Search results for "Prosthesis Design"
showing 10 items of 245 documents
Chimney and periscope grafts observed over 2 years after their use to revascularize 169 renovisceral branches in 77 patients with complex aortic aneu…
2013
^ ^Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in theendovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelfdevices.Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; meanage 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch tovisceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiringchimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned inadvance and were not used as bailout. A standardized follow-up protocol includingcomputed tomographic angiography, laboratory testing, and clinical examination wasp…
Functional annulus remodelling using a prosthetic ring in tricuspid aortic valve repair: mid-term results
2013
OBJECTIVES: The functional aortic valve annulus (FAVA) is a complex unit with proximal (aorto-ventricular junction) and distal (sinotubular junction) components. The aim of our study was to evaluate the impact of the total FAVA remodelling, using a prosthetic ring, on mid-term clinical and echocardiographic-RESULTS:-after aortic valve repair. METHODS: Since February 2003, 250 patients with tricuspid aortic valve insufficiency (AI) underwent aortic valve repair. FAVA dilatation was treated by prosthetic ring in 52 patients, by isolated subcommissural plasty in 62, by subcommissural plasty plus ascending aortic replacement in 57 and by David's reimplantation procedure in 79. Survival rate and…
Absorb Bioresorbable Scaffold Versus Xience Metallic Stent for Prevention of Restenosis Following Percutaneous Coronary Intervention in Patients at H…
2019
Abstract Background The advent of bioresorbable vascular scaffolds (BVS) was considered as a potential improvement in percutaneous coronary intervention (PCI) after the groundbreaking development of drug eluting stents (DES). However, the clinical performance, long-term safety and efficacy of BVS in complex coronary lesions remain uncertain. COMPARE ABSORB, a multicenter, single blind, prospective randomized trial, aims to compare the clinical outcomes between the Absorb BVS and Xience everolimus-eluting metallic stent (EES) in patients with coronary artery disease and a high risk of restenosis. Design COMPARE ABSORB is designed to enroll 2100 patients at up to 45 European sites. Enrolled p…
New intramedullary locking nail for olecranon fracture fixation--an in vitro biomechanical comparison with tension band wiring.
2010
The aim of this study was to determine the difference in displacement of a newly designed intramedullary olecranon fracture fixation device compared with multifilament tension band wiring after 4 cycles and 300 cycles of dynamic continuous loading.In eight pairs of fresh-frozen cadaver ulnae, oblique olecranon fractures were created and stabilized using either newly designed intramedullary olecranon nail or multifilament tension band wiring. The specimens were then subjected to continuous dynamic loading (from 25 N to 200 N) using matched pairs of cadaveric upper extremities. The Wilcoxon test was used to determine statistical differences of the displacement in the fracture gap.After 4 cycl…
Modeling Right Ventricle Failure After Continuous Flow Left Ventricular Assist Device: A Biventricular Finite-Element and Lumped-Parameter Analysis
2017
The risk of right ventricle (RV) failure remains a major contraindication for continuous-flow left ventricular assist device (CF-LVAD) implantation in patients with heart failure. It is therefore critical to identify the patients who will benefit from early intervention to avoid adverse outcomes. We sought to advance the computational modeling description of the mechanisms underlying RV failure in LVAD-supported patients. RV failure was studied by computational modeling of hemodynamic and cardiac mechanics using lumped-parameter and biventricular finite element (FE) analysis. Findings were validated by comparison of bi-dimensional speckle-tracking echocardiographic strain assessment of the …
Impact of obesity on adverse in-hospital outcomes in patients undergoing percutaneous mitral valve edge-to-edge repair using MitraClip® procedure - R…
2019
Background and aim: The number of percutaneous edge-to-edge mitral regurgitation (MR) valve repairs with MitraClip® implantations increased exponentially in recent years. Studies have suggested an obesity survival paradox in patients with cardiovascular diseases. We investigated the influence of obesity on adverse in-hospital outcomes in patients with MitraClip® implantation. Methods and results: We analyzed data on characteristics of patients and in-hospital outcomes for all percutaneous mitral valve repairs using the edge-to-edge MitraClip®-technique in Germany 2011–2015 stratified for obesity vs. normal-weight/over-weight. The nationwide inpatient sample comprised 13,563 inpatients under…
Silicone-Silver Penile Prosthesis: Description, Operative Approach and Results
1980
A silicone penile prosthesis in which silver wires are embedded to allow for voluntary bending of the penis for urination and resting position and for straightening for intercourse is described. The implantation is done via a hemicircular incision on the dorsum of the penis in the sulcus coronarius. Buck's fascia is identified and opened, and the corpora are dilated up to 30F. After the exact length is determined with a special sizer the prosthesis is slipped into each corpus cavernosum. The advantage of this approach is the optimal insertion of the prosthesis distal to the sulcus coronarius, thereby preventing kinking of the glans during intercourse. Our experiences with the implantation i…
A Human-Humanoid Interaction Through the Use of BCI for Locked-In ALS Patients Using Neuro-Biological Feedback Fusion.
2018
This paper illustrates a new architecture for a human–humanoid interaction based on EEG-brain computer interface (EEG-BCI) for patients affected by locked-in syndrome caused by Amyotrophic Lateral Sclerosis (ALS). The proposed architecture is able to recognise users’ mental state accordingly to the biofeedback factor $\text {B}_{\text f}$ , based on users’ attention, intention, and focus, that is used to elicit a robot to perform customised behaviours. Experiments have been conducted with a population of eight subjects: four ALS patients in a near locked-in status with normal ocular movement and four healthy control subjects enrolled for age, education, and computer expertise. The results s…
Single-blind randomized clinical trial to evaluate clinical and radiological outcomes after one year of immediate versus delayed implant placement su…
2013
Purpose: To evaluate and compare peri-implant health, marginal bone loss and success of immediate and delayed implant placement for rehabilitation with full-arch fixed prostheses. Material and Methods: The present study was a prospective, randomized, single-blind, clinical preliminary trial. Patients were randomized into two treatment groups. In Group A implants were placed immediately post-extraction and in Group B six months after extraction. The following control time-points were established: one week, six months and twelve months after loading. Measurements were taken of peri-implant crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified …
Fitting Scleral Lenses Less Than 15 mm in Diameter: A Review of the Literature.
2020
OBJECTIVE To perform a comprehensive review of the current and historical scientific literature on fitting small scleral lenses (diameter <15 mm) and clarifying their advantages and disadvantages, in addition to their clinical applications. METHODS The literature search was performed through PubMed from MEDLINE. RESULTS Eleven studies of case series (258 eyes) were found. Indications were similar to those of larger scleral lenses, 74% for corneal irregularities (mainly keratoconus), whereas 26% for ocular surface diseases. In the studies on cases of irregular corneas, visual acuity improved significantly regarding the values before and after fitting the lenses (mean, 0.4-0.03 logMar, respec…