Search results for "Prosthesis Design"

showing 10 items of 245 documents

Zirconia implant abutments: A review

2009

Objectives: An increasing aesthetic demand within developed populations conducted to the fabrication of metalfree restorations and to a wide use of ceramic materials, due to its excellent characteristics of biocompatibility and aesthetics. With the incessant increase of commercial labels involved in this technological advance, a review is imposed on ceramic abutments, specifically on zirconia. We made a search of articles of peer-reviewed Journals in PubMed/ Medline, crossing the terms ?Dental Abutments?, ?Dental Porcelain? and ?Zirconia?. The review was divided by subtopics: zirconia physical and mechanical properties, precision fit in the implant-abutment interface, zirconia abutments str…

Engineeringbusiness.industryProve itDentistryDental Abutments:CIENCIAS MÉDICAS [UNESCO]Ceramic abutmentsDental MaterialsDental porcelainDental Prosthesis DesignOtorhinolaryngologyDental AbutmentsUNESCO::CIENCIAS MÉDICASDental Prosthesis DesignHumansSurgeryCubic zirconiaZirconiumImplantTechnological advancebusinessGeneral DentistryMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Virtual simulation of an osseointegrated trans-humeral prosthesis: A falling scenario

2018

Abstract Introduction Traditional prosthetic solutions expose the amputee to numerous problems that limit his ability to safely perform the normal activities of daily life. In order to eliminate the problems related to the use of the traditional prosthesis with socket, a new technique was developed for fixing the prosthesis to the amputees based on the principle of osseointegration. The aim of this paper is to study and analyze the stress distribution on the interface between a trans-humeral osseointegrated prosthetic implant and the residual bone, identifying the most stressed areas and thus foreseeing possible failure phenomena of the entire prosthetic system and, after, to compare the st…

Finite element methodFinite Element Analysis0206 medical engineeringArtificial LimbsHumeru02 engineering and technologyThread (computing)FixtureProsthesis DesignOsseointegration prosthesis FE AnalysisOsseointegrationProsthesis Implantation03 medical and health sciencesAmputeeFinite Element Analysi0302 clinical medicineAmputeesOsseointegrationBone-Implant InterfaceHumansProsthesivon Mises yield criterionMedicineTorqueComputer SimulationOrthopedics and Sports MedicineForce platformUpper limbOsseointegration Prosthesis Amputees Upper limb Finite element methodSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeSimulationGeneral Environmental Science030222 orthopedicsbusiness.industryAccidental FallArtificial LimbHumerus020601 biomedical engineeringBiomechanical PhenomenaReactionEmergency MedicineBending momentGeneral Earth and Planetary SciencesAccidental FallsStress MechanicalbusinessHuman
researchProduct

Rehabilitation of the atrophic posterior maxilla with pterygoid implants: a review.

2012

The purpose of this article is to review the literature published and to assess the success of treatment of patients with atrophic posterior maxilla with pterygoid implants. Studies from 1992 to 2009 on patients with atrophic posterior maxilla rehabilitated with pterygoid implants were reviewed. Those reporting clinical series of at least 5 patients with atrophic posterior maxilla (Class IV and V of Cawood and Howell), rehabilitated with pterygoid implants and fixed prosthesis, and with 12 months minimum follow-up were included. In each study the following were assessed: number of patients, number of implants, surgical technique, prosthetic rehabilitation, success rate, bone loss, complica…

Fixed prosthesisProsthetic rehabilitationmedicine.medical_treatmentAlveolar Bone LossDentistryOutcome assessmentOral Surgical ProceduresPatient satisfactionstomatognathic systemOutcome Assessment Health CareSphenoid BonemedicineDental Prosthesis DesignMaxillaHumansOrthodonticsDental ImplantsRehabilitationbusiness.industryDental Implantation EndosseousMaxillary DiseasesDental Prosthesis DesignOral SurgerybusinessPosterior maxillaOral Surgical Procedures PreprostheticThe Journal of oral implantology
researchProduct

Vertical preparation for fixed prosthesis rehabilitation in the anterior sector

2015

This clinical report describes a biologically oriented preparation technique (BOPT) for teeth and an implant for the esthetic rehabilitation of the maxillary anterior sector. The technique was designed to create an anatomic crown with a prosthetic emergence profile that simulated the shape of the natural tooth.

Fixed prosthesismedicine.medical_treatmentDentistryEsthetics DentalCrown (dentistry)Clinical reportstomatognathic systemMaxillamedicineDental Prosthesis DesignHumansRehabilitationCrownsbusiness.industryDental prosthesisMiddle AgedTooth Preparation ProsthodonticDental Restoration Temporarystomatognathic diseasesDental Prosthesis DesignFemaleDental Prosthesis Implant-SupportedNatural toothImplantOral SurgerybusinessThe Journal of Prosthetic Dentistry
researchProduct

Ergebnisse nach Implantation von zementfreien metallspongiösen Hüftprothesen

1994

72 Huftgelenke mit zementfreier metallspongioser Huftprothese wurden zwei bis sieben Jahre (mittlere Nachuntersuchungszeit 43 Monate) nach der Implantation klinisch und rontgenologisch kontrolliert. Bei funf Patienten muste die zementfreie Prothese wegen Lockerung (ausbleibende knocherne Einheilung n=2, Pfannenlockerung infolge operationstechnischer Fehler n=3) gewechselt werden. Aufgrund der klinischen Befunde konnten 88% von 67 Huften mit sehr gut bzw. gut, 9% mit befriedigend und 3% mit unbefriedigend bewertet werden. 10% der Patienten klagten noch uber Oberschenkelschmerzen. Die typischen, rontgenologisch erkennbaren, knochernen Reaktionen des Implantatlagers werden beschrieben, eine In…

Gynecologymedicine.medical_specialtybusiness.industrymedicineFemur head necrosisFollow up studiesProsthesis designSurgerybusinessUnfallchirurgie
researchProduct

Immediate and flapless implant insertion and provisionalization using autogenous bone grafts in the esthetic zone: 5-year results.

2017

Objectives As the 2-year results for immediately inserted and provisionalized implants have been reported, it remained an open issue, whether the initially high success rates and the esthetic outcome remain stable for longer observation periods. Therefore, this prospective study examines the 5-year hard and soft tissue changes at implants placed in the anterior maxilla. Material and methods Meanwhile, 37 microthreaded implants were placed in 21 patients into extraction sockets with and without facial bone deficiencies by a flapless approach. Facial gaps and bony defects were grafted with autogenous bone chips. The implants were immediately provisionalized. The primary outcome parameters wer…

Immediate Dental Implant LoadingFacial bonemedicine.medical_treatmentAlveolar Bone LossDentistrySigns and symptomsEsthetics DentalTransplantation Autologous03 medical and health sciences0302 clinical medicineDental Implants Single-Tooth0502 economics and businessAlveolar ProcessMaxillaMedicineHumansDental Restoration FailureProspective StudiesAutogenous boneTooth SocketProspective cohort studyReduction (orthopedic surgery)Dental ImplantsBone TransplantationCrownsbusiness.industry05 social sciencesSoft tissue030206 dentistrySurvival RateTreatment OutcomeDental Prosthesis DesignCoronal planeTooth Extraction050211 marketingImplantZirconiumOral SurgerybusinessFollow-Up StudiesClinical oral implants research
researchProduct

Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: Pilot scan electron microscope and mechanical studies

2013

Objectives: Orthodontic mini-implants (OMIs) are increasingly used in orthodontics but can fail for various reasons. This study investigates the effects of OMI design characteristics on the mechanical properties in artificial bone. Material and Methods: Twelve self-drilling OMIs (2 small, 6 medium, 4 large) from 8 manufacturers were tested for their primary stability in simulated medium-high cancellous bone and the risk to fracture in high-density methacrylate blocks. For the assessments of the maximum insertion torque (IT) and torsional fracture (TF) 5 of each OMI were used and for the pull-out strength (POS) 10. The OMIs were inserted with a torque screwdriver (12 sec/360°) until the bott…

Insertion torqueDental Stress Analysisprimary stabilityArtificial boneMaterials scienceorthodontic mini-implantsTorsion MechanicalOdontologíatorsional fractureProsthesis Designpullout strengthDesign characteristicslaw.inventionMecànica de fracturalawRisk FactorsMaterials TestingBiomaterials and Bioengineering in DentistrymedicineOrthodontic Anchorage ProceduresFracture mechanicsGeneral Dentistry:Enginyeria dels materials::Desgast de materials [Àrees temàtiques de la UPC]Implants artificialsTorsion (mechanics)Implants ArtificialPullout strength:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludProsthesis Failuremedicine.anatomical_structureOtorhinolaryngologyMini implantsUNESCO::CIENCIAS MÉDICASMicroscopy Electron ScanningSurgeryResearch-ArticleElectron microscopeCancellous boneinsertion torqueBiomedical engineering
researchProduct

Effect of Decentration on the Optical Quality of Two Intraocular Lenses

2016

To analyze the effect of decentration on the optical quality of two diffractive-refractive intraocular lenses, a bifocal and a trifocal, when displaced laterally (horizontal direction) from the center.The AT LISA 809M IOL (+3.75 D add) with two main foci and the AT LISA tri 839MP intraocular lens with three main foci (Carl Zeiss Meditec AG, Jena, Germany) were analyzed. The optical quality of the intraocular lenses was measured with the PMTF (power and modulation transfer function [MTF] measurement for refractive and diffractive intraocular lenses) optical bench (Lambda-X, Nivelles, Belgium). The optical quality of the lenses was evaluated by the MTF at different object vergences, the avera…

Lenses IntraocularOptics and Photonicsbusiness.industryVision TestsProsthesis DesignRefraction OcularRefractionOptical quality03 medical and health sciencesOphthalmologyOcular physiology0302 clinical medicineOpticsIntraocular lenses030221 ophthalmology & optometryHumansProsthesis designOptometryVision testbusinessVision Ocular030217 neurology & neurosurgeryGeologyOptometryOptometry and Vision Science
researchProduct

Impact of contact lens material and design on the ocular surface.

2018

BACKGROUND: To evaluate the impact on the ocular surface of a daily disposable hydrogel contact lens with high water content compared with two silicone hydrogel daily disposable lenses of lower water content. METHODS: The hydrogel lens assessed was made from nesofilcon A and the silicone hydrogel lenses were made of delefilcon A and stenfilcon A. Contact lens thickness was measured to assess material stability during daily wear, and ocular surface parameters such as tear film osmolarity, tear meniscus area and central corneal thickness were also assessed. Optical quality was analysed for all cases by means of wavefront aberrometry. RESULTS: The nesofilcon A was shown to be the thinnest lens…

Lentes de contacto desechablesAdultMaleContact lens materialMaterials sciencegenetic structuresSurface PropertiesProsthesis Designcomplex mixturesHydrogel Polyethylene Glycol Dimethacrylatelaw.inventionCornea03 medical and health sciencesYoung Adult0302 clinical medicineCorneal edemalawMyopiaHumansDisposable EquipmentOsmolar Concentrationtechnology industry and agricultureEquipment DesignDaily wearContact Lenses HydrophilicColoideseye diseasesContact lensLens (optics)OphthalmologyTear meniscusTears030221 ophthalmology & optometryOftalmologíaDaily disposableFemalesense organsOcular surfaceConjunctiva030217 neurology & neurosurgeryOptometryBiomedical engineeringClinicalexperimental optometry
researchProduct

Contrast sensitivity and color perception with orange and yellow intraocular lenses

2012

To evaluate contrast sensitivity function (CSF) and color vision after implantation of either orange or yellow-tinted intraocular lenses (IOLs).Fifty-six eyes of 28 cataract patients who had bilateral implantation of orange-tinted (PC440Y Orange, Ophtec), yellow-tinted (AcrySof Natural SN60AT, Alcon), or clear (AcrySof SA60AT, Alcon) IOLs were examined. Six months postoperatively, monocular CSF under photopic and mesopic (with and without glare) conditions were measured using the Functional Visual Analyzer. Color discrimination was determined with the Farnsworth-Munsell 100-Hue test.Patients implanted with orange-tinted, yellow-tinted, or clear IOLs displayed similar CSF values, with no sta…

Male0301 basic medicinemedicine.medical_specialtygenetic structuresColor visionmedicine.medical_treatmentMesopic VisionVisual AcuityOrange (colour)Prosthesis DesignColor discriminationContrast Sensitivity03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOphthalmologyHumansMedicineProsthesis designProspective StudiesAgedLenses IntraocularPhacoemulsificationColor Visionbusiness.industryGeneral MedicinePhacoemulsificationeye diseasesOphthalmology030104 developmental biologyIntraocular lenses030221 ophthalmology & optometryFemalesense organsbusinessColor PerceptionEuropean Journal of Ophthalmology
researchProduct