Regurgitant flow in apparently normal valve prostheses: improved detection and semiquantitative analysis by transesophageal two-dimensional color-cod…

1990

In 128 patients with apparently normally functioning prosthetic valves ( n = 136) in the aortic position ( n = 79) and the mitral position ( n = 57), the prevalence of transprosthetic regurgitant flow was studied by use of transthoracic and transesophageal two-dimensional color-coded Doppler echocardiography. With the transthoracic approach, regurgitant flow was detected in early systole or diastole for 28% of the mitral prostheses and for 29% of the aortic prostheses. With transesophageal color-coded Doppler echocardiography, regurgitant jets were visualized for 95% of the mitral prostheses and for 44% of the aortic prostheses. In 40% of the Bjork-Shiley prostheses and 88% of the St. Jude …

Aortic valveAdultMalemedicine.medical_specialtyAdolescentAortic Valve InsufficiencyDiastoleDoppler echocardiographyInternal medicineMitral valvemedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesSystoleTransthoracic approachAgedmedicine.diagnostic_testbusiness.industryMiddle Agedequipment and suppliesEchocardiography DopplerRegurgitant flowProsthesis Failuremedicine.anatomical_structureAortic ValveHeart Valve Prosthesiscardiovascular systemCardiologyMitral ValveFemaleCardiology and Cardiovascular MedicinebusinessSemi quantitativecirculatory and respiratory physiologyJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
researchProduct

Juxtapapillary duodenal diverticular bezor as an exceptional cause of biliary stent obstruction. Case report.

2007

INTRODUCTION: we describe the first case in literature of biliary stent obstruction by bezoar impaction in a iuxtapapillary duodenal diverticulum. CASE REPORT: this case illustrates an juxtapapillary duodenal diverticulum and bezoar in it causing obstructive jaundice in subject with two biliary stents for cholangiocarcinoma (Klatskin's tumor) in the absence of bile duct stones. RESULT: successful treatment with endoscopic stent removal and diverticulum toilette. Obstructive jaundice was cured after endoscopic removal of the bezoar and stent substitution. DISCUSSION: the presence of a bezoar and its possible contribution to the pathogenesis of pancreatitis in the presence of periampullary ex…

BezoarsMaleDiverticulumJaundice ObstructiveHumansStentsDuodenal Diseasesaged bezoar diverticulosis duodenum disease obstructive jaundice prosthesis failure stentAgedProsthesis FailureIl Giornale di chirurgia
researchProduct

Thrombosis, fracture, and percutaneous removal of a patent foramen ovale closure device 1 month after successful deployment

2010

Several different devices have been developed for the percutaneous closure of interatrial defects and patent foramen ovale. Although the implantation of these devices is both safe and effective, a number of complications, both in the early and the late follow-up, may occur. We describe a case of device fracture manifested early (1 month after implantation) with the formation of massive thrombosis on the right atrial disc. The patient was treated with anticoagulants and the device was percutaneously retrieved. Our images allowed early noninvasive therapy and emphasize the need for echocardiographic follow-up early after implantation. © 2010 Wiley-Liss, Inc.

Cardiac Catheterizationmedicine.medical_specialtyTime FactorsPercutaneousSeptal Occluder DeviceForamen Ovale PatentProsthesis DesignRight atrialmedicineHumansRadiology Nuclear Medicine and imagingDevice Removalbusiness.industryAnticoagulantsThrombosisGeneral MedicineMiddle Agedmedicine.diseaseThrombosisProsthesis FailureSurgeryRadiographyTreatment OutcomePatent foramen ovaleFemaleCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealCatheterization and Cardiovascular Interventions
researchProduct

Etiology, risk factors and management of implant fractures.

2009

Implant fracture is an infrequent and late biomechanical complication with a serious clinical outcome. In effect, such fractures pose important problems for both the patient and the dental surgeon. According to most literature sources, the prevalence of dental implant fractures is very low (approximately 2 fractures per 1000 implants in the mouth). Considering that implant placement is becoming increasingly popular, an increase in the number of failures due to late fractures is to be expected. Clearly, careful treatment can contribute to reduce the incidence of fracture. An early diagnosis of the signs alerting to implant fatigue, such as loosening, torsion or fracture of the post screws an…

Dental Implantsmedicine.medical_specialtybusiness.industrymedicine.medical_treatmentDentistry:CIENCIAS MÉDICAS [UNESCO]SurgeryProsthesis FailureImplant placementOtorhinolaryngologyRisk FactorsUNESCO::CIENCIAS MÉDICASmedicineEtiologymedia_common.cataloged_instanceHumansSurgeryImplantbusinessDental implantGeneral DentistryDental surgeonmedia_commonMedicina oral, patologia oral y cirugia bucal
researchProduct

Endovascular stentectomy using the snare over stent-retriever (SOS) technique: An experimental feasibility study

2017

PLoS one 12(5), e0178197 (2017). doi:10.1371/journal.pone.0178197

GlycerolSwinePhysiologylcsh:Medicine030218 nuclear medicine & medical imaging0302 clinical medicinePig ModelsBlood FlowMedicine and Health SciencesMedicinelcsh:ScienceData flow modelClinical scenarioMammalsMultidisciplinaryExperimental DesignEndovascular ProceduresVasospasmAnimal ModelsProsthesis FailureBody FluidsPhysical sciencesChemistryBloodExperimental Organism SystemsResearch DesignVertebratesFemaleStentsRadiologyAnatomyResearch ArticleBiotechnologymedicine.medical_specialtyCathetersSurgical and Invasive Medical ProceduresMonomers (Chemistry)Research and Analysis Methods03 medical and health sciencesAnimal modelText miningIn vivoBlood vessel prosthesisAnimalsHumansPolymer chemistryStent retrieverbusiness.industrylcsh:ROrganismsBiology and Life Sciencesmedicine.diseaseBlood Vessel ProsthesisDisease Models AnimalStent ImplantationAmniotesFeasibility StudiesMedical Devices and Equipmentlcsh:Qbusiness030217 neurology & neurosurgeryPLOS ONE
researchProduct

Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: Pilot scan electron microscope and mechanical studies

2013

Objectives: Orthodontic mini-implants (OMIs) are increasingly used in orthodontics but can fail for various reasons. This study investigates the effects of OMI design characteristics on the mechanical properties in artificial bone. Material and Methods: Twelve self-drilling OMIs (2 small, 6 medium, 4 large) from 8 manufacturers were tested for their primary stability in simulated medium-high cancellous bone and the risk to fracture in high-density methacrylate blocks. For the assessments of the maximum insertion torque (IT) and torsional fracture (TF) 5 of each OMI were used and for the pull-out strength (POS) 10. The OMIs were inserted with a torque screwdriver (12 sec/360°) until the bott…

Insertion torqueDental Stress Analysisprimary stabilityArtificial boneMaterials scienceorthodontic mini-implantsTorsion MechanicalOdontologíatorsional fractureProsthesis Designpullout strengthDesign characteristicslaw.inventionMecànica de fracturalawRisk FactorsMaterials TestingBiomaterials and Bioengineering in DentistrymedicineOrthodontic Anchorage ProceduresFracture mechanicsGeneral Dentistry:Enginyeria dels materials::Desgast de materials [Àrees temàtiques de la UPC]Implants artificialsTorsion (mechanics)Implants ArtificialPullout strength:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludProsthesis Failuremedicine.anatomical_structureOtorhinolaryngologyMini implantsUNESCO::CIENCIAS MÉDICASMicroscopy Electron ScanningSurgeryResearch-ArticleElectron microscopeCancellous boneinsertion torqueBiomedical engineering
researchProduct

Volar Fixed-Angle Plating of Distal Radius Fractures

2011

The purpose of this biomechanical study was to determine whether a multidirectional fixed-angle plate with locking screws or with locking pegs in the distal fragment would optimize fixation of Orthopaedic Trauma Association (OTA) type A3 distal radius fractures.Eight pairs of fresh-frozen human distal radii were used. Extra-articular distal radius fractures were created and stabilized with a multidirectional volar fixed-angle plate. The radii were randomized into 2 matched-paired groups. The distal fragment in Group I was stabilized with 7 locking screws. The distal fragment in Group II was fixed with 7 locking pegs. The proximal fragment in both groups was fixed with 3 screws. The specimen…

MaleBone ScrewsBone NailsBiomechanical PhenomenaFracture Fixation InternalFixation (surgical)Fixed angleCadaverFracture fixationBone plateCadaverHumansMedicineOrthopedics and Sports MedicineAgedMechanical PhenomenaAged 80 and overOrthodonticsbusiness.industryGeneral MedicineRadiusMiddle AgedBiomechanical PhenomenaProsthesis FailureEquipment Failure AnalysisFemaleSurgeryRadius FracturesbusinessCadaveric spasmBone PlatesJournal of Orthopaedic Trauma
researchProduct

Complications in Craniovertebral Junction Instrumentation: Hardware Removal Can Be Associated with Long-Lasting Stability. Personal Experience

2017

Background The causes of craniovertebral junction (CVJ) instabilities include trauma, rheumatological diseases, tumors, infections, congenital malformations, and degenerative disease processes; these complex pathologies often require CVJ instrumentation. Hardware complications were analyzed in a personal series of 48 treated patients. In light of the analysis of very unusual radiological and clinical findings, the authors tried to better investigate the related mechanisms and to reach possible useful conclusions. Methods In a series of 48 patients who underwent CVJ instrumentation and fusion procedures in our Institution, we describe three cases of hardware failure, due to: (1) infection; (…

MaleBone ScrewsOccipito-cervical fusionOccipito cervical fusion030218 nuclear medicine & medical imagingPostoperative Complications0302 clinical medicineDegenerative diseaseMedicineAxis Cervical VertebraBone infections; Craniovertebral junction; Occipito-cervical fusion; Screwing; Wiring; Surgery; Neurology (clinical)EncephaloceleMedulla OblongataWiringSettore MED/27 - NeurochirurgiaCraniovertebral junctionCongenital malformationsMiddle AgedDecompression SurgicalMagnetic Resonance ImagingBone infectionsProsthesis FailureAtlanto-Axial JointRadiological weaponScrewingComputer hardwareBone WiresJoint InstabilityLong lastingProsthesis-Related InfectionsAdolescentAntineoplastic AgentsBone NeoplasmsCongenital Abnormalities03 medical and health sciencesOdontoid ProcessHumansInstrumentation (computer programming)Device RemovalRadiotherapybusiness.industrymedicine.diseaseRadiographyAtlanto-Occipital JointSpinal FusionSurgeryNeurology (clinical)Tomography X-Ray Computedbusiness030217 neurology & neurosurgeryPlasmacytoma
researchProduct

New aspects in the histological examination of polyethylene wear particles in failed total joint replacements.

2002

The most important long-term complication in total joint replacements is aseptic osteolysis. Wear particles such as polyethylene (PE) debris are considered to be one of the causes that play a central role. Several studies indicated that PE can be visualised in paraffin-embedded tissue sections not only by polarised light, but also after oil red staining. To determine whether oil red staining enables sensitive detection of PE, we examined staining of mechanically-produced PE particles by oil red. Furthermore, we studied oil red staining of paraffin-embedded tissue specimens of patients with failed uncemented and cemented total knee and hip prostheses. We applied double labelling of sections …

MalePathologymedicine.medical_specialtyHistologyOsteolysisLightJoint ProsthesisTotal Joint ReplacementsAntigens Differentiation MyelomonocyticStainArthroplasty03 medical and health scienceschemistry.chemical_compound0302 clinical medicineAntigens CDMaterials TestingmedicineHumansColoring AgentsHistological examination030222 orthopedicsChemistryCell BiologyGeneral MedicineProstheses and ImplantsPolyethylenemedicine.diseaseImmunohistochemistry3. Good healthSurgeryStainingProsthesis FailureMicroscopy Electron030220 oncology & carcinogenesisImmunohistochemistryFemaleJointsAseptic processingPolyethylenesAzo CompoundsActa histochemica
researchProduct

The Use of Computer Navigation in Total Hip Arthroplasty Is Associated with a Reduced Rate of Revision for Dislocation

2021

BACKGROUND: The use of computer navigation has been shown to produce more accurate cup positioning when compared with non-navigated total hip arthroplasty (THA), but so far there is only limited evidence to show its effect on clinical outcomes. The present study analyzed data from the Australian Orthopaedic Association National Joint Replacement Registry to assess the impact of computer navigation on the rates of all-cause revision and revision for dislocation following THA. METHODS: Data for all non-navigated and navigated primary THAs performed for osteoarthritis in Australia from January 1, 2009, to December 31, 2019, were examined to assess the rate of revision. We analyzed the effects …

MaleReoperationmedicine.medical_specialtyArthroplasty Replacement HipOsteoarthritisProsthesis DesignOsteoarthritis Hip03 medical and health sciencesPostoperative Complications0302 clinical medicineHip DislocationHumansMedicineOrthopedics and Sports MedicineComputer navigationRegistriesAged030222 orthopedicsbusiness.industryHazard ratioGeneral MedicineMiddle Agedmedicine.diseaseConfidence intervalProsthesis FailureSurgerySurgery Computer-AssistedJoint replacement registry030220 oncology & carcinogenesisOrthopedic surgeryCohortFemaleSurgerybusinessTotal hip arthroplastyJournal of Bone and Joint Surgery
researchProduct