Search results for "Pupila"

showing 6 items of 6 documents

Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system

2014

Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…

AdultMalemedicine.medical_specialtyAnterior ChamberScheimpflug principlePupil diameterIrisVergenceDiagnostic Techniques OphthalmologicalPupilAnterior chamber angleNear visionAnterior chamber eyeYoung AdultOpticslcsh:OphthalmologyOphthalmologyPhotographyMedicineHumansskin and connective tissue diseasesPupilaAnterior chamberCâmara anteriorTécnicas medidas equipamentos de mediçãobusiness.industryAccommodation OcularPupilGeneral Medicineeye diseasesOphthalmologyAcomodação ocularlcsh:RE1-994Accommodation ocularTechniques measures measurement equipmentFemalesense organsbusinessAccommodationTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices.

2014

Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured…

InterferometriaAdultAnterior ChamberScheimpflug principlePhotography/methodsPupil diameterIrisPupila/fisiologiaDiagnostic Techniques OphthalmologicalAnterior chamber anglePupilYoung AdultOpticsAnterior chamber/pathologyImaging Three-Dimensionallcsh:OphthalmologymedicineDiagnostic techniques ophthalmologicalPhotographyHumansPentacam hrDioptrePhysicsWhite to whitemedicine.diagnostic_testbusiness.industryPupilGeneral MedicineTécnicas de diagnóstico oftalmológicoCorneal topographyeye diseasesOphthalmologyInterferometryCâmara anterior/patologialcsh:RE1-994Fotografia/métodosTopografia da córneasense organsCorneal topographyPupil/physiologybusinessNuclear medicineArquivos brasileiros de oftalmologia
researchProduct

Medida da profundidade da câmara anterior, distância branco a branco, ângulo da câmara anterior e diâmetro pupilar usando dois dispositivos de imagen…

2014

Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured…

InterferometriaAnterior chamber/pathologyInterferometryCâmara anterior/patologiaPhotography/methodsFotografia/métodosDiagnostic techniques ophthalmologicalTopografia da córneaCorneal topographyPupil/physiologyPupila/fisiologiaTécnicas de diagnóstico oftalmológico
researchProduct

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.

2014

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectLentes de contatoVisual AcuityPupilContrast Sensitivitylcsh:OphthalmologymedicineContrast (vision)HumansContact lensesPresbyopia/rehabilitationPupilaPresbiopia/reabilitaçãomedia_commonMathematicsCross-Over StudiesColor VisionPupilGeneral MedicinePresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseContact Lenses HydrophilicAjuste de próteseeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment Outcomelcsh:RE1-994Dominância ocularOptometryFemalemedicine.symptomProsthesis fitting dominance ocularPhotopic visionArquivos brasileiros de oftalmologia
researchProduct

Práctica 2. Ajuste y toma de las medidas naso-pupilares de lejos con el talco de la gafa.

2018

Ajuste y toma de las medidas naso-pupilares de lejos con el talco de la gafa.

Medidas Naso-PupilaresUNESCO::FÍSICA
researchProduct

Interocular differences in visual quality due to ocular aberrations and scattering in a patient with post-traumatic anisocoria: A case report

2012

AbstractA 41-year-old patient with visual disturbances after an ocular trauma in right eye three years before was carefully analyzed and discussed. No corneal or intraocular sequelae were present. Only a significant anisocoria could be observed. Right eye (RE) achieved a best spectacle-corrected visual acuity (BSCVA) of 0.05 LogMAR with a refraction of +0.50 sphere and −1.25 cylinder. Left eye (LE) achieved a BSCVA of 0.0 LogMAR with a refraction of +0.75 sphere and −1.00 cylinder. In photopic conditions pupil diameter was 4.96mm for RE and 3.02mm for LE whereas in scotopic conditions, these values were 7.45mm and 6.71mm, respectively. More significant levels of higher-order corneal and ocu…

medicine.medical_specialtyVisual acuitygenetic structuresCase ReportPupilScatteringlcsh:OphthalmologyOphthalmologymedicinelcsh:QC350-467AberraciónScotopic visionPupilaAnisocoriabusiness.industryFunción de dispersión del puntoPupil sizePupilRefractionAnisocoriaPoint spread functioneye diseasesDispersiónlcsh:RE1-994Visual DisturbanceOptometrysense organsmedicine.symptombusinessAberrationlcsh:Optics. LightPhotopic visionOptometryJournal of Optometry
researchProduct