Search results for "Prosthesis Design"

showing 10 items of 245 documents

Four color-measuring devices compared with a spectrophotometric reference system

2009

Abstract Objectives The objective of this study was to compare the L*C*h° color coordinates of dental color-measuring devices with those of a spectrophotometric reference system. Methods The International Commission on Illumination (CIE) L*C*h° color coordinates of ceramic samples, matching the colors of the VITA Linearguide, were recorded using four color-measuring devices (VITA Easyshade (A), VITA Easyshade compact (B), Degudent Shadepilot (C), X-Rite Shadevision (D)) and a spectrophotometric reference system under standardized test conditions. The intraclass correlation coefficients, regression lines with coefficients of determination, and mean deviations of the dental color-measuring de…

medicine.diagnostic_testProsthesis ColoringIntraclass correlationAnalytical chemistryColorReproducibility of ResultsRepeatabilityDental Prosthesis DesignSpectrophotometrySpectrophotometryLinear regressionLinear ModelsmedicineMeasuring instrumentHumansTooth DiscolorationColorimetryColorimetryGeneral DentistryColor coordinatesHueMathematicsJournal of Dentistry
researchProduct

Nickel release after implantation of the Amplatzer occluder.

2003

Background Transcatheter closure of atrial septal defects is a new and less traumatic technique than open heart surgery. In recent years, patients with a patent foramen ovale sustaining potential paradoxical embolism have also become candidates for interventional closure devices. One of the more popular occluding devices is the Amplatzer septal occluder, which, like many other occluders, is made of nitinol. Nitinol-based alloys are widely used in medical products, for example, in orthopedics and orthodontics. However, the clinical use of nitinol, which contains 55% nickel, is still controversial because of concerns about its biocompatibility. Therefore, we examined the systemic nickel relea…

medicine.medical_specialtyHeart septal defectCardiac CatheterizationHeart diseasebusiness.industryAmplatzer Septal Occluderchemistry.chemical_elementProstheses and Implantsmedicine.diseaseProsthesis DesignAtrial septal defectsHeart Septal Defects AtrialSurgeryNickelParadoxical embolismchemistryNickelPatent foramen ovalemedicineAlloysHumansCardiology and Cardiovascular MedicinebusinessComplicationAmerican heart journal
researchProduct

Implantation of a custom intraocular lens with a 30-diopter torus for the correction of high astigmatism after penetrating keratoplasty.

2003

Abstract We present a 62-year-old woman who had implantation of an intraocular lens (IOL) with a torus of 30.0 diopters (D) in an eye after penetrating keratoplasty. The patient presented with cataract and a best corrected visual acuity of 20/400. Penetrating keratoplasty was performed in 1975 because of decompensated keratoconus. With a clear but inferiorly decentered corneal graft, visual acuity was limited because of keratoplasty-related high corneal astigmatism of 22.5@156 that could not be successfully treated with spectacles or contact lenses. A custom toric IOL with –30.0 D of cylindrical power was implanted in the capsular bag via a sclerocorneal tunnel incision. Additionally, a sph…

medicine.medical_specialtyKeratoconusRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentEye diseaseVisual AcuityIntraocular lensAstigmatismKeratoconusProsthesis DesignCataractHigh astigmatismLens Implantation IntraocularOphthalmologymedicineHumansDioptreLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismCorneal TopographyMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Narrow-diameter implants: Are they a predictable treatment option? A literature review

2013

Objective: To evaluate the predictability of narrow-diameter implants as a treatment option in routine clinical practice. A literature review was performed of studies reporting clinical results obtained with these implants. Survival rates, peri-implant bone loss and related complications were evaluated. The working hypothesis was that narrow-diameter implants offer clinical results similar to those obtained with implants of greater diameter. Material and Methods: A Medline-PubMed search covering the period between 2002 and 2012 was carried out. Studies published in English and with a follow-up period of at least 12 months were considered for inclusion. A manual search was also conducted in …

medicine.medical_specialtyMEDLINEDentistryOdontologíaReviewProsthesis DesignmedicineHumansProsthesis designRoutine clinical practiceGeneral DentistryDental ImplantsImplantes dentalesbusiness.industryTreatment options:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludSurgeryOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryOdontología restauradorabusinessImplantologyForecastingRevisiones sistemáticas
researchProduct

Surface Topographies of Glaucoma Drainage Devices and Their Influence on Human Tenon Fibroblast Adhesion

2010

PURPOSE. This study was performed to investigate the surface topography of different glaucoma drainage devices and to determine the effects of surface roughness on cell adhesion of cultured human tenon fibroblasts.METHODS. The surface topography of four widely used devices (Ahmed FP7 and Ahmed S-2; New World Medical, Inc., Rancho Cucamonga, CA; Baerveldt BG101-350; Advanced Medical Optics, Irvine, CA; and Molteno S1; Molteno Ophthalmic Ltd., Dunedin, New Zealand) was investigated by scanning electron microscopy, and roughness was quantified by white-light confocal microscopy. Cells were grown for 72 hours on the surfaces of implants affixed to standard culture dishes. The cells were labeled…

medicine.medical_specialtyMaterials scienceScanning electron microscopeConfocalSurface finishProsthesis Designlaw.inventionConfocal microscopylawBone plateMicroscopyCell AdhesionSurface roughnessmedicineHumansFasciaGlaucoma Drainage ImplantsCell adhesionCells CulturedMicroscopy ConfocalFibroblastsSurgeryMicroscopy Electron ScanningCell DivisionProtein BindingBiomedical engineeringInvestigative Opthalmology & Visual Science
researchProduct

Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts

2020

Abstract Introduction Spontaneous acute aortic syndrome (IAAS) is rarely localized in the infrarenal aorta. The endovascular approach is preferred over conventional open surgery with fewer complications. However, dedicated endovascular devices for IAAS treatment are unavailable. The aim was to report a large single-center experience using unibody stent-grafts to address IAAS. Methods From April 2016 to March 2019, a retrospective analysis of patients presenting spontaneous and isolated IAAS was performed. Patients addressed with the unibody stent-graft (AFX endovascular AAA system; Endologix Inc., Irvine, CA) were included in the study. Indications to IAAS treatment were persistent symptoms…

medicine.medical_specialtyOriginal Scientific Report030204 cardiovascular system & hematologyProsthesis DesignSettore MED/22 - Chirurgia VascolareInfrarenal acute aortic syndromeunibody stent-graftBlood Vessel Prosthesis Implantation03 medical and health sciencesAortic aneurysm0302 clinical medicineintramural hematoma.Blood vessel prosthesismedicine.arterymedicineHumansaortic dissection penetrating aortic ulcercardiovascular diseasesAorta Abdominal030212 general & internal medicineRetrospective StudiesAcute aortic syndromebusiness.industryEndovascular ProceduresAbdominal aortaVascular surgerymedicine.diseaseBlood Vessel ProsthesisSurgeryStenosissurgical procedures operativeTreatment OutcomeCardiothoracic surgeryendovascularStentsSurgerybusinessAortic Aneurysm AbdominalAbdominal surgeryWorld Journal of Surgery
researchProduct

Biodegradable polymer-coated thin strut sirolimus- -eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population.

2021

Background: The number of patients with diabetes mellitus (DM) presenting with coronary artery disease is increasing and accounts for more than 30% of patients undergoing percutaneous coronary interventions (PCI). The biodegradable polymer drug-eluting stents were developed to improve vascular healing. It was sought herein, to determine 1-year clinical follow-up in patients with DM treated with the thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus durable coating everolimus-eluting stent (DP-EES). Methods: Patients were retrospectively analyzed with DM were treated with either a BP-SES (ALEX™, Balton, Poland, n = 670) or a DP-EES (XIENCE™, Abbott, USA, n = 884)…

medicine.medical_specialtyPercutaneousPolymersmedicine.medical_treatmentPopulation030204 cardiovascular system & hematologyProsthesis DesignCoronary artery disease03 medical and health sciences0302 clinical medicinePercutaneous Coronary InterventionInternal medicineAbsorbable ImplantsDiabetes MellitusMedicineHumansMyocardial infarctionEverolimuseducationRetrospective StudiesSirolimuseducation.field_of_studybusiness.industryStentPercutaneous coronary interventionCardiovascular AgentsDrug-Eluting StentsGeneral Medicinemedicine.diseaseInterventional CardiologySurgeryTreatment OutcomeSirolimusConventional PCICardiologyPolandCardiology and Cardiovascular Medicinebusinessmedicine.drugCardiology journal
researchProduct

Comparison of One-Year Outcomes Between the ihtDEStiny BD Stent and the Durable-Polymer Everolimus- and Zotarolimus-Eluting Stents: A Propensity-Scor…

2021

Abstract Objectives We sought to evaluate clinical outcomes in patients treated with the drug-eluting stent ihtDEStiny BD. Background The ihtDEStiny BD stent is a metallic sirolimus eluting stent with a biodegradable polymer with both drug and polymer coating the abluminal surface of the stent and balloon. Methods In this study, the clinical outcomes of a multicenter prospective registry of patients treated with this stent (DEStiny group) were analyzed and compared with those of a control group of patients treated with durable polymer everolimus or zotarolimus eluting stents (CONTROL group) paired by propensity score matching . Primary outcome was the target vessel failure (TVF) at 12 month…

medicine.medical_specialtyPolymersmedicine.medical_treatment030204 cardiovascular system & hematologyProsthesis DesignCoronary artery disease03 medical and health sciences0302 clinical medicinePercutaneous Coronary InterventionAbsorbable ImplantsmedicineClinical endpointHumansZotarolimus030212 general & internal medicineMyocardial infarctionEverolimusPropensity ScoreSirolimusEverolimusbusiness.industryStentDrug-Eluting StentsGeneral Medicinemedicine.diseaseSurgeryTreatment OutcomeDrug-eluting stentPropensity score matchingCardiology and Cardiovascular Medicinebusinessmedicine.drugCardiovascular revascularization medicine : including molecular interventions
researchProduct

Modern Strategies in the Prevention of Implant-Associated Infections

2005

The application of medical devices either for temporary or permanent use has become an indispensible part of almost all fields of medicine. However, foreign bodies are associated with a substantial risk of bacterial and fungal infections. Implant-associated infections significantly contribute to the still increasing problem of nosocomial infections. To reduce the incidence of such infections, specific guidelines providing evidence-based recommendations and comprising both technological and nontechnological strategies for prevention have been established. Strict adherence to hygienic rules during insertion or implantation of the device are aspects of particular importance. Besides such basi…

medicine.medical_specialtyProsthesis-Related InfectionsFuture studiesmedicine.drug_class0206 medical engineeringAntibioticsBiomedical EngineeringMedicine (miscellaneous)New materialsBioengineering02 engineering and technologyBiologyProsthesis DesignBacterial AdhesionBiomaterialsCoated Materials BiocompatiblemedicineHumansConnective Tissue ProteinsIntensive care medicineForeign BodiesInfection ControlGeneral Medicine021001 nanoscience & nanotechnologyAntimicrobial020601 biomedical engineeringAnti-Bacterial AgentsSurgeryPractice Guidelines as TopicEquipment Contamination0210 nano-technologyThe International Journal of Artificial Organs
researchProduct

Medicated hydrogels of hyaluronic acid derivatives for use in orthopedic field.

2013

Physical hydrogels have been obtained from hyaluronic acid derivatized with polylactic acid in the presence or in the absence of polyethylene glycol chains. They have been extemporarily loaded with antibacterial agents, such as vancomycin and tobramycin. These medicated hydrogels have been used to coat titanium disks (chosen as simple model of orthopedic prosthesis) and in vitro studies in simulated physiological fluid have been performed as a function of time and for different drug loading and polymer concentration values. Sterilization process performed on the hydrogels does not change their rheological behavior and release properties as well as the chemical structure of starting copolyme…

medicine.medical_specialtyProsthesis-Related InfectionsPolymersPolyestersPharmaceutical SciencePolyethylene glycolengineering.materialProsthesis Designcomplex mixturesPolyethylene Glycolschemistry.chemical_compoundCoatingPolylactic acidVancomycinHyaluronic acidmedicineHumansOrthopedic ProceduresFemurLactic AcidHyaluronic AcidCells CulturedSkinchemistry.chemical_classificationTitaniumChemistrytechnology industry and agricultureSterilizationHydrogelsPolymerFibroblastsSurgeryAnti-Bacterial AgentsPolyesterSelf-healing hydrogelsengineeringTobramycinImplantRheologyBiomedical engineeringInternational journal of pharmaceutics
researchProduct