Search results for "Prosthesi"

showing 10 items of 722 documents

The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements.

2003

To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs.Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery.The UMA s…

musculoskeletal diseasesAdultMaleAccuracy and precisionmedicine.medical_specialtymedicine.medical_treatmentRadiographyArthroplasty Replacement HipProsthesisRadiostereometric AnalysisForeign-Body MigrationmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingFemurFemurDigital radiographyAgedOrthodonticsReproducibilitybusiness.industryReproducibility of ResultsMiddle Agedmusculoskeletal systemSurgeryProsthesis FailureRadiographic Image EnhancementOrthopedic surgeryFemaleHip ProsthesisbusinessSkeletal radiology
researchProduct

The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.

2013

Displaced distal tibia fractures require stable fixation while minimizing secondary damage to the soft tissues by the surgical approach and implants. Antegrade intramedullary nailing has become an alternative to plate osteosynthesis for the treatment of distal metaphyseal fractures over the past two decades. While retrograde intramedullary nailing is a standard procedure in other long bone fractures, only few attempts have been made on retrograde nailing of tibial fractures. The main reasons are difficulties of finding an ideal entry portal and the lack of an ideal implant for retrograde insertion. The Retrograde Tibial Nail (RTN) is a prototype intramedullary implant developed by our group…

musculoskeletal diseasesAdultMalemedicine.medical_specialtymedicine.medical_treatmentLong boneBone NailsOsteotomyProsthesis Designlaw.inventionIntramedullary rodFixation (surgical)lawmedicineHumansTibiaGeneral Environmental ScienceAgedOsteosynthesisbusiness.industryMiddle Agedmusculoskeletal systemSurgeryBiomechanical PhenomenaFracture Fixation IntramedullaryRadiographyTibial Fracturesmedicine.anatomical_structureTreatment OutcomeGeneral Earth and Planetary SciencesFemaleImplantAnklebusinessBone PlatesInjury
researchProduct

A ten-year follow-up of the Reflection cementless acetabular component.

2008

We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…

musculoskeletal diseasesAdultmedicine.medical_specialtyAcetabulum; Adult; Aged; Aged 80 and over; Arthroplasty Replacement Hip; Bone Cements; Equipment Failure Analysis; Follow-Up Studies; Hip Joint; Humans; Middle Aged; Osteoarthritis Hip; Prosthesis Design; Prosthesis Failure; Statistics as Topic; Time Factors; Hip ProsthesisTime FactorsArthroplasty Replacement HipStatistics as TopicProsthesis DesignOsteoarthritis HipmedicineHumansOrthopedics and Sports MedicineSurvival analysisPelvisFixation (histology)AgedAged 80 and overbusiness.industryBone CementsAcetabulumMiddle AgedConfidence intervalSurgeryProsthesis FailureEquipment Failure AnalysisReflection acetabular component hipmedicine.anatomical_structureAcetabular componentRadiological weaponCohortOrthopedic surgerySurgeryHip JointHip ProsthesisbusinessFollow-Up StudiesThe Journal of bone and joint surgery. British volume
researchProduct

Primary total hip arthroplasty with fourth-generation ceramic bearings: Clinical and survival results with a minimum follow-up of 5 years.

2019

Abstract Objective To evaluate the clinical results and survival of primary hip prosthesis with ceramic delta bearings (C-C) with a minimum follow-up of 5 years. Material and method A total of 205 primary hip arthroplasties performed between 2008 and 2012 were studied. The clinical results, pre-surgical and at 5 years of follow-up were evaluated using the Harris Hip Score (HHS), the Short Form-36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the visual analogue scale (VAS). The position of the prosthetic components, periprosthetic osteolysis, loosening of the prosthetic components and ruptures of the ceramic components were studied radiologically. …

musculoskeletal diseasesCeramic bearing030222 orthopedicsWOMACbusiness.industryVisual analogue scalemedicine.medical_treatmentDentistryOsteoarthritismedicine.diseaseProsthesis03 medical and health sciencesArtroplastia total de cadera primaria Cerámica delta Delta ceramic Outcomes Primary total hip arthroplasty Resultados Supervivencia Survival0302 clinical medicineHarris Hip ScoreFourth generationMedicineOrthopedics and Sports MedicineSurgery030212 general & internal medicinebusinessTotal hip arthroplasty
researchProduct

In vitro comparison of the efficacy of two fractured implant-prosthesis screw extraction methods: Conventional versus mechanical.

2019

Abstract Statement of problem Implant-supported prostheses may be subject to esthetic, biological, or mechanical complications. Protocols for dealing with these mechanical problems are sparse. Purpose The purpose of this in vitro study was to compare the efficacy of a mechanical system for extracting fractured implant-prosthesis screws with the conventional method. Material and methods A total of 60 screws were divided into 2 groups according to their morphology (flat screws with a smooth shaft and threaded apical area and screws with a completely threaded body) and subjected to fatiguing and static load testing until fracture. The specimens were assigned to 3 operators with varying levels …

musculoskeletal diseasesDental ImplantsUltrasound deviceMaterials scienceImplant prosthesisBone Screws030206 dentistryThread (computing)Esthetics Dentalmusculoskeletal systemequipment and suppliescomputer.software_genreExtractor03 medical and health sciencesLoad testingsurgical procedures operative0302 clinical medicineCoronal planeExtraction methodsOral SurgerycomputerFracture typeBiomedical engineeringThe Journal of prosthetic dentistry
researchProduct

Redesign of a Reverse Shoulder Prosthesis: Kinematic and Mechanical Study

2014

In this work a commercial reverse shoulder prosthesis has been redesigned to improve performances in terms of range of movements of the implant and stability to dislocation. A kinematic and mechanic study has been performed using a realistic solid model of the prothesised shoulder: in particular, all the components of the prosthesis have been acquired via a 3D laser scanner and inserted in a virtual humerus-glenoid system by reproducing the common surgical procedure. The final model has been used to measure the maximum angles of abduction and rotation of the arm and the shear forces that cause dislocation. Modifications proposed to the commercial prosthesis are: a different orientation of t…

musculoskeletal diseasesEngineeringbusiness.industrymedicine.medical_treatmentWork (physics)Shear forceMechanical engineeringGeneral MedicineKinematicsRotationProsthesisOrientation (geometry)medicineDislocationbusinessInstant centre of rotationSimulationApplied Mechanics and Materials
researchProduct

The influence of lateral release on patello-femoral joint loading in knee arthroplasty

1992

Eight fresh, cadaveric knees have been fitted with four different total knee cemented prostheses. Loading forces at the bone implant fixation interface of the patella component have been measured in a knee joint testing rig by four miniaturized force transducers, before and after a lateral release of the patellar retinaculum. The lateral release resulted in a significant local force reduction in the lateral and/or proximal quadrant of the patella resection plane depending on the knee flexion angle, quadriceps tensile force direction, and the patellar prosthesis design.

musculoskeletal diseasesKnee Jointmedicine.medical_treatmentTransducersIn Vitro TechniquesKnee JointProsthesis DesignProsthesisWeight-BearingCadaverHumansMedicineOrthopedics and Sports MedicineFixation (histology)OrthodonticsLateral releasebusiness.industryPatellamusculoskeletal systemArthroplastyLigaments ArticularSurgeryPatellaKnee ProsthesisbusinessCadaveric spasmhuman activitiesInternational Orthopaedics
researchProduct

Cementless acetabular reconstruction and structural bone-grafting in dysplastic hips. Surgical technique.

2007

BACKGROUND: Studies of acetabular reconstruction with use of cement and bulk bone graft have demonstrated increasing rates of cup failure in patients with dysplastic hips seven years after total hip arthroplasty. Comparable data on the long-term results of bulk bone-grafting done in conjunction with cementless implants are limited. The aim of this study was to review the clinical and radiographic results of autologous bulk bone-grafting in conjunction with a cementless cup. METHODS: From 1987 to 1992, forty-seven patients (forty women and seven men, with an average age of 50.4 years) who had developmental dysplasia of the hip underwent fifty-six total hip arthroplasties and received a struc…

musculoskeletal diseasesMaleReoperationmedicine.medical_specialtyRadiographymedicine.medical_treatmentBone graftingTransplantation AutologousArthroplastymedicineHip DislocationHumansOrthopedics and Sports MedicineProspective StudiesSurvival rateHip dysplasiaBone Transplantationbusiness.industryAcetabulumGeneral MedicineMiddle Agedmedicine.diseaseAcetabulumSurgeryProsthesis FailureTransplantationRadiographysurgical procedures operativeTreatment OutcomeOrthopedic surgerySurgeryFemaleImplantHip ProsthesisbusinessThe Journal of bone and joint surgery. American volume
researchProduct

In Silico Analysis of Bone Tension During Fixation of the Medial Malleolus Fracture After Ankle Joint Endoprosthesis

2020

Total ankle arthroplasty (TAR) is a procedure alternative to arthrodesis which enables the biomechanical stabilization of the ankle joint. The procedure is associated with a high risk of complications, including fractures of the medial malleolus. In this study, the finite element method (FEM), based on CT examinations, was used to model the ankle fracture fixation after TAR. Three types of fracture stabilization were considered: screw, Blount staple, and both screw and Blount staple. In the in silico model, the maximum stress tension was found at prosthetic junctions with the base, cone, and talar components of the tibial prosthesis. When the fracture was stabilized with the Blount staple, …

musculoskeletal diseasesOrthodonticsbusiness.industrymedicine.medical_treatmentArthrodesisMedial sideProsthesis03 medical and health sciencesFixation (surgical)0302 clinical medicineMedial malleolusmedicine.anatomical_structureFracture fixationMedicine030212 general & internal medicineFemoral componentAnklebusiness
researchProduct

Biomechanical Analysis of a New Elbow Prosthesis

2019

Total elbow arthroplasty (TEA) is an effective and frequently used treatment for patients with debilitating elbow pathology. Total elbow prostheses have lagged behind those of the knee, hip and shoulder for different reasons, such as the high failure rate of the early designs. Concern remains regarding the longevity of TEA implants, especially in younger patients. The main cause of revision of the implant is usually related to the phenomenon of aseptic loosening mainly due to the cement-bone interface failure. Aim of this work is the biomechanical analysis of a new elbow prosthesis to investigate the mechanical behaviour at the cement-bone interface. For this reason, a musculoskeletal model…

musculoskeletal diseasesTotal elbow arthroplasty FEM Reverse engineering CADFEM030222 orthopedicsbusiness.industryElbowAseptic looseningDentistry030229 sport sciencesmusculoskeletal systemElbow prosthesisTotal elbow arthroplasty03 medical and health sciences0302 clinical medicinemedicine.anatomical_structuremedicineTotal elbow arthroplastyCADImplantSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeReverse engineeringbusiness
researchProduct