Search results for "Prostheses"

showing 8 items of 88 documents

Innovative barriers for peritoneal adhesion prevention: liquid or solid? A rat uterine horn model.

2005

Objective To compare the effects of solid barriers (PDLA membrane and foil, Interceed), innovative barrier solutions (Adept and Hyalobarrier Gel, phospholipid emulsion), and Ringer’s lactate solution in preventing postsurgical peritoneal adhesions in the rat. Design Prospective, randomized experimental study. Setting Rat model in an academic research environment. Animal(s) Female, nonpregnant Wistar rats. Intervention(s) Standardized surgical injuries were applied to the parietal and visceral peritoneum and the uterine horns. The barrier agents were applied and the wound was closed. A second-look laparoscopy was performed 31 days after surgery to assess adhesion formation. Main Outcome Meas…

medicine.medical_specialtyRinger's LactatePolymersPolyestersAdhesion (medicine)Tissue AdhesionsPeritoneal DiseasesSeverity of Illness IndexIcodextrinmedicineAnimalsHyalobarrierCellulose OxidizedAdhesion preventionLactic AcidRats WistarLaparoscopymedicine.diagnostic_testSuturesbusiness.industryUterusObstetrics and GynecologyUterine hornsAdeptMembranes ArtificialProstheses and Implantsmedicine.diseaseSurgeryRatsReproductive MedicinePeritoneal adhesionEmulsionsFemaleIsotonic SolutionsPeritoneumbusinessGelsFertility and sterility
researchProduct

A regenerative 3D scaffold for inguinal hernia repair. MR imaging and histological cross evidence. Qualitative study

2021

Abstract Background Inguinal hernia is a degenerative disease occurring in a high motile surround. Stopping degeneration and promoting tissue regeneration should be the treatment goal. Groin hernias are conventionally managed with static flat meshes, mostly fixated to the delicate inguinal environment. Far from a regenerative effect, the biologic response of conventional hernia meshes is characterized by a foreign body reaction leading to a stiff/shrunken scar plate, which is often the source of unpleasant complications. Recently, a newly engineered 3D device for inguinal hernia repair – ProFlor-has been developed to produce a regenerative biological response. Unlike conventional hernia mes…

medicine.medical_specialtySwineAdipose tissueHernia InguinalGroinProsthesesDegenerative diseaseMagnetic resonance imagingmedicineAnimalsHerniaHerniorrhaphymedicine.diagnostic_testGroinbusiness.industryInguinal herniaMagnetic resonance imagingHistologyGeneral MedicineSurgical Meshmedicine.diseaseInguinal herniamedicine.anatomical_structureHernia genesisPorcine experimental modelSurgeryRadiologyForeign bodybusinessRegenerative scaffolds
researchProduct

Translational development and pre-clinical evaluation of prototype gastrointestinal mock-up devices: only robotic placement of plastic?

2020

Background: The aim of this study was to address the vision of wireless theranostic devices distributed along the gastrointestinal (GI) tract by defining design requirements, developing prototype mock-ups, and establishing a minimally invasive surgical approach for the implantation process. Methods: Questionnaires for contextual analysis and use case scenarios addressing the technical issues of an implantable GI device, a possible scenario for implantation, preparation and calibration of a device, and therapeutic usage by professionals and patients were completed and discussed by an interdisciplinary team of surgeons, engineers, and product designers. Two acute porcine experiments were cond…

medicine.medical_specialtySwineComputer scienceeducation0206 medical engineeringBiomedical Engineering02 engineering and technology01 natural sciencesTranslational Research BiomedicalRobotic Surgical ProceduresmedicineAnimalsMinimally Invasive Surgical ProceduresMedical physics010401 analytical chemistryRobotic Surgical ProceduresEquipment DesignProstheses and ImplantsGeneral Medicineequipment and supplies020601 biomedical engineering0104 chemical sciencesGastrointestinal TractPrinting Three-DimensionalPlasticsClinical evaluationJournal of Medical Engineering & Technology
researchProduct

Implant-specific follow-up imaging of treated intracranial aneurysms: TOF-MRA vs. metal artifact reduced intravenous flat panel computed tomography a…

2017

Aim To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. Methods The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n= 20; clipping: n= 15; coiling + stenting: n= 9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-ima…

medicine.medical_specialtyWilcoxon signed-rank testImage qualityComputed Tomography Angiographymedicine.medical_treatmentContrast MediaMagnetic resonance angiography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineAneurysmMcNemar's testmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesComputed tomography angiographyRetrospective Studiesmedicine.diagnostic_testbusiness.industryIntracranial AneurysmGeneral MedicineClipping (medicine)Prostheses and Implantsmedicine.diseaseImage EnhancementSurgical InstrumentsCerebral AngiographyMetalscardiovascular systemStentsImplantRadiologybusinessArtifacts030217 neurology & neurosurgeryMagnetic Resonance AngiographyFollow-Up StudiesClinical radiology
researchProduct

Methotrexate-Loaded Polymethylmethacrylate Bone Cement for Local Bone Metastasis Therapy: Pilot Animal Study in the Rabbit Patellar Groove

2008

Local chemotherapy is an option in bone metastasis treatment. On the other hand, evaluation of side effects on bone is a difficult issue in drug development and biomaterials research. Most animal models to date are inappropriate or not feasible. Rabbits are an alternative to other bigger mammals and have an appropriate bone structure compared to rats and mice. The patellar groove model of the rabbit offers a standardized and sensitive model to evaluate bone-compromising drug effects. We tested the system with a reproducible polymethacrylate implant as carrier and loaded this system with methotrexate. Three methotrexate concentrations were used in the test samples (250 mg, 1 g and 4 g per 40…

medicine.medical_specialtymedicine.medical_treatmentBone NeoplasmsPilot ProjectsMetastasisDrug DiscoverymedicineAnimalsPolymethyl MethacrylatePharmacology (medical)PharmacologyChemotherapybusiness.industryBone CementsBone metastasisPatellaProstheses and ImplantsGeneral Medicinemedicine.diseaseBone cementSurgeryPre-clinical developmentDisease Models AnimalMethotrexateInfectious DiseasesOncologyPatellaMethotrexateRabbitsImplantbusinessmedicine.drugChemotherapy
researchProduct

Effect of lumbar disc replacement on the height of the disc space and the geometry of the facet joints: a cadaver study.

2010

In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation sofware applied to CT scans before and after instrumentation. After disc replacement the mean lumbar disc height was doubled (p < 0.001). The mean angle of lordosis and the facet joint space increased by a statistically significant extent (p < 0.005 and p = 0.006, respectively). By contrast, the mean facet joint overlap was significantl…

musculoskeletal diseasesAdultMalemedicine.medical_specialtyFacet (geometry)LordosisGeometryZygapophyseal JointFacet jointLumbar discCadaverMedicineHumansOrthopedics and Sports MedicineArthroplasty ReplacementArthrographyIntervertebral DiscAgedAged 80 and overLumbar Vertebraebusiness.industryIntervertebral discAnatomyProstheses and ImplantsMiddle Agedmedicine.diseaseIntervertebral diskmedicine.anatomical_structureOrthopedic surgeryLordosisSurgeryFemaleStress MechanicalbusinessTomography X-Ray ComputedThe Journal of bone and joint surgery. British volume
researchProduct

The PROMISE study protocol: a multicenter prospective study of process optimization with interdisciplinary and cross-sectoral care for German patient…

2021

Background and purpose — Knee and hip replacement are common and increasing procedures, and an optimized care process that could be implemented in different settings would be useful. The PROMISE trial investigates whether a new care process works equally in different German settings and how the results compare with current non-standardized care. Patients and methods — This multi-center prospective mixed-method study includes 2,000 German patients receiving arthritis-related hip or knee endoprostheses. An interdisciplinary and cross-sectoral care process was developed and implemented in 3 German hospitals with different levels of care, and corresponding rehabilitation centers were included t…

musculoskeletal diseasesmedicine.medical_specialtyCare processArthroplasty Replacement HipMEDLINEHip replacement (animal)German03 medical and health sciencesDisability Evaluation0302 clinical medicineGermanySurveys and QuestionnairesmedicineHumansOrthopedics and Sports Medicine030212 general & internal medicineProspective StudiesProspective cohort studyArthroplasty Replacement KneePain MeasurementProtocol (science)Orthopedic surgeryPatient Care Team030222 orthopedicsbusiness.industryGeneral MedicineProstheses and Implantslanguage.human_languageTreatment OutcomeCross sectorallanguagePhysical therapyQuality of LifeSurgerybusinessRD701-811Research ArticleActa Orthopaedica
researchProduct

Current status and prospects conservative stem prostheses in hip-replacement surgery

2011

prostheses conservative stemhip replacement surgery proxima stem implantSettore MED/33 - Malattie Apparato Locomotore
researchProduct