Search results for "Pupil"

showing 10 items of 181 documents

Pharmacologic pupil dilation as a predictive test for the risk for intraoperative floppy-iris syndrome.

2011

PURPOSE: To evaluate the effect of α1-adrenergic receptor antagonists (α1-ARAs) on pupil diameter and determine whether the diameter predicts intraoperative floppy-iris syndrome (IFIS). SETTING: Ophthalmology Section, Palermo University, Palermo, Italy. DESIGN: Prospective cohort study. METHODS: Male outpatients taking tamsulosin, α(1)-ARAs, or no α(1)-ARAs having phacoemulsification were recruited. Pupils were measured 1 month preoperatively, immediately preoperatively, and postoperatively under mesopic low (0.4 lux) and high (4.0 lux) illumination after pharmacologic dilation. The IFIS severity was graded. RESULTS: Each group comprised 50 patients. Pharmacologic dilation in both α(1)-ARA …

MaleTamsulosinmedicine.medical_specialtyMydriaticsmedicine.medical_treatmentIntraoperative floppy iris syndromeSensitivity and SpecificityPupilCohort StudiesPhenylephrineTropicamideTamsulosinPredictive Value of TestsRisk FactorsmedicinePupillary responseHumansProspective StudiesProspective cohort studyIntraoperative ComplicationsAgedSulfonamidesPhacoemulsificationbusiness.industrySettore MED/30 - Malattie Apparato VisivoDoxazosinfood and beveragesMuscle SmoothPupilPhacoemulsificationPrazosinSyndromebiochemical phenomena metabolism and nutritionmedicine.diseaseSensory SystemsSurgerycarbohydrates (lipids)OphthalmologyDrug CombinationsIfis pupil dilation tamsulosinIris DiseasesPredictive value of testsAdrenergic alpha-1 Receptor AntagonistsSurgerybusinessCohort studymedicine.drugJournal of cataract and refractive surgery
researchProduct

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.

2014

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectLentes de contatoVisual AcuityPupilContrast Sensitivitylcsh:OphthalmologymedicineContrast (vision)HumansContact lensesPresbyopia/rehabilitationPupilaPresbiopia/reabilitaçãomedia_commonMathematicsCross-Over StudiesColor VisionPupilGeneral MedicinePresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseContact Lenses HydrophilicAjuste de próteseeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment Outcomelcsh:RE1-994Dominância ocularOptometryFemalemedicine.symptomProsthesis fitting dominance ocularPhotopic visionArquivos brasileiros de oftalmologia
researchProduct

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens

2007

To determine whether pupil size is correlated with visual acuity and contrast sensitivity at all distances in eyes with an apodized diffractive intraocular lens (IOL).Private Clinic, Oviedo, Spain.Six months after surgery, the best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were measured in 670 eyes of 335 consecutive patients who had implantation of the AcrySof ReSTOR Natural IOL (SN60D3, Alcon). Pupil diameters in distance vision were measured using a pupillometer.The logMAR best corrected distance acuity was significantly better with …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityCorrelationLens Implantation IntraocularHumansMedicineContrast (vision)Prospective Studiesmedia_commonLenses Intraocularbusiness.industryPupilMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerysense organsSpatial frequencymedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Perioperative pupil size in low-energy femtosecond laser-assisted cataract surgery

2020

Purpose To assess potential changes in pupil size during femtosecond laser-assisted cataract surgery (FLACS) using a low-energy laser system. Methods The pupil sizes of eyes undergoing FLACS were measured using the Ziemer LDV Z8 by extracting images from the laser software after each of the following steps: application of suction, lens fragmentation, and capsulotomy. Furthermore, the pupil diameters were measured based on preoperative surgical microscope images and after releasing the suction. Paired t-test and the two one-sided tests (TOST) procedure were used for statistical analyses. The horizontal and vertical pupil diameters were compared in each of the steps with preoperative values.…

Malegenetic structuresProstaglandinmedicine.medical_treatmentBiochemistryPupillaw.inventionCornea0302 clinical medicinelawCorneaMedicine and Health SciencesLipid HormonesAged 80 and overEye LensMultidisciplinaryQOphthalmic ProceduresRCataract SurgeryMiddle Agedmedicine.anatomical_structureOptical EquipmentCapsulotomyEngineering and TechnologyMedicineFemaleLaser TherapyAnatomyResearch Articlemedicine.medical_specialtySuctionOcular AnatomyScienceEquipmentSurgical and Invasive Medical ProceduresCataract Extraction03 medical and health sciencesOcular SystemOphthalmologymedicineHumansPerioperative PeriodAgedRetrospective Studiesbusiness.industryLasersBiology and Life SciencesPupilPerioperativeCataract surgeryLaserHormoneseye diseasesConfidence interval030221 ophthalmology & optometryEyessense organsbusinessHead030217 neurology & neurosurgeryPLOS ONE
researchProduct

Optical quality after instillation of eyedrops in dry-eye syndrome

2010

Purpose To study the effect of eyedrop instillation on the optical quality of the air–tear film interface at the anterior cornea in cases of dry eye. Setting University of Valencia, Valencia, Spain. Methods Corneal aberrations (total, spherical-like, and coma-like) were determined from corneal elevation maps and purpose-designed software in cases of dry eye before, immediately after, and 10 minutes after lubricating eyedrop instillation (Blink Intensive Tears). All data were decomposed using Zernike polynomials to yield the root-mean-square wavefront deviations for pupil diameters of 3.0 mm and 5.5 mm. Outcome measures included comparison with clinical tear breakup time (TBUT). Results Wave…

Malemedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersDry Eye SyndromesPupilCorneaCorneaOphthalmologymedicineHumansmedicine.diagnostic_testbusiness.industryAirCorneal TopographyMiddle Agedmedicine.diseaseCorneal topographyeye diseasesSensory SystemsOptical qualityOphthalmologyArtificial tearsmedicine.anatomical_structureTearsTearsDry Eye SyndromesFemaleSurgerysense organsOphthalmic SolutionsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Retinal light sensitivity of the central visual field among 70- to 81-year-old men and women.

2009

Retinal light sensitivity of the central visual field (0-30 degrees), visual acuity, intraocular pressure and pupillary size were screened in 42 men and 42 women aged 70 to 81 years. The subjects were randomly selected from the population register. After excluding the diagnosed glaucoma cases, the men had better visual field light sensitivity values than the women. They also had lower intraocular pressure and a wider pupillary diameter than the women, whereas there were no differences in visual acuity between the sexes. When the effect of pupillary size was controlled the differences in visual field light sensitivity values between men and women became non-significant. Among these elderly p…

Malemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresLightVisual AcuityGlaucomaRetinachemistry.chemical_compoundRandom AllocationOphthalmologymedicineHumansCentral visual fieldIntraocular PressureAgedAged 80 and overLight sensitivitybusiness.industryRetinalPupilGeneral Medicinemedicine.diseaseeye diseasesVisual fieldOphthalmologychemistrySensory ThresholdsOptometryFemalemedicine.symptomVisual FieldsbusinessPopulation RegisterActa ophthalmologica
researchProduct

Sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsular rupture in cataract surgery.

2012

Purpose. To evaluate the safety of a foldable acrylic single-piece intraocular lens (IOL) in cases of complicated cataract surgery and sulcus implantation. The setting was University and private anterior segment surgery practices. Methods. In this observational case series study, 13 eyes of 13 patients were included after complicated phacoemulsification with extensive posterior capsule rupture with or without vitreous loss. A foldable acrylic single-piece IOL (Rayner Superflex 620H; Rayner Intraocular Lenses Limited, Hove, East Sussex, UK) was implanted in the ciliary sulcus in each eye. Postoperative follow-up included best-corrected visual acuity, anterior segment biomicroscopy, IOL centr…

Malemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensFundus (eye)PupilPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansIntraocular PressureAgedAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicinePhacoemulsificationCataract surgerySulcusMiddle AgedPosterior Capsular Rupture Oculareye diseasesSurgeryOphthalmologymedicine.anatomical_structureFemalesense organsmedicine.symptombusinessEuropean journal of ophthalmology
researchProduct

Pupil size differences between female and male patients after cataract surgery.

2022

Purpose To evaluate the changes in pupil diameter in women and men after cataract surgery. The correlation of pupillary changes with the variables age and anterior chamber depth will be analyzed. Methods The values of 109 randomized eyes who underwent cataract surgery were obtained and divided into two groups, 71 women and 38 men. Pupil diameter was measured preoperatively and 3-months postoperatively using the pupillometer software of the Topolyzer Vario (Wavelight Laser Technologie AG). Anterior chamber depth was obtained with Pentacam® (Oculus). Differences in pupillary diameters were investigated and correlations with age and anterior chamber depth were analyzed. Results For mesopic pup…

Malemedicine.medical_specialtyLightMesopic visionmedicine.medical_treatmentUlls -- AnatomiaAfter cataractGender-related effectPupilCataract03 medical and health sciences0302 clinical medicineEye -- AnatomyMedicineHumansClinical significanceAnterior chamberPupil disordersbusiness.industryPupil sizePupilCataract surgerySurgeryMale patient030221 ophthalmology & optometryCataractes:Ciències de la visió [Àrees temàtiques de la UPC]Femalesense organsbusiness030217 neurology & neurosurgeryAge factorsOptometryPhotopic visionJournal of optometry
researchProduct

Lack of effect of intraocular lens asphericity on visual performance with acrylic intraocular lenses.

2011

Purpose. To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods. In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results. Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and…

Malemedicine.medical_specialtyOptics and PhotonicsVisual acuityMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityLens Implantation IntraocularOphthalmologyMedicineContrast (vision)Humansmedia_commonAgedAged 80 and overLenses Intraocularbusiness.industryStrehl ratioGeneral MedicineMiddle AgedOphthalmologySpherical aberrationFemalemedicine.symptombusinessPhotopic visionEuropean journal of ophthalmology
researchProduct

Impact of lens material on objective refraction in eyes with trifocal diffractive intraocular lenses

2021

Purpose: Compare subjective (Rx) and objective (ObjRx) refractions outcomes with two autorefractors models and an aberrometer in eyes implanted with a hydrophobic trifocal IOL (FineVision POD F GF, Physiol, Liége, Belgium) and a hydrophilic one (FineVision POD F, Physiol, Liége, Belgium). Methods: Prospective comparative cohort study, with 100 subjects randomly assigned to either the POD F group (n = 50) or the POD F-GF group (n = 50). Postoperative eye examinations at 1-month visit included seven result sets, one for each assessment method: Rx, AR (automated refraction measured with the autorefractor KR8800), WF-P (Zernike-coefficients-based objective refraction, photopic pupil size), WF-M…

Malemedicine.medical_specialtyPseudophakiaMesopic visionmedicine.medical_treatmentVisual AcuityUlls -- Acomodació i refraccióIntraocular lensRefraction OcularIntraocular lensesPupillaw.invention03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicinelawOphthalmologymedicineHumansPostoperative PeriodProspective StudiesMathematicsAgedEye -- Accomodation and refractionVision BinocularIntraocular lensOpticsTrifocal diffractiveLents intraocularsHydrofilicRefractionSubjective refractionMultifocal Intraocular LensesSensory SystemsLens (optics)OphthalmologyRefractionAutorefractorPatient SatisfactionDifracció030221 ophthalmology & optometryFemale:Ciències de la visió [Àrees temàtiques de la UPC]Diffraction030217 neurology & neurosurgeryHydrofobicPhotopic visionFollow-Up Studies
researchProduct