Search results for "Prostheses and Implant"
showing 10 items of 75 documents
Silicone-Silver Penile Prosthesis: Description, Operative Approach and Results
1980
A silicone penile prosthesis in which silver wires are embedded to allow for voluntary bending of the penis for urination and resting position and for straightening for intercourse is described. The implantation is done via a hemicircular incision on the dorsum of the penis in the sulcus coronarius. Buck's fascia is identified and opened, and the corpora are dilated up to 30F. After the exact length is determined with a special sizer the prosthesis is slipped into each corpus cavernosum. The advantage of this approach is the optimal insertion of the prosthesis distal to the sulcus coronarius, thereby preventing kinking of the glans during intercourse. Our experiences with the implantation i…
E-PTFE (Gore-Tex) implant with or without low-dosage mitomycin-C as an adjuvant in penetrating glaucoma surgery: 2 year randomized clinical trial.
2008
Purpose: To test the expanded polytetrafluoroethylene (ePTFE) as a new adjuvant in trabeculectomy. Methods: Consecutive glaucoma surgical inpatients were observed at the Department of Ophthalmology of Palermo University. Sixty patients (60 eyes) were randomly assigned to undergo trabeculectomy (T), trabeculectomy with mitomycin-C (TMMC), with ePTFE (TG) or with mitomycin-C and ePTFE (TGMMC). Postoperative visits were scheduled at 24 hr, 7 days, 1, 3, 6, 12, 18 and 24 months. Complete success and qualified success were assessed at two target intraocular pressure (IOP) levels – £21 and £17 mmHg – by Kaplan–Meier curves. Results: The postoperative IOP reduction was significant (P < 0.01) at th…
Biodegradable collagen matrix implant vs mitomycin-C as an adjuvant in trabeculectomy: a 24-month, randomized clinical trial
2011
AIM: To verify the safety and efficacy of Ologen (OLO) implant as adjuvant compared with low-dosage mitomycin-C (MMC) in trabeculectomy. METHODS: This was a prospective randomized clinical trial with a 24-month follow-up. Forty glaucoma patients (40 eyes) were assigned to trabeculectomy with MMC or OLO. Primary outcome includes target IOP at ≤21, ≤17, and ≤15 mm Hg; complete (target IOP without medications), and qualified success (target IOP regardless of medications). Secondary outcomes include bleb evaluation, according to Moorfields Bleb Grading System (MBGS); spectral domain optical coherence tomography (SD-OCT) examination; number of glaucoma medications; and frequency of postoperative…
Comparison of 2 Zero-Profile Implants in the Treatment of Single-Level Cervical Spondylotic Myelopathy: A Preliminary Clinical Study of Cervical Disc…
2016
Objectives Cervical disc arthroplasty (CDA) with Discover prosthesis or anterior cervical discectomy and fusion (ACDF) with Zero-P cage has been widely used in the treatment of cervical spondylotic myelopathy (CSM). However, little is known about the comparison of the 2 zero-profile implants in the treatment of single-level CSM. The aim was to compare the clinical outcomes and radiographic parameters of CDA with Discover prosthesis and ACDF with Zero-P cage for the treatment of single-level CSM. Methods A total of 128 consecutive patients who underwent 1-level CDA with Discover prosthesis or ACDF with Zero-P cage for single-level CSM between September 2009 and December 2012 were included in…
New aspects in the histological examination of polyethylene wear particles in failed total joint replacements.
2002
The most important long-term complication in total joint replacements is aseptic osteolysis. Wear particles such as polyethylene (PE) debris are considered to be one of the causes that play a central role. Several studies indicated that PE can be visualised in paraffin-embedded tissue sections not only by polarised light, but also after oil red staining. To determine whether oil red staining enables sensitive detection of PE, we examined staining of mechanically-produced PE particles by oil red. Furthermore, we studied oil red staining of paraffin-embedded tissue specimens of patients with failed uncemented and cemented total knee and hip prostheses. We applied double labelling of sections …
Blood metal levels after minimally invasive repair of pectus excavatum
2021
Abstract OBJECTIVES Minimally invasive repair of pectus excavatum (MIRPE) is the most popular surgical approach for paediatric patients with pectus excavatum. A substernal stainless still bar is inserted and left in place for 3 years and then removed. Our goal was to investigate blood metal levels after MIRPE and to correlate them with surgical details, such as the numbers of bars and stabilizers and the length of time the bar was in place. METHODS Blood levels of iron, chromium, manganese, molybdenum and nickel were analysed in 130 teenagers (108 boys and 22 girls) who had MIRPE using inductively coupled plasma mass spectrometry. A total of 62 patients were operated on using MIRPE (study…
A New Prosthetic Implant for Inguinal Hernia Repair: Its Features in a Porcine Experimental Model
2011
Even after more than 100 years of inguinal hernia repair, the rate of complications and recurrence remains unacceptably high. In the last decades, few effective advances in surgical technique and materials have been made. The authors see them as minor adjustments in the shape and materials of the prosthetic implants. Still, the underlying genesis of inguinal hernia remains undefined. Based upon this, it seems the surgical repair of inguinal protrusions cannot be based upon the pathogenesis because the etiology to date has not been addressed. Most hernia repairs are performed with some degree of point fixation (sutures/tacks) to stop the mesh from migrating and creating high recurrence rates…
The role of antibiotic prophylaxis in reducing bacterial contamination of autologous bone graft collected from implant site
2017
The aim of this study was to evaluate if antibiotic prophylaxis reduces the bacterial contamination of bone particles collected directly from the burs used for implant site preparation. Thirty-four patients underwent the surgical procedures for a total of 34 implant sites. One 1 gr. tablet of amoxicillin + clavulanic acid was given to the test group 12 hours and 1 hour before the surgery. The control group did not take antibiotic prophylaxis. Bone particles were collected and centrifuged. The suspensions were subjected to serial dilutions and each dilution was examined twice using a spatulation technique in Trypticase Soy Agar (TSA), in Sabouraud Dextrose Agar, and in Mitis Salivarius Agar …
Series of fibrinous inflammation after implantation of capsular tension rings
2014
Purpose To analyze the cause of fibrinous inflammation in eyes with capsular tension rings (CTRs) after cataract surgery. Setting Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University Mainz, Mainz, Germany. Design Retrospective case series. Methods High-performance liquid chromatography was implemented to eliminate impurities. One CTR was explanted for microbiologic examination. The pH values of the CTR and the storage solution were analyzed, Seldi and Maldi tests were performed, as well as toxicity tests with immortal cell lines. Material batches were analyzed. The organic carbon content of CTRs, detergents, and storage solutions was checked. The presence of…
Initial experience with the Sophono Alpha 1 osseointegrated implant.
2013
In the last several years, bone anchored hearing aids have proven to be useful in treating conductive and mixed unilateral or bilateral hearing loss, as well as for sensorineural unilateral hearing loss. The Sophono Alpha 1 model has the advantage of not requiring an abutment, with it being coupled by magnetism instead. We report the cases of 3 infants with congenital malformations of external and middle ear. Audiometry showed conductive hearing loss. All 3 patients were implanted with Alpha 1 model (Sophono). Patients evolved satisfactorily. After 30 days we applied the processor and the control audiometry showed a marked improvement of hearing thresholds, although without a complete closu…