Search results for "RADIATION"
showing 10 items of 5298 documents
The Allosteric Effector l-Lactate Induces a Conformational Change of 2×6-meric Lobster Hemocyanin in the Oxy State as Revealed by Small Angle X-ray S…
2001
Abstract Hemocyanins are multisubunit respiratory proteins found in many invertebrates. They bind oxygen highly cooperatively. However, not much is known about the structural basis of this behavior. We studied the influence of the physiological allosteric effectorl-lactate on the oxygenated quaternary structure of the 2×6-meric hemocyanin from the lobster Homarus americanus employing small angle x-ray scattering (SAXS). The presence of 20 mm l-lactate resulted in different scattering curves compared with those obtained in the absence of l-lactate. The distance distribution functionsp(r) indicated a more compact molecule in presence ofl-lactate, which is also reflected in a reduction of the …
Small-angle neutron scattering reveals an oxygen-dependent conformational change of the immunogen keyhole limpet hemocyanin type 1 (KLH1).
2001
The respiratory protein of the keyhole limpet, Megathura crenulata, the hemocyanin (KLH), commonly used as an immunogen, binds oxygen cooperatively, which implies the existence of different conformations. For the first time, two different conformations of KLH1 were detected upon oxygenation, a deoxy and an oxy state, using small-angle neutron scattering. Rearrangements in the quaternary structure of KLH1 were predicted from the different radii of gyration and the shifts of the minima and maxima in the scattering curves. Upon oxygenation, KLH1 becomes smaller and more compact. Model reconstruction of KLH1 indicates a hollow cylinder with two rings located close to both ends, which move sligh…
Protofibril formation of amyloid beta-protein at low pH via a non-cooperative elongation mechanism.
2005
Deposition of the amyloid beta-protein (Abeta) in senile or diffuse plaques is a distinctive feature of Alzheimer's disease. The role of Abeta aggregates in the etiology of the disease is still controversial. The formation of linear aggregates, known as amyloid fibrils, has been proposed as the onset and the cause of pathological deposition. Yet, recent findings suggest that a more crucial role is played by prefibrillar oligomeric assemblies of Abeta that are highly toxic in the extracellular environment. In the present work, the mechanism of protofibril formation is studied at pH 3.1, starting from a solution of oligomeric precursors. By combining static light scattering and photon correla…
Italian inter-society expert panel position on radiological exposure in Neonatal Intensive Care Units.
2020
Abstract Background In the recent years, clinical progress and better medical assistance for pregnant women, together with the introduction of new complex technologies, has improved the survival of preterm infants. However, this result requires frequent radiological investigations mostly represented by thoracic and abdominal radiographs in incubators. This document was elaborated by an expert panel Italian inter-society working group (Radiologists, Paediatricians, Medical Physicists) with the aim to assist healthcare practitioners in taking choices involving radiation exposures of new-born infants and to provide practical recommendations about justification and optimization in Neonatal Inte…
Intercomparing different devices for the investigation of ice nucleating particles using Snomax<sup>®</sup> as test subst…
2015
Abstract. Seven different instruments and measurement methods were used to examine the immersion freezing of bacterial ice nuclei from Snomax® (hereafter Snomax), a product containing ice-active protein complexes from non-viable Pseudomonas syringae bacteria. The experimental conditions were kept as similar as possible for the different measurements. Of the participating instruments, some examined droplets which had been made from suspensions directly, and the others examined droplets activated on previously generated Snomax particles, with particle diameters of mostly a few hundred nanometers and up to a few micrometers in some cases. Data were obtained in the temperature range from −2 to …
The diagnosis and management of gastric cancer: Expert discussion and recommendations from the 12th ESMO/World Congress on Gastrointestinal Cancer, B…
2011
Well-recognized experts in the field of gastric cancer discussed during the 12th European Society Medical Oncology (ESMO)/World Congress Gastrointestinal Cancer (WCGIC) in Barcelona many important and controversial topics on the diagnosis and management of patients with gastric cancer. This article summarizes the recommendations and expert opinion on gastric cancer. It discusses and reflects on the regional differences in the incidence and care of gastric cancer, the definition of gastro-esophageal junction and its implication for treatment strategies and presents the latest recommendations in the staging and treatment of primary and metastatic gastric cancer. Recognition is given to the ne…
Aufbau und Arbeitsweise eines 12-Kanal- funktionsmeβstandes zur Erfassung und Auswertung schnell ablaufender hämodynamischer Vorgänge
1970
Hemodynamic function studies with radioactive tracers A new set-up, a multichannel function test device, is described for performing hemodynamic function studies with radioactive tracers. After injection of radioactive labelled particles of definite physical and chemical properties, the distribution of radioactivity can be registered simultaneously as function of time at 6 different sites of the body. Each of the 6 detectors used, one of them can be replaced by a fore-arm counter, is equipped with two channels, which can be individually adjusted to the photopeaks of two different radioisotopes. The data are either/not only stored on magnetic tape or/but also fed into a memory unit operating…
Cone-beam computed tomography in lung stereotactic ablative radiation therapy: predictive parameters of early response
2016
To analyze lung lesion volume variations by contouring on cone-beam CT (CBCT) images to evaluate the early predictive parameters of stereotactic ablative radiation therapy (SABR) treatment response.The prescribed dose of SABR was varied according to the tumour site (central or peripheral) and maximum diameter of the lesions by using a strategy of risk-adapted dose prescription with a dose range between 48 and 70 Gy in 3-10 consecutive fractions. For the purpose of the analysis, the gross tumour volume (GTV) was recontoured for each patient at first and last CBCT using two lung levels/windows: (a) -600/1000 HU and (b) -1000/250 HU. Univariate analysis was performed to evaluate a correlation …
9 Development of an experimental tool to evaluate normal tissue 3D doses in external-beam radiotherapy
2018
Introduction Recently, cancer treatment improvement enabled an increase in patients’ survival rate. In more than half of the cases, radiotherapy participates in the cure for cancer. The efficacy of this technique is well known but it inevitably delivers doses to normal tissues exposing them to radio-induced complications risks [1] . Moreover, the longer patients’ life expectancy increases the risk of developing long-term complications such as second cancers. Thus, evaluating the risks following cancer treatment involving radiotherapy constitutes a major challenge. In this context, an experimental tool has been developed to evaluate normal tissue doses delivered by the different radiotherapy…
SU-FF-T-365: Practical Reconstruction Method for 3D CT-Based Brachytherapy with Shielded Colpostats
2006
Introduction and purpose.‐ The most extended worldwide HDR and PDR afterloading machines are from Nucletron, using the Plato Treatment Planning System (TPS) to perform the clinical dosimetry. The Fletcher‐Williamson (FW) vaginal colpostat applicators are widely used with these machines, they are made of a very dense material (densimet‐17) which allows shielding up to 50% of the dose. Almost all the TPS have incorporated the CT‐Based Brachytherapy (BT), in which the CT catheters and applicators reconstruction is based on contiguous CT transverse slices where the user points the catheter position. The problem with these applicators is the production of artefacts that makes the reconstruction …