Search results for "RADIOTHERAPY"
showing 10 items of 473 documents
Multiparametric MRI and post implant CT-based dosimetry after prostate brachytherapy with iodine seeds: The higher the dose to the dominant index les…
2015
Abstract Purpose To determine whether post-implant MRI-based dosimetry of the Dominant Intra-prostatic Lesion (DIL) could best predict the occurrence of PSA bounce after prostate brachytherapy. Methods and materials We selected 66 patients with a low risk prostate cancer treated with 125 I prostate brachytherapy as monotherapy. Post-implant dosimetry based on day 30 CT-scan and multiparametric MRI co-registration was generated: planned D 90, D 95, V 100, V 150 values were calculated for each DIL. Bounce was defined as a PSA elevation ⩾0.2ng/mL from the previous baseline value followed by a decrease to or below the prior nadir with no additional treatment. Results After a median follow-up of…
Prediction of Normal Organ Absorbed Doses for [177Lu]Lu-PSMA-617 Using [44Sc]Sc-PSMA-617 Pharmacokinetics in Patients With Metastatic Castration Resi…
2018
In vivo pharmacokinetic analysis of [Sc]Sc-PSMA-617 was used to determine the normal organ-absorbed doses that may result from therapeutic activity of [Lu]Lu-PSMA-617 and to predict the maximum permissible activity of [Lu]Lu-PSMA-617 for patients with metastatic castration-resistant prostate carcinoma. Methods Pharmacokinetics of [Sc]Sc-PSMA-617 was evaluated in 5 patients with metastatic castration-resistant prostate carcinoma using dynamic PET/CT, followed by 3 static PET/CT acquisitions and blood sample collection over 19.5 hours, as well as urine sample collection at 2 time points. Total activity measured in source organs by PET imaging, as well as counts per milliliter measured in bloo…
Interactive multiobjective optimization for anatomy-based three-dimensional HDR brachytherapy.
2010
In this paper, we present an anatomy-based three-dimensional dose optimization approach for HDR brachytherapy using interactive multiobjective optimization (IMOO). In brachytherapy, the goals are to irradiate a tumor without causing damage to healthy tissue. These goals are often conflicting, i.e. when one target is optimized the other will suffer, and the solution is a compromise between them. IMOO is capable of handling multiple and strongly conflicting objectives in a convenient way. With the IMOO approach, a treatment planner’s knowledge is used to direct the optimization process. Thus, the weaknesses of widely used optimization techniques (e.g. defining weights, computational burden an…
Fogging effect correction of Gafchromic HD-V2 film response for its use in high-dose radiotherapy
2020
GAFChromic® HD-V2 film is a reliable dose measurement device, thin, flexible, inexpensive, simple to use and easy to analyze. The response in terms of net absorbance with respect to absorbed dose was found to be linear in a large dose range, which supports the feasibility of using the film dosimeters in many applications, such as radiotherapy. For its use, a "fogging" effect must be take into account since film response changes with time. To determine a calibration curve valid for any time, fogging effect was investigated for more than 400 days. A correction procedure allows the use of HD-V2 film dosimeters in high-dose radiotheraphy, as brachytherapy, and quality assurance (QA) procedures.
Response charactterization of ammonium tartrate solid state pellets for ESR dosimetry with radiotherapeutic photon and electron beams.
2001
Solid state pellets (1 mm thick) for electron spin resonance (ESR) dosimetry were made using ammonium tartrate as the radiation-sensitive substance. Their behaviour was experimentally investigated as a function of dose with 60Co gamma rays. The calibration function obtained permits measurements of absorbed dose in the 2-50 Gy range, with a combined uncertainty of +/-4%. The lowest detectable dose was about 0.5 Gy. These properties are comparable with or even better than those of ESR dosimeters made from other materials. The time stability of the ESR signal of ammonium tartrate dosimeters at different storage conditions after irradiation was studied. A rather complex behaviour was observed, …
Radiobiological characterization of human tumor cell multilayers after conventional and particle irradiation.
2006
The goal of this study was to establish planar multilayers from human tumor cells (WiDr and SiHa) as a model for irradiation of solid tumors. In addition to using conventional X rays (250 kV) as a reference standard, multilayers were tested for their suitability in cell survival studies with heavy-ion irradiation ((12)C(6+)) in the plateau and the extended Bragg peak with a scanned ion beam. Multilayers of both cell lines showed decreased survival compared to the corresponding monolayers after both X and heavy-ion irradiation. This multicellular sensitization effect is in contrast to the multicellular resistance or contact effect commonly described in the literature. Flow cytometry measurem…
A Monte Carlo study of intersource effects in dome-type applicators loaded with LDR Cs-137 sources
2005
In this study, the dose rate distributions produced by low dose rate Cs-137 sources loaded in afterloadable dome applicators are studied using the Monte Carlo method. Dose differences between Monte Carlo results and calculations done using the superposition principle are within 1-3% in front of the applicator and between 3 and 10% near and along the longitudinal source axis. Consequently, the real doses to lateral vaginal wall, rectum and bladder are very close to the doses estimated applying the superposition principle, while the dose to the vaginal cuff has been overestimated by up to 10%.
A monte carlo study of dose rate distribution around the specially asymmetric CSM3-a 137Cs source.
2001
The CSM3 137Cs type stainless-steel encapsulated source is widely used in manually afterloaded low dose rate brachytherapy. A specially asymmetric source, CSM3-a, has been designed by CIS Bio International (France) substituting the eyelet side seed with an inactive material in the CSM3 source. This modification has been done in order to allow a uniform dose level over the upper vaginal surface when this `linear' source is inserted at the top of the dome vaginal applicators. In this study the Monte Carlo GEANT3 simulation code, incorporating the source geometry in detail, was used to investigate the dosimetric characteristics of this special CSM3-a 137Cs brachytherapy source. The absolute do…
Improving bleeding detector features for electron intraoperative radiotherapy
2019
Abstract Purpose The aim of this work is to improve the potential bleeding detection during intraoperative radiotherapy with linac polymethyl methacrylate applicators (PMMA), based on one previously developed. The improvements carried out have been focused on: i) minimizing the impact of the detector on the visual through the plastic applicators and ii) avoiding the asymmetry in the detection capability when the applicator is tilted. Methods Simulations have been made to select the geometry that provides a reduced visual impact on the applicator as well as allowing an independent response with the tilting angle of the applicator. A low-noise circuit for signal conditioning has been develope…
The "PC-WIRED" study: Patient Centred Evolution of Websites of Italian Radiotherapy Departments.
2021
Abstract Objectives The aim of this paper was to conduct a survey about the evolution of the information provided by Italian radiotherapy departments with a special focus on patients’ perspective. Methods A two-steps analysis was conducted in 2013 and 2020. Starting from analysis of data for the existing websites of Italian radiotherapy departments, main potential areas of interest for patients were discussed within a dedicated multidisciplinary team composed of radiation oncologists, a web designer, a blogger, a psyco-oncologist, a volunteer and a representative of patients’ association. Results Six patient-oriented features to evaluate the websites of Italian radiotherapy departments were…