Three-dimensional Cross-Platform Planning for Complex Spinal Procedures
2017
STUDY DESIGN A feasibility study. OBJECTIVE To develop a method based on the DICOM standard which transfers complex 3-dimensional (3D) trajectories and objects from external planning software to any navigation system for planning and intraoperative guidance of complex spinal procedures. SUMMARY OF BACKGROUND DATA There have been many reports about navigation systems with embedded planning solutions but only few on how to transfer planning data generated in external software. MATERIALS AND METHODS Patients computerized tomography and/or magnetic resonance volume data sets of the affected spinal segments were imported to Amira software, reconstructed to 3D images and fused with magnetic reson…
Isolation of fibroblasts for coating of meshes for reconstructive surgery: differences between mesh types.
2009
Aims: An extensive colonization of surgical meshes with autologous fibroblasts may reduce complications. Therefore, we aimed to establish a technique that allows isolation and propagation of fibroblasts from vaginal biopsies. Using these cells we tested the applicability of several clinically applied meshes for fibroblast coating. Materials & methods: Fibroblasts were isolated from vaginal tissue after digestion with collagenase. Characterization was performed by immunostaining for cytokeratin 5, 6 and 14, smooth muscle actin and vimentin. A semiquantitative technique was applied to determine the degree of mesh coating 5 h and 5 weeks after seeding of fibroblasts. Seven meshes of diffe…
Sociodemographic Determinants for the Health-Related Quality of Life of Patients with Vascular Amputations as Determined with the Prosthesis Evaluati…
2020
Background: To identify the sociodemographic variables independently related to the different dimensions of the Prosthesis Evaluation Questionnaire (PEQ). Methods: An observational, cross-sectional study was conducted, with a sample of 61 Spanish vascular amputees (Valencia, Spain). Included in this study are the results of the PEQ and explanatory-sociodemographic variables, as well as a descriptive and analytic analysis. Results: Gender differences were observed in &ldquo
Tissue response and biomaterial integration: the efficacy of in vitro methods
2002
Implantation involves tissue trauma, which evokes an inflammatory response, coupled to a wound healing reaction, involving angiogenesis, fibroblast activation and matrix remodelling. Until now the type and extent of such reactions to give optimal integration of various biomaterials are practically unknown. Three principal fields of research can yield useful data to understand these phenomena better: studies on explanted biomaterials, animal models and relevant in vitro techniques. This paper will present examples of the latter field and the application of endothelial cell (EC) culture systems to study the effects of important tissue (e.g. pro-inflammatory cytokines, chemokines) and material…
Observational study: The use of the ventralight Echo PS (positioning system) prosthesis in the treatment of incisional hernia
2020
The treatment of incisional hernias, especially those that are multiple or recurring, has always represented important challenges for surgeons. An incisional hernia is a mechanical damage of the abdominal wall that can result in respiratory problems and alterations of splanchnic circulation, especially when in large size hernias. The increasing availability of prostheses with greater resistance Romato infections and tension, lightness, biocompatibility, and reduced visceral adhesions has improved outcomes and minimized relapses. It is still important, however, to carefully choose the type of prosthesis and surgical technique, whether laparotomic or laparoscopic, correlated to the positionin…
Closed foldable capsular rings
2004
A new foldable capsular tension and bending ring system with a sharp-edged design is described. The closed foldable capsular rings (CFCR) consist of 8 hydrophobic and 8 hydrophilic ring segments. The CFCRs have a 9.2 mm minimum overall diameter. The CFCRs were inserted using various cartridge systems or a two-folded technique with a forceps. The CFCRs were implanted after phacoemulsification through a small (1.6 to 3.2 mm) incision in 104 human adult eyes without intraoperative complications. No postoperative complications such as capsule folds or inward bending were observed over a 6-month follow-up. Posterior capsule opacification was minimal or absent in all eyes.
The titanium-made growth-guidance technique for early-onset scoliosis at minimum 2-year follow-up: A prospective multicenter study.
2019
Background The management of early-onset scoliosis (EOS) remains a serious challenge in pediatric orthopedics. The growth-guidance system (GGS) is a surgical option that allows continuous growth along a rod, averting the need for repeated operative lengthening. Objectives The objective of this study was to evaluate the outcomes of the GGS in the treatment of EOS. Material and methods A prospective study, including 81 patients from 4 departments treated with this method from 2013 to 2015, was conducted with a minimum follow-up period of 24 months. The follow-up data of 57 patients was available, thus the drop-out rate was 29.63%. There were 44 girls with a mean age of 10.03 years and 13 boys…
Fixation-free incisional hernia repair in the elderly: our experience with a tentacle-shaped implant.
2016
Background: Incisional hernia in aged patients represents a challenge even for experienced surgeons. Besides increased risk of complications due to comorbidities, mesh fixation and assuring a sufficient mesh overlap of the defect are the main issues in carrying out the repair. Aims: In order to assure broader coverage of the abdominal wall and a tension- and fixation-free repair, a specifically designed prosthesis was developed for the surgical treatment of incisional hernias. The results of a fixation-free incisional hernia repair carried out in elderly patients using a tentacle-shaped implant are reported herewith. Methods: A tentacle-shaped flat mesh with a large central body and integra…
Improving cytocompatibility of Co28Cr6Mo by TiO 2 coating: gene expression study in human endothelial cells
2013
Cobalt-based materials are widely used for coronary stents, as well as bone and joint implants. However, their use is associated with high corrosion incidence. Titanium alloys, by contrast, are more biocompatible owing to the formation of a relatively inactive titanium oxide (TiO 2 ) layer on their surface. This study was aimed at improving Co28Cr6Mo alloy cytocompatibility via sol–gel TiO 2 coating to reduce metal corrosion and metal ion release. Owing to their role in inflammation and tissue remodelling around an implant, endothelial cells present a suitable in vitro model for testing the biological response to metallic materials. Primary human endothelial cells seeded on Co28Cr6Mo showe…
Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management
2019
Purpose: To evaluate the visual quality results when fitting a corneo-scleral contact lens (CScL) after intracorneal ring segment (ICRS) implantation for keratoconus management. Methods: Twenty-seven eyes of 27 patients with keratoconus underwent ICRS implantation and had CScL fitted as their visual quality was unsatisfactory with their spectacles or contact lenses. Patients received a complete eye examination, refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count, and visual quality assessment using contrast sensitivity and aberrometry tests. A diagnostic trial set was used in the fitting process…