Search results for "RENT"
showing 10 items of 14059 documents
Structural characterization and electrochemical hydrogen storage properties of Ti2LxZrxNi (x [ 0, 0.1, 0.2) alloys prepared by mechanical alloying
2013
International audience; Nominal Ti2Ni was synthesized under argon atmosphere at room temperature using a planetary high-energy ball mill. The effect of milling time and Zr substitution for Ti on the microstructure was characterized by XRD, SEM and TEM, and the discharge capacities of Ti2xZrxNi (x 1/4 0, 0.1, 0.2) were examined by electrochemical measurements at galvanostatic conditions. XRD analysis shows that amorphous phase of Ti2Ni can be elaborated by 60 h of milling, whereas Zr substitution hinders amorphization process of the system. The products of ball milling nominal Ti2xZrxNi (x 1/4 0.1, 0.2) were austenitic (Ti, Zr)Ni and partly TiO, despite the fact that the operation was carrie…
Custom measurement system for memristor characterisation
2021
Abstract A cheap, compact and customisable characterisation system for memristor devices, working between ± 10 V, is presented. SPICE (Simulation Program with Integrated Circuit Emphasis) simulations are performed to verify the circuit feasibility and a proper software is developed to drive the system. The potentiality of the realised system is tested by performing several electrical measurements on both Cu/HfO2/Pt memristors and two-terminals commercial devices.
A General Mathematical Formulation for the Determination of Differential Leakage Factors in Electrical Machines with Symmetrical and Asymmetrical Ful…
2018
This paper presents a simple and general mathematical formulation for the determination of the differential leakage factor for both symmetrical and asymmetrical full and dead-coil windings of electrical machines. The method can be applied to all multiphase windings and considers Gorges polygons in conjunction with masses geometry in order to find an easy and affordable way to compute the differential leakage factor, avoiding the adoption of traditional methods that refer to the Ossanna's infinite series, which has to be obviously truncated under the bound of a predetermined accuracy. Moreover, the method described in this paper allows the easy determination of both the minimum and maximum v…
Determination of differential leakage factors in electrical machines with non-symmetrical full and dead-coil windings
2017
In this paper Gorges polygons are used in conjunction with masses geometry to find an easy and affordable way to compute the differential leakage factor of non symmetrical full and dead coil winding. By following the traditional way, the use of the Ossanna's infinite series which has to be obviously truncated under the bound of a predetermined accuracy is mandatory. In the presented method no infinite series is instead required. An example is then shown and discussed to demonstrate practically the effectiveness of the proposed method.
A New Approach to Partial Discharge Detection Under DC Voltage: Application to Different Materials
2021
Usability of a new Direct Current Periodic waveform for partial discharge qualification in HVDC systems is exemplified by tests performed on different materials.
Partial discharges behavior under different rectified waveforms
2017
In this work, a previous software used to simulate partial discharges (PDs) under Alternating Current (AC) stress has been modified in order to evaluate the PDs behavior under a voltage stress close to the Direct Current (DC) waveform. By using a full-wave and a half-wave rectifier, the specimen with an air void defects has been subjected to a gradual constant stress. Finally, a capacitive filter has been inserted in order to produce a steadier voltage supply. Simulation results show that under an almost DC waveform, the PDs activity become less compared to AC stress.
Analog isolated electronic dynamometer based on a magnetoresistive current sensor.
2017
In this work, an electronic system is presented to measure the force applied by a solenoid. The originality of the work is focused on the use of a magnetoresistive current sensor to provide the isolation barrier needed in the actual industrial plant where the solenoids are working. The design of the electronic system is presented as well as experimental measurements as a result of a calibration process showing a negligible hysteresis with that specific sensor. The magnetoresistive current sensor is used to develop transmission functions rather than playing its usual sensing roles.
An exact method for the determination of differential leakage factors in electrical machines with non-symmetrical windings
2016
An exact and simple method for the determination of differential leakage factors in polyphase ac electrical machines with non-symmetrical windings is presented in this paper. The method relies on the properties of Gorges polygons that are used to transform an infinite series expressing the differential leakage factor into a finite sum in order to significantly simplify the calculations. Some examples are shown and discussed in order to practically demonstrate the effectiveness of the proposed method.
Contributed Review: Review of thermal methods for space charge measurement.
2016
The space charge accumulation phenomenon has garnered great interest over the last two decades because of the increased use of direct current in high voltage electrical systems. In this context, a significant relevance has been achieved by the thermal methods, used for solid dielectrics. This paper presents a review of this non-destructive measurement system used for the measurement of space charge. The thermal pulse method, the thermal step method, and the laser intensity modulation method are described. For each configuration, the principle of operation, the thicknesses analyzed, and the spatial resolution are described, reporting also the main related applications
Space Charge Measurement under DC and DC Periodic Waveform
2018
In High Voltage systems, Partial Discharges (PDs) monitoring are one of the main diagnostic instrument to evaluate the reliability of the apparatus. Under Alternating Current (AC) stress, PDs detection and recognition techniques are well consolidated. On the contrary, the monitoring of PDs under Direct Current (DC) stress is difficult due to complexities related to the nature of the phenomenon, which cause the beginning of PDs events in proximity of the dielectric breakdown. This problem has been partially overcome by using a continuous Periodic waveform (DCP) with positive average value, as described in a recent published work. Under DC stress, another degradation factor is the Space Charg…