Search results for "Prosthesis Design"
showing 10 items of 245 documents
The implant-supported milled bar overdenture : a literature review
2008
Purpose: This bibliographical review aims to determine the present situation of the implant-supported milled bar overdenture as a therapeutic option in implantology, as well as to set and compare the techniques and materials currently used for making them. Materials and methods: By searching the main electronic bibliographical data in indexed Medline articles, we obtained a total number of 20 articles that fulfilled the requirements of this bibliographical review. Results: The implant-supported milled bar overdenture offers excellent long-term successful results, although complication rates are higher in emergency cases of patients initially planned for a fixed prosthesis. Krenmair and coll…
Peri-implant defect grafting with autogenous bone or bone graft material in immediate implant placement in molar extraction sites-1- to 3-year result…
2020
Objectives To evaluate the survival rate, the orobuccal bone resorption and stability of peri-implant hard and soft tissues following immediate implant placement of wide diameter implants in molar extraction sites and peri-implant defect grafting with autogenous bone (AB) or biphasic bone graft material (BBGM) with 1- to 3-year follow-up examinations. Material and methods Fifty wide diameter implants were placed in 50 patients immediately into molar extraction sockets by a flapless approach. Peri-implant defect augmentation was performed randomized with either AB or BBGM. Primary outcome variable was implant survival. Marginal bone level changes, orobuccal width of the alveolar crest, probi…
Tilted implants for the restoration of posterior mandibles with horizontal atrophy: An alternative treatment
2013
Purpose Horizontal atrophy in the posterior mandible presents serious limitations on conventional implant placement. The purpose of this study was to evaluate the use of tilted implants angled in a buccolingual direction for restoring atrophic posterior mandibular sectors. Materials and Methods A cohort study was performed of 25 patients who had partial prostheses supported by more than 1 implant (≥1 tilted and 1 axial implant) to restore molar areas in the mandible. When the bone thickness was at least 5 mm, axial implants were placed; when the alveolar ridge was narrower, the implant was placed with tilted angulation. The beds for these tilted implants were prepared using a lingual approa…
Evaluation of the healing of precoated vascular dacron prostheses.
1991
Knitted and woven Dacron grafts commercially coated with bovine collagen, gelatin and human albumin were implanted end-to-side between the infrarenal aorta and the bifurcation in 35 growing pigs. Grafts were explanted after 4, 8 and 12 weeks and compared to 6 uncoated knitted prostheses preclotted with blood that served as a control. Uncoated grafts rapidly developed a firmly attached neointima lined with endothelium. Compared with coated grafts the thrombus-free area of uncoated grafts was significantly larger (P less than 0.05). The slow resorption of albumin resulted in a delayed and incomplete neointimal healing and failing graft incorporation. Although the bovine collagen was only mini…
Short stem total hip arthroplasty: Potential explanations for persistent post-surgical thigh pain.
2017
Abstract: Short stem uncemented femoral implants were developed with the aim of preserving proximal bone stock for future revisions, improving biomechanical reconstruction, aiding insertion through smaller incisions and potentially decreasing or limiting the incidence of thigh pain. Despite all the advantages of short stem designs, it remains unclear whether they are able to limit post-surgical thigh pain. In patients with short stem hip arthroplasty and persistent thigh pain, it is of the utmost importance to understand the potential etiologies of this chronic pain for selecting the appropriate treatment strategy. Therefore, this manuscript explores the hypothetical etiologies of persisten…
In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.
2015
Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…
Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering
2012
To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…
Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.
2016
Purpose To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF). Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd). Results The far focus of the bifocal IOL yielded higher volume values at all spati…
Digital protocol for creating a virtual gingiva adjacent to teeth with subgingival dental preparations.
2019
Abstract Purpose This article describes a digital technique used to record gingival emergence profiles modeled for the prosthetic restoration of teeth prepared using biologically oriented preparation technique (BOPT). Materials and methods The description of the technique of intraoral recording, manipulation of digital files, and chairside protocol of prosthetic restorations is developed in the present manuscript on two anterior teeth treated with vertical and subgingival dental preparations for restoration with ceramic crowns. The manipulation of the digital files registered with an intraoral scanner with software that allows its alignment (best-fit) and the performance boolean of operatio…
Retrograde nailing versus locking plate osteosynthesis of proximal humeral fractures: a biomechanical study
2011
Background In locking plate osteosynthesis of proximal humeral fractures, secondary varus malalignment is a specific complication. Retron nails (Tantum AG, Neumunster, Germany), among others, have been designed to improve medial support of the calcar humeri. The aim of our biomechanical study was to examine whether Retron nails provide increased stiffness for axial loads and adequate stiffness for torsional loads when compared with Philos plates (Synthes AG, Umkirch, Germany). Materials and methods Twenty-two fresh-frozen paired humeri were collected. After potting the specimens, intact bones were exposed to sinusoidal axial (10-120 N) and torsional (±2.5 Nm) loading for 8 cycles to calcula…