Search results for "R42"

showing 5 items of 5 documents

Experimental performance evaluation of a vapour compression refrigerating plant when replacing R22 with alternative refrigerants

2011

Abstract This paper presents the results of an experimental analysis comparing the performance of a vapour compression refrigerating unit operating with R22, and its performance in comparison to a new HFC fluid, substituting the former according to Regulation No 2037/2000. In particular, the plant working efficiency was first tested with R22 and then with three new HFC fluids: R417A, R422A and R422D. The investigation verified that despite the case of substitution and the advantage of being able to continue to use mineral oil as a lubricant in the compressor, the performance with the new tested fluids did not result as efficient as when using R22.

Engineeringbusiness.industryMechanical EngineeringAlternative refrigerantThermodynamicsBuilding and ConstructionManagement Monitoring Policy and LawCompression (physics)R22RefrigerantGeneral EnergyR422DmedicineSettore ING-IND/10 - Fisica Tecnica IndustrialeR417ALubricantMineral oilbusinessProcess engineeringR422AGas compressormedicine.drug
researchProduct

A Testing Facility for Refrigerating Plants Equipment Working with New Fluids

2013

A test rig was built in the department of energy, in laboratory of refrigerating engineering for test runs with a lot of fluid and equipment of various kind for commercial refrigeration. The facility has been continuously improved during the past years and allows to perform experiments aiming to assess the performance characteristics both of conventional and new equipment for commercial refrigeration. In the test rig can be tested a lot of cooling loop filled with a secondary fluid for simulation of their behavior in industrial and commercial plants (e.g.: during exploitation in supermarket and hypermarket for refrigeration of foodstuffs in cold store, display cases and cabinets, etc.). The…

Engineeringbusiness.industryTest rigRefrigerationGeneral MedicineR22Automotive engineeringRefrigerating plantsCold storeSettore ING-IND/10 - Fisica Tecnica IndustrialeHypermarketR422AbusinessSimulationApplied Mechanics and Materials
researchProduct

Project Management in the Port Development Project in Latvia

2016

Paper analyse case study of performance and compliance audit in the port development project in Latvia. Author has participated in the audit process evaluating project management application practical approach in the project implemented by the Riga Freeport Authority and co-funded by the Cohesion Fund “Development of Infrastructure on Krievu Island for the Transfer of Port Activities from the City Centre”. Despite the mass media reports that the Riga Freeport Authority has successfully completed the project, only the construction phase of the project has been completed. During the following two years the stevedore activity must be transferred to the newly built port infrastructure on Krievu…

H43 - Project Evaluation ; Social Discount RateR11 - Regional Economic Activity: Growth Development Environmental Issues and ChangesR42 - Government and Private Investment Analysis ; Road Maintenance ; Transportation PlanningO22 - Project Analysis
researchProduct

Comment réduire les émissions de CO2 du transport de fret en France ? Évaluation socio-économique de trois politiques publiques

2018

France must implement voluntarist policies in order to reduce CO2 emissions, which raises questions regarding the effectiveness of competing options and their costs, for both public finances and society. This paper estimates abatement costs of one ton of CO2 from three scenarios aimed at softening the environmental impacts of freight moved by trucks. Hybrid trucks may generate large CO2 savings (5.7 Mt/year in 2030), at a moderate discounted abatement cost (88 €/t). The option based on natural gas for vehicles leads to a similar abatement cost and to lower environmental gains (3.2 Mt/year in 2030). Whilst inducing small CO2 savings (0.2 Mt/year in 2030), megatrucks present a negative discou…

R40R42[SHS] Humanities and Social SciencesQ55Q58
researchProduct

Use of HFC fluids as suitable replacements in low-temperature refrigeration plants

2014

An experimental investigation of the performance of a low-temperature refrigerating unit working with R22 and a comparison of its performance when operating with replacement HFC fluids in accordance with the European Regulation CE-1005/2009 are presented in this paper. Plant working efficiency was tested with R22, as baseline, and then compared with four different HFC fluids: R413A, R417A, R422A and R422D. The refrigerating unit was a vapour-compression plant equipped with a reciprocating double-cylinder compressor able to keep the cold room at -20ºC. Lower values of the temperature at the end of compression and polytrophic exponent can be achieved with the HFC tested. Substituting the R22 …

R422dSettore ING-IND/10 - Fisica Tecnica IndustrialeRefrigerating systemR417aR422aR22R413a
researchProduct