Effect of Polarity Reversal on the Partial Discharge Phenomena

2020

In the field of High Voltage Direct Current (HVDC) transmission, the space charge accumulation phenomenon and the Partial Discharges (PD) phenomena are considered the main causes of dielectric ageing. During the years, the degradation effect of both phenomena under constant DC stress has been widely studied by several researchers. In case of polarity reversal, typically carried out to control bi-directional power flow between interconnected High Voltage transmission systems, the space charge movement may not synchronously follow the electric field polarity. This could make the moment of reversing polarity a very critical one, where space charge injected during preceding polarity produces hi…

010302 applied physicsPolarity reversalMaterials scienceHVDCPolarity (physics)polarity reversalHigh voltage02 engineering and technologyMechanicsDielectric021001 nanoscience & nanotechnology01 natural sciencesSpace chargeElectric fieldPartial discharge0103 physical sciencesPartial dischargePryCamHigh-voltage direct current0210 nano-technologyAir void
researchProduct