtyVideo RecordingMicroscopic AngioscopyFibromaMicrocirculationMicroscopic AngioscopyYoung AdultDouble-Blind MethodIn vivoBiopsymedicineImage Processing Computer-AssistedHumansOral mucosaAgedMouth neoplasmMouthWound Healingoral microcirculationmedicine.diagnostic_testPapillomabusiness.industrySettore BIO/16 - Anatomia UmanaMicrocirculationBiopsy NeedleOptical ImagingSurgical woundvideocapillaroscopysurgical wounds.Middle AgedSurgeryCapillariesTongue Neoplasmsmedicine.anatomical_structureOtorhinolaryngologyLip NeoplasmsSurgeryFemaleMouth NeoplasmsOral SurgerybusinessWound healingFollow-Up StudiesInternational journal of oral and maxillofacial surgery
researchProduct

Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposes

2013

Accepted version of an article in the journal: Medical Engineering and Physics. Also available from the publisher at: http://dx.doi.org/10.1016/j.medengphy.2013.03.002 In a clinical study, a novel wireless electrocardiogram (ECG) recorder has been evaluated with regard to its ability to perform arrhythmia diagnostics. As the ECG recorder will detect a "non-standard" ECG signal, it has been necessary to compare those signals to "standard" ECG recording signals in order to evaluate the arrhythmia detection ability of the new system. Simultaneous recording of ECG signals from both the new wireless ECG recorder and a conventional Holter recorder was compared by two independent cardiology specia…

AdultMalemedicine.medical_specialtyambulatory electrocardiographyBiomedical EngineeringBiophysicsElectrocardiographyYoung Adultevaluation studiesmedicineHumansWirelessMedical physicscardiovascular diseasesChildReference standardsAgedAmbulatory electrocardiographySensor systemclinical trialsbusiness.industryReproducibility of ResultsArrhythmias CardiacSignal Processing Computer-AssistedVDP::Technology: 500::Information and communication technology: 550Middle AgedReference StandardsHolter monitoringClinical trialVDP::Medical disciplines: 700wireless ECG sensorFemalebusinessTelecommunicationsWireless TechnologyClinical evaluationHolter monitoring
researchProduct

Two-dimensional echocardiographic evaluation of left ventricular ejection fraction by the ellipsoid single-plane algorithm: a reliable method for ass…

1995

The reliability of two-dimensional (2D) echocardiographic estimation of left ventricular ejection fraction (EF) is commonly recognized, but no satisfactory data are available about the accuracy of low or very low EF values determined by 2D echocardiography (ECHO-EF). The purpose of our study was to assess the reliability of low ECHO-EF values obtained using a simple time-economical algorithm such as the ellipsoid single-plane area-length method. Radionuclide angiography (RAD-EF) was taken as the standard of comparison. We studied 59 consecutive patients (31 women and 28 men) referred to our echocardiographic laboratory. Both 2D echocardiography and radionuclide angiography were blindly perf…

AdultMalemedicine.medical_specialtyanimal structuresSettore MED/09 - Medicina InternaCardiac Output LowVentricular Function LeftVentricular Dysfunction LeftRadionuclide angiographyVentricule gaucheReference ValuesInternal medicinemedicineHumansPharmacology (medical)AgedEjection fractionmedicine.diagnostic_testPlane (geometry)business.industryTwo dimensional echocardiographyReproducibility of ResultsGated Blood-Pool ImagingSignal Processing Computer-AssistedStroke VolumeMiddle AgedEllipsoidSettore MED/11 - Malattie Dell'Apparato CardiovascolareArea length methodTwo dimensional echocardiography Area-lenght method Radionuclide angiography Ejection fraction Regression analysisEchocardiographyCardiologyFemaleCardiology and Cardiovascular MedicinebusinessNuclear medicineAlgorithms
researchProduct

Relation between late potentials and echocardiographically determined left ventricular mass in healthy subjects.

1991

AdultMalemedicine.medical_specialtybusiness.industryHeart VentriclesHealthy subjectsCardiomegalySignal Processing Computer-AssistedVentricular Function LeftLeft ventricular massElectrocardiographyEchocardiographyInternal medicineCardiologymedicineHumansFemaleCardiology and Cardiovascular MedicinebusinessThe American journal of cardiology
researchProduct