Search results for "Prosthesis Design"

showing 10 items of 245 documents

A Prospective Noninterventional Study to Evaluate Survival and Success of Reduced Diameter Implants Made From Titanium-Zirconium Alloy

2015

Narrow diameter implants may be at increased risk of overload due to occlusal forces; therefore, implants with higher fatigue strength may be beneficial. The aim of this observational study was to evaluate survival and success of narrow diameter (Ø 3.3 mm) TiZr alloy (Roxolid, Institut Straumann AG, Basel, Switzerland) implants for 2 years in daily dental practice. This was a prospective, non-interventional, multicenter study; no specific patient inclusion or exclusion criteria were applied. Each patient received at least one TiZr implant; the treatment plan, including implant loading and final restoration, was at the investigator's discretion. The primary outcome was implant survival and s…

Dental ImplantsTitaniummedicine.medical_specialtybusiness.industryDental Implantation EndosseousCumulative survivalTitanium zirconiumSurgeryTreatment OutcomePrimary outcomeIncreased riskDental Prosthesis DesignMulticenter studyTreatment planAlloysHumansMedicineDental Restoration FailureProspective StudiesZirconiumImplant loadingImplantOral SurgerybusinessFollow-Up StudiesJournal of Oral Implantology
researchProduct

Impact of implant thread design on insertion torque and osseointegration:a preclinical model

2022

Successful osseointegration of endosteal dental implants has been attributed to implant design, including the macro-, micro- and nano- geometric properties. Based on current literature pertaining to implant design, the resultant cellular and bone healing response is unknown when the thread thickness of the implants is increased, resulting in an increased contact area in implants designed with healing chambers. The aim of this study was to evaluate the effect of two implant designs with different thread profiles on the osseointegration parameters and implant stability at 3- and 6-weeks in vivo using a well-established preclinical dog model. A total of 48 type V Ti alloy implants were divided…

Dental Implantsdoppler ultrasound imagingSurface PropertiesultrasoundDental Implantation Endosseousinfectionultrasound imagingDogsOtorhinolaryngologyTorqueDental Prosthesis DesignOsseointegrationAnimalsSurgeryGeneral DentistryUNESCO:CIENCIAS MÉDICAS
researchProduct

Meta-analysis on the survival of short implants

2010

Objective: To evaluate the success and failure rates of short implants (10 mm or less) for oral rehabilitations in cases of limited bone height. Study Design: Review of the articles published on the topic between the years 2000 and 2010, and development of a descriptive meta-analysis of the results. Results: The majority of the studies obtain a cumulative success rate (CSR) similar to that of longer implants (92.5% - 98.42% for machined and rough-surface implants, respectively). The studies that record lower cumulative success rates (CSR) are later studies that analyze implants with a machined surface. Almost none of the studi-es compared the success/failure rates with the bone quality or l…

Dental Implantsmedicine.medical_specialtybusiness.industryClinical study designDentistry:CIENCIAS MÉDICAS [UNESCO]SurgeryShort implantsMachined surfaceOtorhinolaryngologyDental Prosthesis DesignMeta-analysisMaxillaBone qualityUNESCO::CIENCIAS MÉDICASmedicineHumansSurgeryImplantDental Restoration FailureBone heightbusinessGeneral Dentistry
researchProduct

Influence of prefabricated post material on restored teeth: fracture strength and stress distribution.

2006

This work studied how prefabricated intraradicular post material affects the mechanical performance of restored teeth. The effect of using two different materials (glass fiber and stainless steel) with significantly different elastic moduli was studied.A combined theoretical and experimental method was used: first, an experimental fracture strength test was performed on 60 extracted human maxillary central incisors. The teeth were decoronated, treated endodontically and restored, 30 with glass fiber posts and 30 with stainless steel posts. The data were recorded and the results compared using an ANOVA test. Then, the finite element technique was used to develop a model of the restored tooth…

Dental Stress AnalysisMaterials scienceFinite Element AnalysisDentistryMaterials testingModels BiologicalStress (mechanics)Dental MaterialsTooth Fracturesstomatognathic systemFlexural strengthMaterials TestingDentinmedicineHumansComputer SimulationGeneral DentistryElastic modulusTooth Nonvitalbusiness.industryStress distributionElasticity (physics)Stainless SteelElasticityRoot Canal Therapymedicine.anatomical_structureDental Prosthesis DesignGlassStress MechanicalbusinessToothDental AlloysPost and Core TechniqueOperative dentistry
researchProduct

Influence of prefabricated post dimensions on restored maxillary central incisors

2007

summary  The aim of this study was to test the following hypothesis: biomechanical performance (fracture strength and stress distribution) of restored teeth is less sensitive to post diameter and post length when using glass fibre posts than when using stainless steel posts. First, an experimental fracture strength test was performed on 80 extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (40 with glass fibre posts and 40 with stainless steel posts), and the length and diameter of the posts varied uniformly. Failure loads were recorded and results were compared using an ancova analysis. Secondly, the finite element technique was used to …

Dental Stress AnalysisMaterials sciencebusiness.industryFinite Element AnalysisGlass fiberDentistryModels TheoreticalStress distributionStainless SteelModels DentalIncisorDental MaterialsDental Prosthesis DesignFlexural strengthMaterials TestingHumansComputer SimulationMaxillary central incisorDental Restoration FailureGlassFinite element techniquebusinessGeneral DentistryPost and Core TechniqueJournal of Oral Rehabilitation
researchProduct

Premolars restored with posts of different materials: fatigue analysis

2011

Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…

Dental Stress AnalysisMaterials sciencemedicine.medical_treatmentGlass fiberInfluence of post materialMaterials testingCrown (dentistry)Bite ForceDental MaterialsTooth FracturesFlexural strengthMaterials TestingmedicineHumansImplant denturesBicuspidComposite materialGeneral DentistryFEAFatigueTooth NonvitalCrownsImplants dentalsRestored teethStress distributionStainless SteelFinite element methodDental Prosthesis DesignDental Stress AnalysisCeramics and CompositesBiomechanical modelGlassDental materials--FatiguePrefabricated intraradicular postsMaterials dentals--FatigaDental AlloysPost and Core Technique
researchProduct

Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown.

2009

Summary  Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried ou…

Dental Stress Analysisinfluence of post-materialMaterials sciencemedicine.medical_treatmentGlass fiberFinite Element AnalysisDentistryCrown (dentistry)Dental Materialsstomatognathic systemFlexural strengthstress distributionMaterials TestingmedicineMaxillaHumansMaxillary central incisorDental Restoration PermanentGeneral Dentistryinfluence of post-diameterbusiness.industrybiomechanical performanceStress distributionIncisorstomatognathic diseasesDental Prosthesis DesignFracture (geology)pre-fabricated intra-radicular postsinfluence of crownFinite element techniqueGlassbusinessPost and Core TechniqueJournal of oral rehabilitation
researchProduct

A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: A minimally inva…

2020

Abstract The development of technologies that include face scanning and dental software has improved workflows in dentistry. Digital files make it possible to create a 3-dimensional virtual image of the patient that helps the clinician plan treatment and make decisions, reducing uncertainty and improving communication. This report describes the complete-mouth rehabilitation of a patient with severe tooth wear. The treatment adopted a minimal intervention approach, applying adhesive veneers in areas where the tooth structure was affected and used a computer-aided design and computer-aided manufacturing (CAD-CAM) workflow to prepare nanoceramic composite resin materials with a high filler loa…

Dental softwarebusiness.industryComputer scienceMouth RehabilitationIntervention approachDentistryCAD030206 dentistryComposite ResinsDental Porcelain03 medical and health sciences0302 clinical medicineDental porcelainstomatognathic systemDental Prosthesis DesignVirtual imageTooth wearDental Prosthesis DesignComputer-Aided DesignHumansTooth WearOral SurgeryMouth RehabilitationbusinessThe Journal of prosthetic dentistry
researchProduct

Contemporary practice and technical aspects in coronary intervention with bioresorbable scaffolds : a European perspective

2015

Aims Next to patient characteristics, the lack of a standardised approach for bioresorbable vascular scaffold (BVS) implantation is perceived as a potential explanation for the heterogeneous results reported so far. To provide some guidance, we sought to find a consensus on the best practices for BVS implantation and management across a broad array of patient and lesion scenarios. Methods and results Fourteen European centres with a high volume of BVS procedures combined their efforts in an informal collaboration. To get the most objective snapshot of different practices among the participating centres, a survey with 45 multiple choice questions was prepared and conducted. The results of th…

Diagnostic Imagingmedicine.medical_specialtyConsensusBest practiceMEDLINEPatient characteristicsConsensus criteriaCoronary Artery DiseaseProsthesis DesignPercutaneous Coronary InterventionPredictive Value of TestsRisk FactorsSurveys and QuestionnairesAbsorbable ImplantsmedicineHumansMedical physicsPractice Patterns Physicians'Multiple choiceBioresorbable vascular scaffoldbusiness.industryPatient SelectionSurgeryEuropeTreatment OutcomeHealth Care SurveysCardiology and Cardiovascular MedicinebusinessBioresorbable scaffoldIntravascular imagingHospitals High-Volume
researchProduct

Fractal-structured multifocal intraocular lens

2017

[EN] In this work, we present a new concept of IOL design inspired by the demonstrated properties of reduced chromatic aberration and extended depth of focus of Fractal zone plates. A detailed description of a proof of concept IOL is provided. The result was numerically characterized, and fabricated by lathe turning. The prototype was tested in vitro using dedicated optical system and software. The theoretical Point Spread Function along the optical axis, computed for several wavelengths, showed that for each wavelength, the IOL produces two main foci surrounded by numerous secondary foci that partially overlap each other for different wavelengths. The result is that both, the near focus an…

DiffractionOptical PhenomenaFocus (geometry)VisionSocial Scienceslcsh:MedicinePhysics::Optics01 natural sciences0302 clinical medicineMedicine and Health SciencesPsychologylcsh:ScienceLens (Anatomy)PhysicsMultidisciplinaryPhysicsOphthalmic ProceduresCataract SurgeryOptical LensesWavelengthFractalsOptical EquipmentPhysical SciencesEngineering and TechnologySensory PerceptionAnatomyDiffractionResearch ArticlePoint spread functionOcular AnatomyGeometryEquipmentSurgical and Invasive Medical ProceduresIn Vitro TechniquesProsthesis DesignProof of Concept Study010309 optics03 medical and health sciencesFractalOpticsOcular SystemOptical transfer function0103 physical sciencesChromatic aberrationPrototypesComputer Simulationbusiness.industrylcsh:RBiology and Life SciencesModels TheoreticalMultifocal Intraocular LensesOptical axisTechnology DevelopmentFISICA APLICADAWaves030221 ophthalmology & optometryEyeslcsh:QbusinessHeadMathematicsNeuroscience
researchProduct