Search results for "RADIATION"
showing 10 items of 5298 documents
Quality control for exposure assessment in epidemiological studies
2010
In the framework of an epidemiological study, dosemeters were used for the assessment of radio frequency electromagnetic field exposure. To check the correct dosemeter's performance in terms of consistency of recorded field values over the entire study period, a quality control strategy was developed. In this paper, the concept of quality control and its results is described. From the 20 dosemeters used, 19 were very stable and reproducible, with deviations of a maximum of +/- 1 dB compared with their initial state. One device was found to be faulty and its measurement data had to be excluded from the analysis. As a result of continuous quality control procedures, the confidence in the meas…
Suppression of radiative losses of surface polaritons on nanostructured thin metal films
2005
The strong electromagnetic coupling between surface plasmon polariton modes on opposite interfaces of a finite thickness periodically nanostructured metal film has been studied. Surface polariton dispersion and associated electromagnetic field distributions have been analyzed. It was shown that at a frequency that corresponds to the crossing of film Bloch modes of different symmetries, the radiative losses of surface polaritons that are related to the polaritons' coupling to light during propagation on the structured surface are suppressed.
Near-field properties of plasmonic nanostructures with high aspect ratio
2014
International audience; Using the Green's dyad technique based on cuboidal meshing, we compute the electromagnetic field scattered by metal nanorods with high aspect ratio. We investigate the effect of the meshing shape on the numerical simulations. We observe that discretizing the object with cells with aspect ratios similar to the object's aspect ratio improves the computations, without degrading the convergency. We also compare our numerical simulations to finite element method and discuss further possible improvements.
Mobile Phone Chips Reduce Increases in EEG Brain Activity Induced by Mobile Phone-Emitted Electromagnetic Fields
2018
Recent neurophysiological studies indicate that exposure to electromagnetic fields (EMFs) generated by mobile phone radiation can exert effects on brain activity. One technical solution to reduce effects of EMFs in mobile phone use is provided in mobile phone chips that are applied to mobile phones or attached to their surfaces. To date, there are no systematical studies on the effects of mobile phone chip application on brain activity and the underlying neural mechanisms. The present study investigated whether mobile phone chips that are applied to mobile phones reduce effects of EMFs emitted by mobile phone radiation on electroencephalographic (EEG) brain activity in a laboratory study. T…
Combined Effects of 50 Hz Electromagnetic Field and SiO2 Nanoparticles on Oxidative Stress in Plant’s Gametic Cells / Zemfrekvences (50 Hz) Elekromag…
2015
Abstract The paper presents the results of combined effects of an extremely low frequency electromagnetic field (50 Hz) (ELF EMF) and SiO2 nanoparticles on fluorescence of plant gametic cells (immature microspores). The data were recorded by a BD FACSJazz® cell sorter after cell irradiation by blue laser (488 nm). A significant difference of fluorescence was observed between gametic cells after 1 hour incubation in suspension of SiO2 nanoparticles and the control gametic cells. It was observed that fluorescence intensity of gametic cell was higher with ELF EMF treatment in comparison to control cells, but it was statistically significant only for cells treated with electromagnetic radiation…
A deep study of the high–energy transient sky
2021
This is an open access article. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds t…
Numerical procedures and their practical application in PV modules’ analyses. Part II: Useful fractions and APE
2019
Abstract The article regards aspects of PV modules tested with the use of natural sunlight. The analysis of spectral structure of solar energy resources in southern Poland, carried out on the basis of meteorological data originating from SolarLab PW Wroclaw and AGH Krakow, Poland [ 1 ] was used in the article. It is a continuation of the article: Analysis of solar energy resources in southern Poland for photovoltaic applications [ 1 ], describing the method to determine spectral parameters of average photon energy (APE) and useful fraction (UF) with the use of a solar radiation spectrum simulator. This article, however, includes an experimental presentation of their impact on PV conversion …
Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)
2020
A High-Granularity Timing Detector (HGTD) is proposed based on the Low-Gain Avalanche Detector (LGAD) for the ATLAS experiment to satisfy the time resolution requirement for the up-coming High Luminosity at LHC (HL-LHC). We report on beam test results for two proto-types LGADs (BV60 and BV170) developed for the HGTD. Such modules were manufactured by the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences (CAS) collaborated with Novel Device Laboratory (NDL) of the Beijing Normal University. The beam tests were performed with 5 GeV electron beam at DESY. The timing performance of the LGADs was compared to a trigger counter consisting of a quartz bar coupled to a SiPM read…
Preliminary application of thermoluminescence and single aliquot regeneration method for dose reconstruction in soda lime glass
2013
The research described in this paper shows that the use of the single aliquot regeneration (SAR) method for thermoluminescence (TL) measurements applied to soda lime glasses allows to carry out a retrospective dose evaluation. We have followed a fast and efficient sample preparation procedure which permits measurements without powdering and sieving processes. We have analyzed the TL signal of commercial soda lime watch glass irradiated with 6 Mega Volts (MV) LINAC photons, 10 MeV LINAC electrons and 62 MeV protons. After the initial exposure and following TL reading, the samples are successively irradiated with increasing doses of photons. Therefore, for each sample its calibration curve is…
Calibration of the width of the NI spectral line at for electron density determination
2002
Abstract The Stark broadening of a NI spectral line at 7915.42 A has been calibrated for electron density determination of low temperature plasmas. The determined simple formula based on measured FWHM is applicable in the electron density range from 3×1015 to 10 16 cm −3 .