Pharmacologic pupil dilation as a predictive test for the risk for intraoperative floppy-iris syndrome.
2011
PURPOSE: To evaluate the effect of α1-adrenergic receptor antagonists (α1-ARAs) on pupil diameter and determine whether the diameter predicts intraoperative floppy-iris syndrome (IFIS). SETTING: Ophthalmology Section, Palermo University, Palermo, Italy. DESIGN: Prospective cohort study. METHODS: Male outpatients taking tamsulosin, α(1)-ARAs, or no α(1)-ARAs having phacoemulsification were recruited. Pupils were measured 1 month preoperatively, immediately preoperatively, and postoperatively under mesopic low (0.4 lux) and high (4.0 lux) illumination after pharmacologic dilation. The IFIS severity was graded. RESULTS: Each group comprised 50 patients. Pharmacologic dilation in both α(1)-ARA …
Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.
2014
Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …
Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens
2007
To determine whether pupil size is correlated with visual acuity and contrast sensitivity at all distances in eyes with an apodized diffractive intraocular lens (IOL).Private Clinic, Oviedo, Spain.Six months after surgery, the best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were measured in 670 eyes of 335 consecutive patients who had implantation of the AcrySof ReSTOR Natural IOL (SN60D3, Alcon). Pupil diameters in distance vision were measured using a pupillometer.The logMAR best corrected distance acuity was significantly better with …
Perioperative pupil size in low-energy femtosecond laser-assisted cataract surgery
2020
Purpose To assess potential changes in pupil size during femtosecond laser-assisted cataract surgery (FLACS) using a low-energy laser system. Methods The pupil sizes of eyes undergoing FLACS were measured using the Ziemer LDV Z8 by extracting images from the laser software after each of the following steps: application of suction, lens fragmentation, and capsulotomy. Furthermore, the pupil diameters were measured based on preoperative surgical microscope images and after releasing the suction. Paired t-test and the two one-sided tests (TOST) procedure were used for statistical analyses. The horizontal and vertical pupil diameters were compared in each of the steps with preoperative values.…
Optical quality after instillation of eyedrops in dry-eye syndrome
2010
Purpose To study the effect of eyedrop instillation on the optical quality of the air–tear film interface at the anterior cornea in cases of dry eye. Setting University of Valencia, Valencia, Spain. Methods Corneal aberrations (total, spherical-like, and coma-like) were determined from corneal elevation maps and purpose-designed software in cases of dry eye before, immediately after, and 10 minutes after lubricating eyedrop instillation (Blink Intensive Tears). All data were decomposed using Zernike polynomials to yield the root-mean-square wavefront deviations for pupil diameters of 3.0 mm and 5.5 mm. Outcome measures included comparison with clinical tear breakup time (TBUT). Results Wave…
Retinal light sensitivity of the central visual field among 70- to 81-year-old men and women.
2009
Retinal light sensitivity of the central visual field (0-30 degrees), visual acuity, intraocular pressure and pupillary size were screened in 42 men and 42 women aged 70 to 81 years. The subjects were randomly selected from the population register. After excluding the diagnosed glaucoma cases, the men had better visual field light sensitivity values than the women. They also had lower intraocular pressure and a wider pupillary diameter than the women, whereas there were no differences in visual acuity between the sexes. When the effect of pupillary size was controlled the differences in visual field light sensitivity values between men and women became non-significant. Among these elderly p…
Sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsular rupture in cataract surgery.
2012
Purpose. To evaluate the safety of a foldable acrylic single-piece intraocular lens (IOL) in cases of complicated cataract surgery and sulcus implantation. The setting was University and private anterior segment surgery practices. Methods. In this observational case series study, 13 eyes of 13 patients were included after complicated phacoemulsification with extensive posterior capsule rupture with or without vitreous loss. A foldable acrylic single-piece IOL (Rayner Superflex 620H; Rayner Intraocular Lenses Limited, Hove, East Sussex, UK) was implanted in the ciliary sulcus in each eye. Postoperative follow-up included best-corrected visual acuity, anterior segment biomicroscopy, IOL centr…
Pupil size differences between female and male patients after cataract surgery.
2022
Purpose To evaluate the changes in pupil diameter in women and men after cataract surgery. The correlation of pupillary changes with the variables age and anterior chamber depth will be analyzed. Methods The values of 109 randomized eyes who underwent cataract surgery were obtained and divided into two groups, 71 women and 38 men. Pupil diameter was measured preoperatively and 3-months postoperatively using the pupillometer software of the Topolyzer Vario (Wavelight Laser Technologie AG). Anterior chamber depth was obtained with Pentacam® (Oculus). Differences in pupillary diameters were investigated and correlations with age and anterior chamber depth were analyzed. Results For mesopic pup…
Lack of effect of intraocular lens asphericity on visual performance with acrylic intraocular lenses.
2011
Purpose. To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods. In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results. Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and…
Impact of lens material on objective refraction in eyes with trifocal diffractive intraocular lenses
2021
Purpose: Compare subjective (Rx) and objective (ObjRx) refractions outcomes with two autorefractors models and an aberrometer in eyes implanted with a hydrophobic trifocal IOL (FineVision POD F GF, Physiol, Liége, Belgium) and a hydrophilic one (FineVision POD F, Physiol, Liége, Belgium). Methods: Prospective comparative cohort study, with 100 subjects randomly assigned to either the POD F group (n = 50) or the POD F-GF group (n = 50). Postoperative eye examinations at 1-month visit included seven result sets, one for each assessment method: Rx, AR (automated refraction measured with the autorefractor KR8800), WF-P (Zernike-coefficients-based objective refraction, photopic pupil size), WF-M…