Search results for "Prosthesis Design"
showing 10 items of 245 documents
Modified fixation free plug technique using a new 3D multilamellar implant for inguinal hernia repair: a retrospective study of a single operator cas…
2013
Aim: Implant fixation, mesh shrinkage and poor quality of tissue ingrowth are unresolved issues in modern hernia repair. Many complications reported in the literature such as bleeding, nerve entrapment, hematoma, pain, discomfort, and testicular complications, are considered to be a direct results of implant fixation. This article describes the outcomes of a procedure carried out using a handcrafted implant that addresses the issues consequent to point fixation. Methods: This was a retrospective study on the short, medium and long-term results of placing a-modified, fixation free three-dimensional polypropylene implant in 61 patients who underwent inguinal hernia repair using a novel delive…
Influence of plasma cleaning procedure on the interaction between soft tissue and abutments: a randomized controlled histologic study
2016
Introduction Plasma application can lead to an improved adhesion between soft tissue and abutments and promotes cell spreading. Objective A triple-blinded randomized controlled clinical trial was performed to in vivo test the effect of cleaning abutment titanium surfaces with plasma of argon on cell adhesion and collagen fiber orientation at an early healing time. Material and methods Thirty healthy patients with 30 submerged implants, at the second surgery, randomly received either a specially designed abutment with no additional treatment (as they come from industry; control group, G1) or cleaned by plasma of argon (test group, G2). Two weeks thereafter, a small biopsy including abutment …
Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction.
2013
Purpose To evaluate the efficacy, predictability, safety, and stability of a new-model posterior chamber Implantable Collamer Lens phakic intraocular lens (pIOL) (V4c Visian) to correct myopia. Setting Private practice, Oviedo, Spain. Design Case series. Methods This study enrolled patients who had implantation of a new pIOL design with a central hole for more natural aqueous flow, eliminating the need for neodymium:YAG iridotomy or peripheral iridectomy. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refractive error, intraocular pressure (IOP), endothelial cell count, central vault, and adverse events were evaluated 6 months postoperatively. Results The study enroll…
Multiple periscope and chimney grafts to treat ruptured thoracoabdominal and pararenal aortic aneurysms
2011
Purpose: To report midterm outcomes after urgent endovascular repair of ruptured pararenal or thoracoabdominal aortic aneurysms using multiple periscope and chimney grafts to preserve renovisceral branch perfusion and facilitate aneurysm exclusion. Methods: Nine consecutive men (mean age 72614 years, range 40–88) presenting with ruptured thoracoabdominal (n56), pararenal (n52), or infrarenal (n51) aortic aneurysm underwent urgent endovascular repair with at least 1 periscope graft delivered via a transfemoral access; chimney grafts were installed from an axillary access. In all, 17 periscope and 7 chimney grafts were used to reperfuse 11 renal and 13 visceral arteries in the 9 patients. The…
Survival of immediately versus delayed loaded short implants: a prospective case series study
2015
Background: To assess and compare survival rates of immediately and delayed loaded short implants (7 mm) in free ends of a partially edentulous jaw with moderate-severe alveolar bone resorption. Material and Methods: 24 patients with atrophic edentulous free-ends were included in this prospective study. Four study groups were monitored monthly and their behavior was evaluated: bridges supported only by short implants and mixed short and long implant bridge groups, both with immediate and delayed loading. Failures, bone loss, probing depth and bleeding on probing were evaluated. Results: 54 Mk III Shorty TiU and 15 Brånemark System®MK III TiU implants with a length longer than 7mm were inclu…
Post-LASIK Visual Quality With a Corneoscleral Contact Lens to Treat Irregular Corneas.
2015
To evaluate the visual quality results of fitting a corneoscleral contact lens with multiaspheric geometry design (MAGD CScL) in subjects with irregular corneas after laser-assisted in situ keratomileusis (LASIK) surgery.From a database of patients evaluated for scleral contact lenses, we identified those with irregular corneas and visual problems after they underwent LASIK surgery for correcting myopia. They manifested unsatisfactory visual quality with their current contact lenses or glasses. Therefore, a MAGD CScL was fitted and monitored according to standardized fitting methodology. A diagnostic trial set was used in the fitting process. Visual acuity (VA), subjective visual quality (S…
Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes.
2009
PURPOSE To determine the differences in refractive and visual results obtained in eyes with high and low myopia after multifocal intraocular lens (IOL) implantation. METHODS Monocular visual acuity for distance and near, with and without distance correction, and photopic and mesopic contrast sensitivity were measured at 6 months after surgery in 152 myopic eyes implanted with the AcrySof ReSTOR Natural (SN60D3) IOL. Two groups were created: high and low myopia (76 eyes in each). RESULTS Monocular best distance-corrected visual acuity was 0.02+/-0.06 logMAR for low myopes and 0.05+/-0.09 logMAR for high myopes. Monocular best distance-corrected near visual acuity was 0.04+/-0.05 and 0.07+/-0…
Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens
2005
Purpose To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Twenty-two myopic eyes and 9 hyperopic eyes were included in the study. The mean age of the 2 groups was 34 years and 40 years, respectively. The scotopic pupil size was measured with a handheld infrared pupillometer (Colvard, Oasis Medical) before and 6 months after implantation of the TPIOL. All examinations were performed under scotopic conditions after 2 minutes of dark adaptation with the fellow eye covered. Intraindi…
Incidence of heterotopic ossification in minimally invasive short-stem THA using the modified anterolateral approach.
2017
Introduction Heterotopic ossification (HO) is known to be a common complication after total hip arthroplasty (THA). The minimal invasive (MIS) modified anterolateral approach has become popular in combination with a short stem. We analysed the incidence of HO following short-stem THA using this approach in combination with a postoperative administration of nonsteroidal anti-inflammatory drugs (NSAIDs). Materials and methods 216 short stems were implanted in 162 patients. NSAIDs were administered for 2 weeks after surgery in 154 patients (95.1%). Standardised pre- and postoperative radiographic imaging was done at 2-year follow-up. HO was analysed according to the Brooker classification. Inf…
Soft and hard tissue alterations around implants placed in an alveolar ridge with a sloped configuration.
2012
Aim: The aim of this study was to evaluate soft and hard tissue alterations around implants placed in healed, sloped ridge sites. Materials and methods: In this prospective multi-center study, 65 patients between 20 and 74 years of age and with a need for a single tooth replacement were included. All patients presented with a recipient implant site demonstrating a lingual‐buccal bone height discrepancy of 2.0‐5.0 mm and with a neighboring tooth on its mesial aspect. Implant placement (OsseoSpeed Profile implants; Astra Tech AB, M! olndal, Sweden) was performed using a non-submerged installation procedure. The implants were placed in such a way that the sloped part of the device was located …