Search results for "R measurement"

showing 10 items of 111 documents

"Table 3" of "Inclusive production of the omega and eta mesons in Z decays, and the muonic branching ratio of the omega."

2002

Production rate and differential cross sections for the OMEGA.

E+ E- --> OMEGA XInclusiveSingle Differential Cross SectionE+ E- --> HADRONSE+ E- ScatteringIntegrated Cross SectionExclusive91.2Cross SectionR measurementDSIG/DXSIG
researchProduct

"Table 1" of "Strange baryon production in Z hadronic decays"

1995

No description provided.

E+ E- --> SIGMA(1385P13)- XE+ E- --> SIGMA(1385P13)+ XE+ E- --> HADRONSE+ E- --> Z0Integrated Cross SectionE+ E- --> SIGMA+ X91.2Cross SectionSIGMULTInclusiveE+ E- --> XIBAR+ XE+ E- --> XI(1530P13)0 XE+ E- ScatteringE+ E- --> SIGMA- XE+ E- --> XI- XExclusiveR measurement
researchProduct

"Table 4" of "A Precise Determination of the Number of Families With Light Neutrinos and of the $Z$ Boson Partial Widths"

1990

No description provided.

E+ E- --> TAU+ TAU-Electron productionE+ E- --> HADRONSIntegrated Cross SectionCross SectionSIGMuon productionE+ E- --> E+ E-ElasticE+ E- --> MU+ MU-E+ E- ScatteringExclusiveTau productionR measurement91.182
researchProduct

"Table 1" of "Measurement of the production rates of eta and eta-prime in hadronic Z decays"

1992

No description provided.

Electron productionE+ E- --> HADRONSE+ E- --> Z0E+ E- --> ETAPRIME XIntegrated Cross SectionDeep Inelastic Scattering91.2Cross SectionE+ E- --> ETA XSIGInclusiveE+ E- ScatteringExclusiveR measurement
researchProduct

"Table 2" of "Inclusive production of the omega and eta mesons in Z decays, and the muonic branching ratio of the omega."

2002

Production rate and differential cross sections for the ETA.

Electron productionE+ E- --> HADRONSIntegrated Cross SectionDeep Inelastic Scattering91.2respiratory systemCross SectionE+ E- --> ETA XDSIG/DXSIGInclusiveSingle Differential Cross SectionE+ E- Scatteringcardiovascular systemExclusiveHigh Energy Physics::ExperimentR measurementNuclear Experimentcirculatory and respiratory physiology
researchProduct

LV Measurement Device Placement for Load Flow Analysis in MV Smart Grids

2016

This paper deals with the issue of measurement device placement for load flow analysis in medium-voltage (MV) distribution networks. The study is carried out using an innovative measurement algorithm for load flow analysis developed by the authors. It is based on low-voltage (LV) load power measurements applied on a backward/forward algorithm for the load flow resolution. The final aim is to identify the most suitable number and placement of the LV measurement points in order to limit the uncertainty on the power flow estimation to a target value. The proposed approach is based on the uncertainty evaluation of the estimated power flows; a sensitivity analysis is performed in order to assess…

Engineering020209 energy02 engineering and technologyPower factormeter placementpower system monitoringControl theorysmart grids0202 electrical engineering electronic engineering information engineeringElectronic engineeringpower measurementsPower-flow studySensitivity (control systems)Electrical and Electronic EngineeringInstrumentationbusiness.industry020208 electrical & electronic engineeringpower quality analyzer (PQA)power system measurementsPower (physics)Smart gridload flow (LF) analysisFlow (mathematics)Advanced metering infrastructure load flow (LF) analysis meter placement power measurements power quality analyzer (PQA) power system measurements power system monitoring smart grids.Advanced metering infrastructureMeasurement uncertaintyAlgorithm designbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheIEEE Transactions on Instrumentation and Measurement
researchProduct

Uncertainty evaluation in the measurements for the electric power quality analysis

2013

The paper deals with the uncertainty estimation in the measurements performed to assess the electric power quality. In a first steps, according to the 'ISO - Guide to Expression of the Uncertainty in Measurements' all the error sources, which give a significant contribution to the combined uncertainty associated to the measurement results, are identified. Successively, in order to analyze how the errors propagate through the measurement chain, a Monte Carlo based approach is proposed. The method exploits an ad-hoc developed simulator of the measurement process, which takes into account the particular way of propagation of all the identified error sources. Eventually, with the aim of validat…

EngineeringElectric power qualitymeasurement standardpower system measurementMeasurement uncertaintyMonte Carlo methodpower supply qualitySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciPower measurementpower quality analysisUncertainty analysisObservational errorelectric power quality analysiSeries (mathematics)business.industryProcess (computing)UncertaintyData acquisitionmeasurement uncertainty evaluationerror source identificationCurrent measurementExpression (mathematics)Reliability engineeringmeasurement systemISO standardguide to expression of the uncertainty in measurementMeasurement uncertaintybusinessad hoc developed simulatorNoiseAlgorithmSettore ING-INF/07 - Misure Elettriche E Elettronichemeasurement error
researchProduct

Electric Power Quality Evaluation in the Presence of Electromagnetic Emissions

2013

The measurements for the assessment of the electric power quality are often carried out in hostile electromagnetic environments. The aim of the paper is analyzing if and how both radiated and conducted electromagnetic emissions can disturb the measurement system used to quantify these disturbances. To achieve the target, an experimental approach is proposed, which, by means of a simple and fast test, allows establishing if the real electromagnetic environment, where power quality analysis is performed, can alter the measurements. © 2013 IEEE.

EngineeringElectric power qualityradiated electromagnetic emissionElectromagnetic environmentpower measurementpower supply qualityelectromagnetic waveSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciElectromagnetic radiationelectric power quality measurementFrequency measurementElectronic engineeringpower system faultFrequency modulationconducted electromagnetic emissionpower quality analysisdisturbancebusiness.industrySystem of measurementElectromagnetic compatibilitypower quality analysiVoltage measurementInstrumentTime measurementelectromagnetic immunity; power quality analysisStandardElectromagneticmeasurement systemelectromagnetic immunityPower qualityhostile electromagnetic environmentbusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

A PC-based wattmeter for high accuracy power measurements

2010

This paper proposes the use of a commercial data acquisition board (DAQ) connected to a common personal computer for high accuracy power measurements. In the paper the set up of the PC-based wattmeter is described and an experimental evaluation of its metrological performances is made by means of the comparison with a simultaneous coherent digital sampling wattmeter realized with two high-precision DMMs Hewlett Packard Model 3458 A. In both cases the power source is a Fluke 6100A/E electrical power standard. © 2010 IEEE.

EngineeringExperimental evaluationHigh-precisionElectric power measurementlaw.inventionPC-basedPower sourcesSet (abstract data type)Data acquisitionSampling (signal processing)lawElectronic engineeringPower measurementMeasurement theoryHewlett Packard modelsbusiness.industryData acquisition boardDigital samplingElectrical engineeringMetrological performanceWattmeterElectrical powerelectric power measurement digital sampling wattmeters data acquisition board pc-based instrumentPower (physics)MetrologyPersonal computersElectrical power measurementsPersonal computerElectric powerbusinessInstrumentsSettore ING-INF/07 - Misure Elettriche E ElettronicheWattmetersElectric power supplies to apparatus
researchProduct

A DAQ-based sampling wattmeter for IEEE Std. 1459-2010 powers measurements. Uncertainty evaluation in nonsinusoidal conditions

2015

Abstract This paper presents the evaluation of the metrological performances of a DAQ-based sampling wattmeter (DAQ-SW) for the measurement of IEEE Std. 1459-2010 power quantities in non-sinusoidal conditions. The instrument makes use of two commercial data acquisition (DAQ) boards, a non-inductive current shunt, a personal computer and a commercial software for data processing. Starting from the results of an experimental characterization of the two instrument channels with non-sinusoidal voltages and currents and a correlation analysis, the combined standard uncertainties of IEEE Std. 1459-2010 quantities are evaluated, following the approach of the ISO Guide to the Expression of Uncertai…

EngineeringPC-based instrumentsHarmonic distortionlaw.inventionData acquisitionlawElectronic engineeringElectrical and Electronic EngineeringPower measurements IEEE Std. 1459-2010 Data acquisition Uncertainty Harmonic distortion PC-based instrumentsInstrumentationIEEE Std. 1459-2010Data processingTotal harmonic distortionCommercial softwarebusiness.industryApplied MathematicsElectrical engineeringUncertaintyData acquisitionWattmeterCondensed Matter PhysicsMetrologyPersonal computerMeasurement uncertaintybusinessSettore ING-INF/07 - Misure Elettriche E ElettronichePower measurements
researchProduct