Search results for "R measurement"

showing 10 items of 111 documents

"Table 3" of "Cross-sections and leptonic forward-backward asymmetries from the Z0 running of LEP."

2000

Hadronic cross section measured with the 1995 data. Additional systematic error of 0.10 PCT (efficiencies and backgrounds) and 0.11 PCT (absolute luminosity).

congenital hereditary and neonatal diseases and abnormalities89.438-92.965E+ E- --> HADRONSE+ E- Scatteringparasitic diseasesIntegrated Cross SectionExclusiveCross SectionR measurementbacterial infections and mycosesSIGhormones hormone substitutes and hormone antagonists
researchProduct

"Table 1" of "Cross-sections and leptonic forward-backward asymmetries from the Z0 running of LEP."

2000

Hadronic cross section measured with the 1993 data. Additional systematic error of 0.10 PCT (efficiencies and backgrounds) and 0.29 PCT (absolute luminosity).

congenital hereditary and neonatal diseases and abnormalitiesE+ E- --> HADRONSE+ E- Scatteringparasitic diseasesIntegrated Cross SectionExclusive89.431-93.015Cross SectionR measurementbacterial infections and mycosesSIGhormones hormone substitutes and hormone antagonists
researchProduct

Riferibilità dei contatori statici di energia reattiva in presenza di armoniche. Evoluzione normativa e prove sperimentali

2013

energy measurement power measurement reactive power static meters reference standard meters harmonic distortionSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Traceability of static reactive energy meters in the presence of harmonics: theoretical considerations and a DAQ-based reference meter

2013

This paper deals with some problems related to the measurements traceability with static meters for reactive energy. These problems arise when the meters operate in the presence of harmonics, which can negatively affect their performances, depending on implemented metric. The paper analyzes the problem in the light of both in-force and draft standards, from the viewpoint of the performances of both commercial meters and reference standard instruments. The analysis is supported by some experimental tests, which are carried out by means of a reference meter, based on data acquisition boards, which can be used in both sinusoidal and distorted conditions.

energy measurement power measurement reactive power static meters reference standard meters harmonic distortionSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

The effects of image compression on quantitative measurements of digital panoramic radiographs

2012

WOS: 000314401800026

fractal dimensionPanoramic radiographOdontologíaangular measurementsMandibular first molarFractal dimensionstomatognathic systemClinical and Experimental DentistryRadiography PanoramicHumansGonial angleDigital panoramic radiographyeducationGeneral DentistryMathematicsObserver VariationOrthodonticseducation.field_of_studyRadiography Dental DigitalRepeatabilitycomputer.file_formatData Compression:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludJPEGimage compressionTagged Image File FormatOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASlinear measurementsResearch-ArticleSurgerycomputerData compressionMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

IEEE Std. 1459 power quantities ratio approaches for simplified harmonic emissions assessment

2018

The paper investigates the suitability of using power ratio parameters for harmonic emissions assessment at the point of common coupling (PCC). The study is carried out starting from the IEEE Std. 1459-2010 apparent power decomposition, where power factors are defined for evaluating line utilization and harmonic pollution levels. In addition, the study investigates the behavior of new parameters, which are expressed in terms of ratio between IEEE Std. 1459-2010 power quantities. The study is carried out for both single-phase and three-phase case, also considering the presence of capacitors. ? 2018 IEEE.

harmonic sources; IEEE Std. 1459-2010; power definitions; power measurement; power quality020209 energy02 engineering and technologyAC powerAutomotive engineeringlaw.inventionPower (physics)harmonic distortionHarmonic analysisCapacitorHarmonic pollutionlawPower ratio0202 electrical engineering electronic engineering information engineeringHarmonicPoint of common couplingPower measurement harmonic distortion power definitions power quality IEEE Std. 1459-2010 harmonic sourcesSettore ING-INF/07 - Misure Elettriche E ElettronicheMathematics2018 18th International Conference on Harmonics and Quality of Power (ICHQP)
researchProduct

Current transformers effects on the measurement of harmonic active power in LV and MV networks

2011

The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …

instrument transformersEngineeringVoltage and current harmonicsSwitched-mode power supplyAcousticsActive powerTransducersEnergy Engineering and Power TechnologyLinear currentsPower factorHarmonic powerLinear transducersPower errorsPower transformersVoltage transducersHarmonic analysisHarmonic analysisMaximum valuesCurrent transformerElectrical and Electronic EngineeringPower measurementPhase anglesAbsolute valuesHarmonic power flowTotal harmonic distortionbusiness.industryElectric power distributionCurrent harmonicsElectrical engineeringAC powerCurrent transformerMV networksHarmonicsAccuracy classElectric instrument transformersHarmonicPower system harmonicsCurrent transformers (CTs) instrument transformerspower measurement power system harmonics.businessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Color-discrimination threshold determination using pseudoisochromatic test plates

2014

We produced a set of pseudoisochromatic plates for determining individual color-difference thresholds to assess test performance and test properties, and analyzed the results. We report a high test validity and classification ability for the deficiency type and severity level [comparable to that of the fourth edition of the Hardy–Rand–Rittler (HRR) test]. We discuss changes of the acceptable chromatic shifts from the protan and deutan confusion lines along the CIE xy diagram, and the high correlation of individual color-difference thresholds and the red–green discrimination index. Color vision was tested using an Oculus HMC anomaloscope, a Farnsworth D15, and an HRR test on 273 schoolchildr…

medicine.medical_specialtygenetic structurescolor-vision defectsColor visionlcsh:BF1-990color-vision deficiencyColor Vision DefectsTest validityAudiologycolor measurementColor discriminationvision systempsychophysicscolor perceptionmedicinePsychologyOriginal Research ArticleChromatic scaleGeneral PsychologyConfusioncolor vision deficiencyTest (assessment)Anomaloscopelcsh:Psychologycolor visionColor Vision DefectsOptometrymedicine.symptomPsychologyFrontiers in Psychology
researchProduct

Harmonic sources detection in power systems via nonactive power measurements according to IEEE Std. 1459-2010: theoretical approach and experimental …

2010

In this paper an enhanced decision-making strategy is presented for the detection of harmonic sources in power systems able to detect also which is the prevailing nature of the disturbance (nonlinearity or unbalance). It makes use of some simple indices, which are evaluated by means of the measurements of some nonactive power quantities, proposed by the authors and derived from the approach of the IEEE Std. 1459-2010. The decision-making rules for the proposed strategy are presented and discussed by means of simulation and experimental tests. The results obtained are presented, showing the effectiveness of the proposed strategy for the detection of the dominant harmonic source upstream or d…

power measurement harmonic distortion power definitions IEEE Std. 1459-2010 harmonic sourcesSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Studio e sviluppo di innovativi sistemi di misura e di comunicazione per le smart grid

smart grid power quality analyzer PMU phasor measurement unit rete isolata SCADASettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct