Search results for "RDW"
showing 10 items of 1401 documents
Low-Cost Sensor Based on SDR Platforms for TETRA Signals Monitoring
2021
The paper presents the design and implementation of an electromagnetic field monitoring sensor for the measurement of the Terrestrial Truncked Radio (TETRA) signals using low-cost software defined radio (SDR) platforms. The sensor includes: an SDR platform, a Global Positioning System (GPS) module and a hardware control module. Several SDR platforms having different resolutions of the analog–digital converters were tested in the first phase. The control module was implemented in two variants: a fixed one, using a laptop, and a mobile one, using a Raspberry Pi. The tests demonstrate the following achieved performances: instantaneous acquisition band of 5.12 MHz
A new ATLAS muon CSC readout system with system on chip technology on ATCA platform
2015
The ATLAS muon Cathode Strip Chamber (CSC) backend readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run 2 luminosity. The readout design is based on the Reconfigurable Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the Advanced Telecommunication Computing Architecture (ATCA) platform. The RCE design is based on the new System on Chip XILINX ZYNQ series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources together with auxiliary memories to form a versatile DAQ building block that can host applicati…
Simulation of parasitic effects on Silicon Carbide devices for automotive electric traction
2020
Wide Band Gap (WBG) semiconductors are increasingly addressed towards Electric Vehicle (EV) applications, due to their significant advantages in terms of high-voltage and low-losses performances, suitable for high power applications. Nevertheless, the packaging in WBG devices represents a challenge for designers due to the notable impact that inductive and capacitive parasitic components can bring in high switching frequency regime in terms of noise and power losses. In this paper, a comparison between conventional Silicon (Si) and emerging Silicon-Carbide (SiC) power switching devices is presented. The effects of inductive parasitic effects and switching frequency are investigated in simul…
Nanostructured lead acid battery for electric vehicles applications
2017
This paper presents an innovative lead acid battery, based on nanostructured active materials. Both charging time and specific energy are greatly enhanced in comparison with commercial lead acid battery. Starting from the extremely valuable performances of the nanostructured battery, also a circuital model, for application in electric vehicle traction, has been specifically developed. The circuital model has demonstrated that an enhanced nanostructured battery allows an increase of traveled distance by electric vehicles.
Performances of the Fault Decoupling Device when unbalanced and multiple faults occur on distribution systems.
2005
Nowadays industrial processes are largely based on electronic devices such as programmable logic controllers and adjustable speed drives. Consequently, industrial equipments became less tolerant towards power supply disturbances. Voltage dips due to faults are surely among the worst disturbances for industrial equipments. A paper machine can be affected by disturbances of only 10% voltage drop lasting for 100 ms. A voltage dip of 75% (of the nominal voltage) with a duration shorter than 100 ms results in material loss in the range of thousands of US Dollars for semiconductors industry [1].
Real-time data processing in the ALICE High Level Trigger at the LHC
2019
At the Large Hadron Collider at CERN in Geneva, Switzerland, atomic nuclei are collided at ultra-relativistic energies. Many final-state particles are produced in each collision and their properties are measured by the ALICE detector. The detector signals induced by the produced particles are digitized leading to data rates that are in excess of 48 GB/$s$. The ALICE High Level Trigger (HLT) system pioneered the use of FPGA- and GPU-based algorithms to reconstruct charged-particle trajectories and reduce the data size in real time. The results of the reconstruction of the collision events, available online, are used for high level data quality and detector-performance monitoring and real-tim…
Development of a microfluidic design for an automatic lab-on-chip operation
2016
Simple and easy to use are the keys for developing lab-on-chip technology. Here, a new microfluidic circuit has been designed for an automatic lab-on-chip operation (ALOCO) device. This chip used capillary forces for controlled and precise manipulation of liquids, which were loaded in sequence from different flowing directions towards the analysis area. Using the ALOCO design, a non-expert user is able to operate the chip by pipetting liquids into suitable inlet reservoirs. To test this design, microfluidic devices were fabricated using the programmable proximity aperture lithography technique. The operation of the ALOCO chip was characterized from the flow of red-, blue- and un-dyed deioni…
A hardware skin-segmentation IP for vision based smart ADAS through an FPGA prototyping
2017
International audience; In this paper we presents a platform based design approach for fast HW/SW embedded smart Advanced Driver Assistant System (ADAS) design and prototyping. Then, we share our experience in designing and prototyping a HW/SW vision based smart embedded system as an ADAS that helps to increase the safety of car's drivers. We present a physical prototype of the vision ADAS based on a Zynq FPGA. The system detects the fatigue state of the driver by monitoring the eyes closure and generates a real-time alert. A new HW/SW codesign skin segmentation step to locate the eyes/face is proposed. Our presented new approach migrates the skin segmentation step from processing system (S…
Isolation of Adult Rat Cardiomyocytes Using Recombinant Collagenases
2018
Direct isolation of primary cells from tissues and organs allows for the maintenance of important cell characteristics and properties for in vitro studies and a plethora of biomedical applications. Dissociation of cells from the organ of interest is possible due to the enzymatic activity of collagenases. The choice and the dose of these enzymes is the critical step to obtain the maximum number of cells with intact structure and function. In this contest, Abiel collagenases class I (Col G) and class II (Col H) were synthesised using recombinant DNA technologies and their ability to degrade collagen in cell isolation from different tissues was tested. Examples of cells isolated with these enz…
Alkaline Pre-treatment of Hardwood Chips Prior to Delignification
2013
Scots pine (Pinus sylvestris) chips were pre-treated with alkaline solutions (alkali charges of 1, 2, 3, 4, 6, and 8% of NaOH on the oven-dried wood material) at 130°C and 150°C for various treatment times (30, 60, 90, and 120 minutes). Under these conditions, 2.0–13.6% of the wood d.s. was dissolved into the aqueous hydrolysates. The soluble organic fraction was primarily characterized in terms of carbohydrates (monosaccharides and oligo-/polysaccharides) and their alkali-catalyzed degradation products: aliphatic carboxylic acids containing, besides non-volatile hydroxy carboxylic acids, volatile formic and acetic acids. With increasing alkali charge, temperature, and time, the enhanced fo…