Implantation of a polycaprolactone scaffold with subchondral bone anchoring ameliorates nodules formation and other tissue alterations
2015
Purpose: Articular cartilage has limited repair capacity. Two different implant devices for articular cartilage regeneration were tested in vivo in a sheep model to evaluate the effect of subchondral bone anchoring for tissue repair. Methods: The implants were placed with press-fit technique in a cartilage defect after microfracture surgery in the femoral condyle of the knee joint of the sheep and histologic and mechanical evaluation was done 4.5 months later. The first group consisted of a biodegradable polycaprolactone (PCL) scaffold with double porosity. The second test group consisted of a PCL scaffold attached to a poly(L-lactic acid) (PLLA) pin anchored to the subchondral bone. Result…
A prospective, multi-center, practice-based cohort study on all-ceramic crowns
2021
The aim of this prospective, multi-center, practice-based cohort study was to analyze factors associated with the success of all-ceramic crowns.All-ceramic crowns placed in a practice-based research network ([Ceramic Success Analysis, AG Keramik) were analyzed. Data from 1254 patients with (mostly in-office CAD/CAM) all-ceramic crowns placed by 101 dentists being followed up for more than 5 years were evaluated. At the last follow-up visit crowns were considered as successful (not failed) if they were sufficient, whereas crowns were considered as survived (not lost) if they were still in function. Multi-level Cox proportional hazards models were used to evaluate the association between a ra…
Bioactive Glass-Ceramics in Middle Ear Surgery An 8-Year Review
1988
An 8-year follow-up of Ceravital middle ear prostheses showed there was extremely good tolerance in the middle ear space. Incompatibility phenomena were not observed, and inflammatory reactions were neither caused nor supported by the implants. The tympanoplasties were always performed without interposition of cartilage between the tympanic membrane or the tympanic membrane graft and the disk-shaped portion of the implant, and extrusions were never observed. Long-lasting inflammatory processes appeared to destroy implants the same way they destroy ossicles. Transient inflammatory periods (such as episodes of purulent otitis media, which occurred soon after the prostheses were implanted) did…
The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent…
2012
The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…
Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable dis…
2012
Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The si…
Narrow-diameter implants: A systematic review and meta-analysis.
2018
OBJECTIVES Narrow-diameter implants (NDI) are claimed to be a reasonable alternative to bone augmentation procedures. The aim of this comprehensive literature review was to conduct a meta-analysis comparing the implant survival of NDI and standard diameter implants (SDI) and to provide recommendations and guidelines for application of NDI. MATERIAL AND METHODS An extensive systematic literature search was performed in the PubMed/MEDLINE and the Cochrane Library databases. NDI were classified into Category 1 (implant diameter <3.0 mm, "mini-implants"), Category 2 (implant diameter 3-3.25 mm) and Category 3 (implant diameters 3.3-3.5 mm). Clinical studies at all levels of evidence with at lea…
Treatment concepts of horizontally deficient ridges-A retrospective study comparing narrow-diameter implants in pristine bone with standard-diameter …
2021
OBJECTIVES To compare clinical and radiological outcomes of narrow-diameter implants (NDI) placed in pristine bone to standard-diameter implants placed in combination with horizontal bone augmentation procedures (SDI+A) for horizontally deficient alveolar ridges. MATERIAL AND METHODS For this retrospective study, the outcome of 597 NDI (∅ 3.3 mm, 272 patients), inserted in pristine bone, were compared with 180 SDI (∅ 4.1 mm, 83 patients), inserted in combination with horizontal augmentation procedures. Oral health-related quality of life was assessed in patients available for recall. RESULTS After a mean follow-up of 37.6 ± 40 months for the NDI and of 42.4 ± 49 months for the SDI+A, surviv…
Effects of minute misregistrations of prefabricated markers for image-guided dental implant surgery: an analytical evaluation
2012
Objectives The goal of the present study was to develop a theoretical analysis of errors in implant position, which can occur owing to minute registration errors of a reference marker in a cone beam computed tomography volume when inserting an implant with a surgical stent. Material and methods A virtual dental-arch model was created using anatomic data derived from the literature. Basic trigonometry was used to compute effects of defined minute registration errors of only voxel size. The errors occurring at the implant's neck and apex both in horizontal as in vertical direction were computed for mean ±95%-confidence intervals of jaw width and length and typical implant lengths (8, 10 and 1…
Tooth-implant connection in removable denture.
2016
When the patient cannot be rehabilitated with a fixed denture, or when he does not succeed in adapting to a traditional removable denture, a possible alternative solution consists in the use of a limited number of implants, placed in strategic positions in the arches of the patient, and subsequently connected to their residual teeth. The aim of this review is to evaluate the progress made on connections between teeth and implants in removable denture, to analyze their advantages and disadvantages and to compare the survival rate, both of the teeth and of the implants used as abutments, present in the various studies taken into examination, with the aim of being able to evaluate the effectiv…
Topographic characterisation of dental implants for commercial use.
2016
Background To characterize the surface topography of several dental implants for commercial use. Material and Methods Dental implants analyzed were Certain (Biomet 3i), Tissue Level (Straumann), Interna (BTI), MG-InHex (MozoGrau), SPI (Alphabio) and Hikelt (Bioner). Surface topography was ascertained using a confocal microscope with white light. Roughness parameters obtained were: Ra, Rq, Rv, Rp, Rt, Rsk and Rku. The results were analysed using single-factor ANOVA and Student-Neuman-Keuls(p<0.05) tests. Results Certain and Hikelt obtained the highest Ra and Rq scores, followed by Tissue Level. Interna and SPI obtained lower scores, and MG-InHex obtained the lowest score. Rv scores followed …