Search results for "Prosthesis Fitting"

showing 9 items of 19 documents

Locking Reconstruction Double Plating of Distal Humeral Fractures: How Many Screws in the Distal Ulnar Column Segment in A3 Fracture Provide Superior…

2009

Objectives: Two 90-degree configurations of locking reconstruction plates with different numbers of screws in the distal ulnar column segment of distal extra-articular humeral fractures with metaphyseal comminution (A3) were biomechanically investigated. Methods: Eight pairs of fresh-frozen human humeri were used. For paired comparison, the humeri were divided into 2 randomized groups. In both groups, double-plate osteosyntheses with locking reconstruction plates were performed in 90-degree configurations. In group 1, the posteriorly placed radial column plate exceeded the capitellum and the ulnar column plate extended into the ulnar sulcus. The ulnar plate was molded around the medial epic…

Joint InstabilityMalemusculoskeletal diseasesHumeral Fracturesmedicine.medical_specialtyCompressive StrengthBone ScrewsUlnaBendingWeight-BearingElastic ModulusProsthesis FittingTensile StrengthElbow JointmedicineHumansOrthopedics and Sports MedicineHumerusAged 80 and overOrthodonticsOsteosynthesisbusiness.industryBiomechanicsStiffnessGeneral MedicineMiddle Agedmusculoskeletal systemSurgeryTreatment Outcomemedicine.anatomical_structureFracture (geology)FemaleSurgeryImplantmedicine.symptomElbow InjuriesEpicondylebusinessBone PlatesJournal of Orthopaedic Trauma
researchProduct

Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management

2019

Purpose: To evaluate the visual quality results when fitting a corneo-scleral contact lens (CScL) after intracorneal ring segment (ICRS) implantation for keratoconus management. Methods: Twenty-seven eyes of 27 patients with keratoconus underwent ICRS implantation and had CScL fitted as their visual quality was unsatisfactory with their spectacles or contact lenses. Patients received a complete eye examination, refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count, and visual quality assessment using contrast sensitivity and aberrometry tests. A diagnostic trial set was used in the fitting process…

MaleCorneal Wavefront AberrationVisual acuitygenetic structuresVisual Acuity0302 clinical medicineIntracorneal ring segmentProsthesis FittingContrast (vision)media_commonmedicine.diagnostic_testQuality assessmentCorneoscleral contact lensProstheses and ImplantsGeneral MedicineMiddle AgedRefractive ErrorsEye examinationFemalemedicine.symptomScleraAdultmedicine.medical_specialtyKeratoconusCorneal ectasiaContact LensesCorneal Stromamedia_common.quotation_subjectKeratoconusContrast SensitivityProsthesis ImplantationYoung Adult03 medical and health sciencesOphthalmologyAberrometrymedicineHumansIntracorneal ring segmentbusiness.industryAberrometryCorneal Topographymedicine.diseaseeye diseasesContact lensOphthalmology030221 ophthalmology & optometrysense organsbusiness030217 neurology & neurosurgeryOptometryContact Lens and Anterior Eye
researchProduct

Preserving the abductor mechanism in robotic THR: the influence of stem design and cutterpath.

2004

The tip of the greater trochanter is the attachment site for the abductor muscles of the hip joint. Its preservation in robotic and conventional THR is important for normal gait. The effect of different stem designs and robotic cutterpaths on the preservation of the trochanter tip is examined.One anatomical stem, one straight stem, and one stem specifically designed for robotic THR were implanted virtually in CT scans of osteoarthrotic hip joints using the Torch preoperative planning unit (URS-ortho). In transverse sections of the trochanter tip, dimensions of the trochanter area removed by the milling tool were recorded for each stem design and different cutterpaths (3-axis versus 5-axis m…

MaleGreater trochanterMaterials scienceAttachment siteArthroplasty Replacement HipUser-Computer InterfaceProsthesis FittingOsteoarthritismedicineHumansFemurMuscle SkeletalGaitPreoperative planningTrochantertechnology industry and agricultureStraight stemAnatomyRoboticsComputer Science ApplicationsMechanism (engineering)Normal gaitmedicine.anatomical_structureSurgery Computer-AssistedSurgeryMuscles of the hipFemaleHip JointFamily PracticeTomography X-Ray ComputedBiomedical engineeringComputer aided surgery : official journal of the International Society for Computer Aided Surgery
researchProduct

Fitting Scleral Lenses Less Than 15 mm in Diameter: A Review of the Literature.

2020

OBJECTIVE To perform a comprehensive review of the current and historical scientific literature on fitting small scleral lenses (diameter <15 mm) and clarifying their advantages and disadvantages, in addition to their clinical applications. METHODS The literature search was performed through PubMed from MEDLINE. RESULTS Eleven studies of case series (258 eyes) were found. Indications were similar to those of larger scleral lenses, 74% for corneal irregularities (mainly keratoconus), whereas 26% for ocular surface diseases. In the studies on cases of irregular corneas, visual acuity improved significantly regarding the values before and after fitting the lenses (mean, 0.4-0.03 logMar, respec…

MaleKeratoconusmedicine.medical_specialtyVisual acuitygenetic structuresContact LensesProsthesis Designlaw.inventionCorneal Diseases03 medical and health sciences0302 clinical medicineScleral lenslawOphthalmologyProsthesis FittingmedicineHumansbusiness.industryDaily wearmedicine.diseaseeye diseasesLens (optics)Ophthalmology030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessOcular surface030217 neurology & neurosurgeryScleraEyecontact lens
researchProduct

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.

2014

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectLentes de contatoVisual AcuityPupilContrast Sensitivitylcsh:OphthalmologymedicineContrast (vision)HumansContact lensesPresbyopia/rehabilitationPupilaPresbiopia/reabilitaçãomedia_commonMathematicsCross-Over StudiesColor VisionPupilGeneral MedicinePresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseContact Lenses HydrophilicAjuste de próteseeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment Outcomelcsh:RE1-994Dominância ocularOptometryFemalemedicine.symptomProsthesis fitting dominance ocularPhotopic visionArquivos brasileiros de oftalmologia
researchProduct

Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism

2017

Purpose: To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. Methods: A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period wa…

Malemedicine.medical_specialtyKeratoconusCorneal Wavefront AberrationVisual acuityCorneal ectasiagenetic structuresContact LensesVisual AcuityAstigmatismKeratoconusCornea03 medical and health sciences0302 clinical medicineProsthesis FittingOphthalmologyCorneamedicineHumansHigh orderIrregular astigmatismmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyEye Diseases HereditaryCorneoscleral contact lensGeneral MedicineMiddle Agedmedicine.diseaseCorneal topographyeye diseasesOphthalmologyHyperopiamedicine.anatomical_structureEye examination030221 ophthalmology & optometrysense organsmedicine.symptombusinessSclera030217 neurology & neurosurgeryOptometry
researchProduct

Reliability and validity of the Finnish version of the prosthesis evaluation questionnaire

2018

Background: Thus far there have been no specific patient-reported outcome instrument in Finnish for health-related quality of life (HRQoL) assessment after major lower extremity amputation and successful prosthesis fitting. Methods: The prosthesis evaluation questionnaire (PEQ) was translated and cross-culturally adapted into Finnish. Participants completed a questionnaire package including the Finnish version of the PEQ and the 15 D HRQoL instrument. Scales (n = 10) were tested for internal consistency, floor-ceiling effect, and reproducibility for which participants completed the PEQ twice within a 2-week interval. Validity was tested by estimating the correlation between the 15 D index a…

Malepsychometrics030506 rehabilitationvalidityPsychometricsmedicine.medical_treatmentelämänlaatupatientsProsthesisDISEASEpotilaat0302 clinical medicineQuality of lifeQUALITY-OF-LIFEProsthesis FittingSurveys and QuestionnairesInternal consistencyHrqol instrumentFinlandReliability (statistics)ta316terveydenhuoltoRehabilitationPAINta3141healthMiddle Agedquestionnaire surveyreliability (general)3142 Public health care science environmental and occupational healthLower ExtremityFemale0305 other medical sciencePsychologyAdultmedicine.medical_specialtykyselytutkimusAmputation SurgicalVALIDATIONLOWER-LIMB AMPUTATIONS03 medical and health sciencesAmputeesCronbach's alphaamputationSuomimedicineHumansTranslationsPatient Reported Outcome MeasuresAgedproteesitreliabilityamputaatioReproducibility of Results3126 Surgery anesthesiology intensive care radiologyquality of lifeAmputationUTILITY INSTRUMENTSPhysical therapySCALESprosthesis030217 neurology & neurosurgery
researchProduct

Postoperative Lens Position Preoperatively Determined by Scheimpflug Photography

1999

The position of the artificial lens has an important influence on refractive power calculation. We compared the position of the crystalline lens with that of the artificial lens after cataract surgery by means of Scheimpflug photography. A difference in position of approximately 0.8 mm in the anterior direction could be determined.

medicine.medical_specialtygenetic structuresComputer Science::Neural and Evolutionary ComputationScheimpflug principlePhysics::OpticsAfter cataractOptical powerCataract ExtractionAstrophysics::Cosmology and Extragalactic Astrophysicslaw.inventionCataract extractionCellular and Molecular NeuroscienceLens Implantation IntraocularPosition (vector)lawProsthesis FittingOphthalmologyLens CrystallinePreoperative Caremental disordersPhotographymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryPhotographyGeneral Medicineeye diseasesSensory SystemsLens (optics)OphthalmologyOptometrysense organsbusinesspsychological phenomena and processesOphthalmic Research
researchProduct

Lens implant selection with absence of capsular support.

2001

If contact lens or spectacle correction is not viable, little debate exists that the secondary placement of an intra-ocular lens (IOL) is the method of choice in the absence of capsular support. The choice of IOL mainly depends on the preoperative status of the eye (eg, aphakia in children) and the selected location for the implant. Theoretically, there are several IOL implantation approaches in cases without capsular support: an angle-supported anterior chamber (AC) IOL, an iris-fixated ACIOL, an iris-sutured or iris-fixated posterior chamber (PC) IOL and a transsclerally sutured PCIOL. No consensus exists, however, on the indications as well as on the relative safety and efficacy of these…

medicine.medical_specialtygenetic structuresLens Capsule CrystallineGlaucomaProsthesis DesignAphakiaLens Implantation IntraocularAnterior Eye SegmentCorneaOphthalmologyProsthesis FittingMedicineHumansLenses Intraocularbusiness.industrySuture TechniquesGeneral Medicinemedicine.diseaseeye diseasesAnterior Eye SegmentContact lensOphthalmologymedicine.anatomical_structureAniridiasense organsImplantbusinessShallow anterior chamberCurrent opinion in ophthalmology
researchProduct