Search results for "RADIATION"

showing 10 items of 5298 documents

Luminescence of a self-trapped exciton in GeO2 crystal

1993

Abstract The self-trapped exciton (STE) is discovered in the GeO2 crystal. A PL band at 2.5 eV with a strong Stokes shift is excited only in the fundamental absorption range of GeO2 crystal with the quantum yield about 0.4 and the decay time constant 800 ± 5 μs at 80 K. The PL thermal quenching occurs at 200 K with the energy about 0.25 eV and the frequency factor 107. At 4.5 K the PL decay kinetics splits into two components with time constants 270 μs and 8000 μs, which can be due to a triplet state split in the zero magnetic field. The STE in GeO2 is very similar to a STE in SiO2.

Condensed matter physicsChemistryExcitonQuantum yieldGeneral ChemistryCondensed Matter PhysicsCrystalsymbols.namesakeStokes shiftExcited stateMaterials ChemistrysymbolsAtomic physicsTriplet stateAbsorption (electromagnetic radiation)LuminescenceSolid State Communications
researchProduct

Computer modelling of radiation damage in cation sublattice of corundum

1998

Results of quantum chemical computer simulations of close Frenkel defects in corundum crystals are presented and discussed. The conclusion is drawn that the energy barrier for a back recombination up to fourth nearest neighbours is less than 0.3 eV, i.e. such pairs should be unstable at temperatures above 40 K.

Condensed matter physicsChemistrychemistry.chemical_elementCorundumElectronengineering.materialCondensed Matter PhysicsCrystallographic defectQuantum chemistryElectronic Optical and Magnetic MaterialsIonCrystallographyAluminiumRadiation damageengineeringSapphire
researchProduct

Coulomb blockade nanothermometer

1998

Reliable thermometry is normally based on commercial secondary sensors which are factory calibrated. Primary thermometers exist, too, but their use is limited because of intrinsic slowness, complex instrumentation, or inconvenient installation at the desired location. We have found that arrays of nanoscale tunnel junctions exhibit properties which are very suitable for primary and secondary cryogenic thermometry. Temperature range of this Coulomb blockade thermometer (CBT) extends over about two decades for one sensor and the mean temperature is lithographically adjustable. We have studied the performance of the CBT sensors at very low temperatures where the minimum temperature is limited b…

Condensed matter physicsbusiness.industryChemistryInstrumentationCoulomb blockadeElectronRadiationAtmospheric temperature rangeCondensed Matter::Mesoscopic Systems and Quantum Hall EffectCondensed Matter PhysicsAtomic and Molecular Physics and OpticsSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsMagnetic fieldTunnel junctionThermometerOptoelectronicsElectrical and Electronic EngineeringbusinessMicroelectronic Engineering
researchProduct

Evaluation of lens absorbed dose with Cone Beam IGRT procedures

2015

The purpose of this work is to evaluate the absorbed dose to the eye lenses due to the cone beam computed tomography (CBCT) system used to accurately position the patient during head-and-neck image guided procedures. The on-board imaging (OBI) systems (v.1.5) of Clinac iX and TrueBeam (Varian) accelerators were used to evaluate the imparted dose to the eye lenses and some additional points of the head. All CBCT scans were acquired with the Standard-Dose Head protocol from Varian. Doses were measured using thermoluminescence dosimeters (TLDs) placed in an anthropomorphic phantom. TLDs were calibrated at the beam quality used to reduce their energy dependence. Average dose to the lens due to …

Cone beam computed tomographyDosimeterPhantoms Imagingbusiness.industryPublic Health Environmental and Occupational HealthTruebeamRadiotherapy DosageGeneral MedicineCone-Beam Computed Tomographyequipment and supplieslaw.inventionLens (optics)lawAbsorbed doseLens CrystallineThermoluminescent DosimetryMedicineThermoluminescent Dosimetrysense organsLaser beam qualitybusinessNuclear medicineHeadWaste Management and DisposalImage-guided radiation therapyJournal of Radiological Protection
researchProduct

SU-E-J-69: Evaluation of the Lens Dose On the Cone Beam IGRT Procedures

2014

Purpose: With the establishment of the IGRT as a standard technique, the extra dose that is given to the patients should be taken into account. Furthermore, it has been a recent decrease of the dose threshold in the lens, reduced to 0.5 Gy (ICRP ref 4825-3093-1464 on 21st April, 2011).The purpose of this work was to evaluate the extra dose that the lens is receive due to the Cone-Beam (CBCT) location systems in Head-and-Neck treatments. Methods: The On-Board Imaging (OBI) v 1.5 of the two Varian accelerators, one Clinac iX and one True Beam, were used to obtain the dose that this OBI version give to the lens in the Head-and-Neck location treatments. All CBCT scans were acquired with the Sta…

Cone beam computed tomographyDosimeterbusiness.industryIsocenterGeneral Medicinelaw.inventionLens (optics)lawMedicineLaser beam qualityThermoluminescent dosimeterbusinessNuclear medicineBolus (radiation therapy)Image-guided radiation therapyMedical Physics
researchProduct

Dental CBCT equipment and performance issues

2012

Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As a new imaging modality, there were no established suspension levels at a European level. A literature review, encompassing scientific, professional publications and existing national guidelines was performed in an attempt to develop a set of suspension levels for dental CBCT, using additional expert opinion from the members of the European Academy of dento-maxillo-facial radio…

Cone beam computed tomographyEuropean levelmedicine.medical_specialtyImage qualityComputer scienceGuidelines as TopicComputed tomographyRadiation DosageDental EquipmentImaging Three-DimensionalImage Processing Computer-AssistedRadiography DentalmedicineHumansRadiology Nuclear Medicine and imagingMedical physicsRadiometryRadiationModality (human–computer interaction)Radiological and Ultrasound Technologymedicine.diagnostic_testX-RaysDental EquipmentPublic Health Environmental and Occupational HealthTesting equipmentReproducibility of ResultsEquipment DesignGeneral MedicineCone-Beam Computed TomographyClinical Practicestomatognathic diseasesToothRadiation Protection Dosimetry
researchProduct

Radiation dose in non-dental cone beam CT applications: a systematic review.

2018

Background: Radiation-induced health risks are broadly questioned in the literature. As cone beam computed tomography (CBCT) is increasingly used in non-dental examinations, its effective dose needs to be known. This study aimed to review the published evidence on effective dose of non-dental CBCT for diagnostic use by focusing on dosimetry system used to estimate dose. Materials and methods: A systematic review of the literature was performed on 12 November 2017. All the literature up to this date was included. The PubMed and web of science databases were searched. Studies were screened for inclusion based on defined inclusion and exclusion criteria according to the preferred reporting ite…

Cone beam computed tomographyRadiology Nuclear Medicine and ImagingComputed tomography dose indexCone beam computed tomographyRadiation DosageEffective dose (radiation)Imaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineMedicineDosimetryHumansSkeletal imagingEffective dosebusiness.industry030206 dentistryGeneral MedicineCone-Beam Computed TomographyParanasal sinusesmedicine.anatomical_structureDose area productInclusion and exclusion criteriabusinessNuclear medicineHeadNeckHead and neck imagingHumanLa Radiologia medica
researchProduct

Role of cone-beam computed tomography (CBCT) in diagnosis and treatment planning of two-rooted maxillary lateral incisor with palatogingival groove. …

2020

Background: The embryonic root groove is an anatomical abnormality that starts in the cingulum and extends longitudinally down the long axis root towards the apex. This developmental anomaly is more frequently reported in maxillary lateral incisors. Gu YC in 2011 established three types of radicular grooves depending on its severity. According to this classification, type III presents a greater diagnostic and therapeutic complexity. The prevalence of palatogingival grooves in maxillary lateral incisors ranges from 1.9 to 14%. This case report provides valuable information about the diagnosis and treatment plan of palatogingival grooves with Cone-beam computed tomography (CBCT) scan. Case re…

Cone beam computed tomographyTomografíaIncisivoOdontologíaCase ReportPalpationOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicineMedicina preventivastomatognathic systemMedicinePeriodontal ProbingBone regenerationRadiation treatment planningTecnología médicaGeneral DentistryGroove (engineering)Cingulum (tooth)Maxillary lateral incisorOrthodonticsmedicine.diagnostic_testbusiness.industry030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Anomalías dentariasstomatognathic diseasesUNESCO::CIENCIAS MÉDICASbusiness030217 neurology & neurosurgery
researchProduct

Raman investigation of single oxidized carbon nanotubes

2001

The oxidation process of single-walled carbon nanotubes via nitric acid treatment was followed by IR-, UV-Vis-NIR, and single bundle Raman spectroscopy. The introduction of functional, oxygen-containing groups is revealed by an additional absorption band at 1725 cm−1, characteristic of carbonyl stretch vibrations. No significant shift of the optical absorption bands could be detected after oxidation. The combination of atomic force microscopy and confocal scanning resonance-enhanced Raman microscopy was used to investigate thin bundles and, eventually, individual nanotubes in detail. These experiments enabled determination of the dependence of the Raman intensity of the G-line (around 1590 …

ConfocalAnalytical chemistryGeneral ChemistryCarbon nanotubelaw.inventionOptical properties of carbon nanotubeschemistry.chemical_compoundsymbols.namesakechemistrylawNitric acidAbsorption bandMicroscopysymbolsRaman spectroscopyAbsorption (electromagnetic radiation)Israel Journal of Chemistry
researchProduct

Thermoreversible gelation of kappa-carrageenan: relation between conformational transition and aggregation.

2003

Abstract We have studied, by optical rotation dispersion, light scattering and rheology, the κ-Carrageenan system to elucidate the processes involved in gel formation (on decreasing the temperature) and gel melting (on increasing the temperature). Our results show that, on decreasing the temperature, a conformational transition from coils to double helices first occurs, followed by aggregation of the double helices into domains and gel formation at appropriate polymer concentration. Structural details of this sequence are better revealed by re-heating the system. Melting appears as a two-step process characterized by first a conformational change of helices involved in junction zones betwee…

Conformational changeGelationTime FactorsOptical RotationBiophysicsMolecular ConformationCarrageenanBiochemistryLight scatteringPhase TransitionRheologyScattering RadiationTransition TemperatureTexture (crystalline)Optical rotationchemistry.chemical_classificationChemistryOrganic ChemistryTemperatureSelf-assemblyPolymerCrystallographySelf-assemblyDispersion (chemistry)RheologyGelsBiophysical chemistry
researchProduct