Four color-measuring devices compared with a spectrophotometric reference system
2009
Abstract Objectives The objective of this study was to compare the L*C*h° color coordinates of dental color-measuring devices with those of a spectrophotometric reference system. Methods The International Commission on Illumination (CIE) L*C*h° color coordinates of ceramic samples, matching the colors of the VITA Linearguide, were recorded using four color-measuring devices (VITA Easyshade (A), VITA Easyshade compact (B), Degudent Shadepilot (C), X-Rite Shadevision (D)) and a spectrophotometric reference system under standardized test conditions. The intraclass correlation coefficients, regression lines with coefficients of determination, and mean deviations of the dental color-measuring de…
Nickel release after implantation of the Amplatzer occluder.
2003
Background Transcatheter closure of atrial septal defects is a new and less traumatic technique than open heart surgery. In recent years, patients with a patent foramen ovale sustaining potential paradoxical embolism have also become candidates for interventional closure devices. One of the more popular occluding devices is the Amplatzer septal occluder, which, like many other occluders, is made of nitinol. Nitinol-based alloys are widely used in medical products, for example, in orthopedics and orthodontics. However, the clinical use of nitinol, which contains 55% nickel, is still controversial because of concerns about its biocompatibility. Therefore, we examined the systemic nickel relea…
Implantation of a custom intraocular lens with a 30-diopter torus for the correction of high astigmatism after penetrating keratoplasty.
2003
Abstract We present a 62-year-old woman who had implantation of an intraocular lens (IOL) with a torus of 30.0 diopters (D) in an eye after penetrating keratoplasty. The patient presented with cataract and a best corrected visual acuity of 20/400. Penetrating keratoplasty was performed in 1975 because of decompensated keratoconus. With a clear but inferiorly decentered corneal graft, visual acuity was limited because of keratoplasty-related high corneal astigmatism of 22.5@156 that could not be successfully treated with spectacles or contact lenses. A custom toric IOL with –30.0 D of cylindrical power was implanted in the capsular bag via a sclerocorneal tunnel incision. Additionally, a sph…
Narrow-diameter implants: Are they a predictable treatment option? A literature review
2013
Objective: To evaluate the predictability of narrow-diameter implants as a treatment option in routine clinical practice. A literature review was performed of studies reporting clinical results obtained with these implants. Survival rates, peri-implant bone loss and related complications were evaluated. The working hypothesis was that narrow-diameter implants offer clinical results similar to those obtained with implants of greater diameter. Material and Methods: A Medline-PubMed search covering the period between 2002 and 2012 was carried out. Studies published in English and with a follow-up period of at least 12 months were considered for inclusion. A manual search was also conducted in …
Surface Topographies of Glaucoma Drainage Devices and Their Influence on Human Tenon Fibroblast Adhesion
2010
PURPOSE. This study was performed to investigate the surface topography of different glaucoma drainage devices and to determine the effects of surface roughness on cell adhesion of cultured human tenon fibroblasts.METHODS. The surface topography of four widely used devices (Ahmed FP7 and Ahmed S-2; New World Medical, Inc., Rancho Cucamonga, CA; Baerveldt BG101-350; Advanced Medical Optics, Irvine, CA; and Molteno S1; Molteno Ophthalmic Ltd., Dunedin, New Zealand) was investigated by scanning electron microscopy, and roughness was quantified by white-light confocal microscopy. Cells were grown for 72 hours on the surfaces of implants affixed to standard culture dishes. The cells were labeled…
Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts
2020
Abstract Introduction Spontaneous acute aortic syndrome (IAAS) is rarely localized in the infrarenal aorta. The endovascular approach is preferred over conventional open surgery with fewer complications. However, dedicated endovascular devices for IAAS treatment are unavailable. The aim was to report a large single-center experience using unibody stent-grafts to address IAAS. Methods From April 2016 to March 2019, a retrospective analysis of patients presenting spontaneous and isolated IAAS was performed. Patients addressed with the unibody stent-graft (AFX endovascular AAA system; Endologix Inc., Irvine, CA) were included in the study. Indications to IAAS treatment were persistent symptoms…
Biodegradable polymer-coated thin strut sirolimus- -eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population.
2021
Background: The number of patients with diabetes mellitus (DM) presenting with coronary artery disease is increasing and accounts for more than 30% of patients undergoing percutaneous coronary interventions (PCI). The biodegradable polymer drug-eluting stents were developed to improve vascular healing. It was sought herein, to determine 1-year clinical follow-up in patients with DM treated with the thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus durable coating everolimus-eluting stent (DP-EES). Methods: Patients were retrospectively analyzed with DM were treated with either a BP-SES (ALEX™, Balton, Poland, n = 670) or a DP-EES (XIENCE™, Abbott, USA, n = 884)…
Comparison of One-Year Outcomes Between the ihtDEStiny BD Stent and the Durable-Polymer Everolimus- and Zotarolimus-Eluting Stents: A Propensity-Scor…
2021
Abstract Objectives We sought to evaluate clinical outcomes in patients treated with the drug-eluting stent ihtDEStiny BD. Background The ihtDEStiny BD stent is a metallic sirolimus eluting stent with a biodegradable polymer with both drug and polymer coating the abluminal surface of the stent and balloon. Methods In this study, the clinical outcomes of a multicenter prospective registry of patients treated with this stent (DEStiny group) were analyzed and compared with those of a control group of patients treated with durable polymer everolimus or zotarolimus eluting stents (CONTROL group) paired by propensity score matching . Primary outcome was the target vessel failure (TVF) at 12 month…
Modern Strategies in the Prevention of Implant-Associated Infections
2005
The application of medical devices either for temporary or permanent use has become an indispensible part of almost all fields of medicine. However, foreign bodies are associated with a substantial risk of bacterial and fungal infections. Implant-associated infections significantly contribute to the still increasing problem of nosocomial infections. To reduce the incidence of such infections, specific guidelines providing evidence-based recommendations and comprising both technological and nontechnological strategies for prevention have been established. Strict adherence to hygienic rules during insertion or implantation of the device are aspects of particular importance. Besides such basi…
Medicated hydrogels of hyaluronic acid derivatives for use in orthopedic field.
2013
Physical hydrogels have been obtained from hyaluronic acid derivatized with polylactic acid in the presence or in the absence of polyethylene glycol chains. They have been extemporarily loaded with antibacterial agents, such as vancomycin and tobramycin. These medicated hydrogels have been used to coat titanium disks (chosen as simple model of orthopedic prosthesis) and in vitro studies in simulated physiological fluid have been performed as a function of time and for different drug loading and polymer concentration values. Sterilization process performed on the hydrogels does not change their rheological behavior and release properties as well as the chemical structure of starting copolyme…