Search results for "QUADRUPOLE"

showing 10 items of 460 documents

HfF+ as a candidate to search for the nuclear weak quadrupole moment

2018

Nuclei with a quadrupole deformation, such as $^{177}\mathrm{Hf}$ have enhanced weak quadrupole moment which induces the tensor weak electron-nucleus interaction in atoms and molecules. Corresponding parity-non-conserving (PNC) effect is strongly enhanced in the ${}^{3}{\mathrm{\ensuremath{\Delta}}}_{1}$ electronic state of the $^{177}\mathrm{HfF}^{+}$ cation which has very close opposite parity levels mixed by this tensor interaction. In the present paper we perform relativistic many-body calculations of this PNC effect. It is shown that the tensor weak interaction induced by the weak quadrupole moment gives the dominating contribution to the PNC effects in $^{177}\mathrm{HfF}^{+}$ which s…

Chemical Physics (physics.chem-ph)PhysicsAtomic Physics (physics.atom-ph)Nuclear TheoryAtoms in moleculesFOS: Physical sciencesParity (physics)Weak interaction01 natural sciencesPhysics - Atomic Physics010305 fluids & plasmasPhysics - Chemical Physics0103 physical sciencesQuadrupoleNeutronPhysics::Atomic PhysicsAtomic physics010306 general physicsPhysical Review A
researchProduct

Towards high-accuracy mass spectrometry of highly charged short-lived ions at ISOLTRAP

2006

Dedicated to H.-J. Kluge on the occasion of his 65th birthday anniversary - Jürgen Kluge Special Issue; Multiply charged ions of stable xenon isotopes from a plasma ion source have been mass-selected by the on-line mass separator ISOLDE/CERN and delivered to the triple-trap mass spectrometer ISOLTRAP. The doubly charged ions that survived the charge-exchange processes during bunching and ion preparation were transferred to a precision Penning trap for mass determination. Mass values were obtained for the isotopes with mass numbers A=126,129,130,136. They are consistent with previous results except for the case of $^{126}Xe$ where a significant deviation from the literature value was found. …

atomic masses[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Thermal ionization mass spectrometryMass spectrometry01 natural sciencesISOLTRAPhistory of atomic massesNuclear physics0103 physical scienceshistory of mass spectrometryPhysical and Theoretical ChemistryNuclear Experiment010306 general physicsInstrumentationQuadrupole mass analyzerSpectroscopy010308 nuclear & particles physicsChemistryNuclear binding energiesHighly charged ionevaluation of atomic massesCondensed Matter PhysicsPenning trapIon sourceAtomic physicsHybrid mass spectrometerInternational Journal of Mass Spectrometry
researchProduct

Determination of type A and type B trichothecenes in paprika and chili pepper using LC-triple quadrupole-MS and GC-ECD.

2011

There is a need to develop sensitive and accurate analytical methods for determining deoxynivalenol (DON), HT-2 toxin and T-2 toxin in paprika to properly assess the relevant risk of human exposure. An optimized analytical method for determination of HT-2 toxin and T-2 toxin using capillary gas chromatography with electron capture detection and another method for determination of DON by liquid chromatography-mass spectrometry in paprika was developed. The method for determination of HT-2 toxin and T-2 toxin that gave the best recoveries involved extraction of the sample with acetonitrile-water (84:16, v/v), clean-up by solid-phase extraction on a cartridge made of different sorbent material…

Detection limitResidue (complex analysis)ChromatographyChromatography GasElutionChemistryExtraction (chemistry)Mass SpectrometryAnalytical ChemistryTriple quadrupole mass spectrometerT-2 ToxinHumansSample preparationGas chromatographySolid phase extractionCapsicumTrichothecenesChromatography LiquidTalanta
researchProduct

Electric hyperfine interaction in199Hg fluorides

1985

With the current integration technique, the Mossbauer effect on the 158 keV, 5/2−→1/2− transition in199Hg was studied using the cubic HgF2 and the tetragonal Hg2F2 as absorbers; in the latter, a quadrupole splittingeQVzz=}- 9.0(2) mm/s was observed. Electron densities were calculated with the self-consistent-charge-extended-Hueckel-molecular-orbital method and δ〈r2〉=(3.26±0.11) fm2 derived. From the quadrupole splitting and the calculation, an effective antishielding factor almost twice that of the neutral Hg atom is derived.

Nuclear and High Energy PhysicsMössbauer effectChemistryHalideElectronQuadrupole splittingCondensed Matter PhysicsAtomic and Molecular Physics and OpticsTetragonal crystal systemQuadrupoleAtomPhysical and Theoretical ChemistryAtomic physicsHyperfine structureHyperfine Interactions
researchProduct

Bose-Einstein Condensation in an electro-pneumatically transformed quadrupole-Ioffe magnetic trap

2014

We report a novel approach for preparing a Bose-Einstein condensate (BEC) of $^{87}$Rb atoms using electro-pneumatically driven transfer of atoms into a Quadrupole-Ioffe magnetic trap (QUIC Trap). More than 5$\times$$10^{8}$ atoms from a Magneto-optical trap are loaded into a spherical quadrupole trap and then these atoms are transferred into an Ioffe trap by moving the Ioffe coil towards the center of the quadrupole coil, thereby, changing the distance between quadrupole trap center and the Ioffe coil. The transfer efficiency is more than 80 \%. This approach is different from a conventional approach of loading the atoms into a QUIC trap wherein the spherical quadrupole trap is transformed…

PhysicsCondensed Matter::Quantum GasesQuantum PhysicsAtomic Physics (physics.atom-ph)Condensed Matter::OtherCondensationGeneral Physics and AstronomyFOS: Physical scienceslaw.inventionPhysics - Atomic PhysicsTrap (computing)lawElectromagnetic coilPhase spaceMagnetic trapQuadrupolePhysics::Atomic PhysicsAtomic physicsQuantum Physics (quant-ph)Bose–Einstein condensateEvaporative cooler
researchProduct

A highly selective laser ion source for bunched, low emittance beam release

2004

A novel type of resonance ionization laser ion source (RILIS) is under development, which combines the advantages of laser ionization with those of a source-implemented ion trap. This laser ion source trap (LIST) system, based on a gas-filled linear radio-frequency quadrupole ion trap, decouples the evaporation and ionization process by introduction of a primary surface ion repeller. Apart from significantly enhancing the selectivity in radioactive ion beam production, optimum control on the temporal pulse structure and the emittance of the generated laser ion bunch is obtained. A variety of operational modes from quasi-dc to microseconds-bunched ion beams with variable repetition rate can …

PhysicsNuclear and High Energy PhysicsIon beamIon gunIon sourcelaw.inventionSecondary ion mass spectrometryIon beam depositionPhysics::Plasma PhysicsReflectronlawPhysics::Accelerator PhysicsPhysics::Atomic PhysicsIon trapAtomic physicsQuadrupole ion trapNuclear Physics A
researchProduct

Permanent magnet system to guide superparamagnetic particles

2017

A new concept of permanent magnet systems for guiding superparamagnetic particles on arbitrary trajectories is proposed. The basic concept is to use one magnet system with a strong and homogeneous (dipolar) magnetic field to magnetize and orient the particles. A second constantly graded field (quadrupolar) is superimposed to the first to generate a force. In this configuration the motion of the particles is driven solely by the component of the gradient field which is parallel to the direction of the homogeneous field. Then the particles are guided with constant force in a single direction over the entire volume. The direction can be adjusted by varying the angle between quadrupole and dipo…

010302 applied physicsPhysicsMagnetic momentCondensed matter physicsFOS: Physical sciences02 engineering and technologyMechanics021001 nanoscience & nanotechnologyCondensed Matter PhysicsPolarization (waves)Physics - Medical Physics01 natural sciencesElectronic Optical and Magnetic MaterialsMagnetic fieldDipoleMagnet0103 physical sciencesQuadrupoleVector fieldMedical Physics (physics.med-ph)0210 nano-technologyQuadrupole magnetJournal of Magnetism and Magnetic Materials
researchProduct

Optimization of LC–MS/MS using triple quadrupole mass analyzer for the simultaneous analysis of carbosulfan and its main metabolites in oranges

2006

This paper describes an analytical method involving a simple solvent extraction for the simultaneous liquid chromatography coupled to quadrupole tandem mass spectrometry (LC-MS/MS) determination of carbosulfan, its most toxic metabolite--carbofuran--, and its other main metabolites--3-hydroxycarbofuran, 3-ketocarbofuran, 3-hydroxy-7-phenolcarbofuran, 3-keto-7-phenolcarbofuran, 7-phenolcarbofuran and dibutylamine--in oranges. Chromatography was performed on a Zorbax Bonus-RP (150 mm x 2.1 mm, 5 microm). The mobile phase was a ternary gradient water-methanol-acetonitrile with 1.0 mM ammonium acetate at flow rate of 0.2 ml min(-1). The LC separation and MS/MS optimization were studied to selec…

Detection limitChromatographyMetaboliteAnalytical chemistryTandem mass spectrometryBiochemistryAnalytical ChemistryTriple quadrupole mass spectrometerStandard curvechemistry.chemical_compoundchemistryLiquid chromatography–mass spectrometryEnvironmental ChemistrySample preparationCarbosulfanSpectroscopyAnalytica Chimica Acta
researchProduct

Optical polarization of neutron-rich sodium isotopes and β-NMR measurements of quadrupole moments

1996

The nuclear quadrupole moments of neutron-rich sodium isotopes are being investigated with the help of in-beam polarization by optical pumping in combination with $\beta$-NMR techniques. First measurements have yielded the quadrupole splittings of NMR signals in the lattice of LiNbO$_{3}$ for the isotopes $^{26}$Na, $^{27}$Na and $^{28}$Na. Interaction constants and ratios of the electric quadrupole moments are derived. In view of future experiments, $\beta$-decay asymmetries for the sequence of isotopes up to the $N$=20 neutron shell closure, $^{26-31}$Na, have been measured.

Nuclear and High Energy PhysicsIsotopeChemistryNuclear TheoryAnalytical chemistryOptical polarizationQuadrupole splittingCondensed Matter PhysicsIsotopes of sodiumPolarization (waves)Atomic and Molecular Physics and OpticsOptical pumpingQuadrupolePhysics::Accelerator PhysicsNuclear Physics - ExperimentNeutronPhysics::Atomic PhysicsPhysical and Theoretical ChemistryAtomic physicsNuclear Experiment
researchProduct

On-line implementation and first operation of the Laser Ion Source and Trap at ISOLDE/CERN

2015

13 pags.; 12 figs.; 2 tab.; Open Access funded by CERN

Laser ion sourceNuclear reactionSpeichertechnik - Abteilung BlaumNuclear and High Energy PhysicsRILISIon beamChemistryResonance Ionization Laser Ion SourceThermal ionizationOn-line mass separatorLaserAccelerators and Storage RingsIon sourceIonlaw.inventionLISTlawIonizationQuadrupoleAtomic physicsInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct