Search results for "RESONANCE IONIZATION"
showing 10 items of 51 documents
Laser ion beam production at CERN-ISOLDE: New features – More possibilities
2016
Abstract This article summarizes the current specifications and the latest features of the CERN-ISOLDE resonance ionization laser ion source (RILIS). This includes a description of the optical layout and the newly designed reference system. The ionization schemes for the laser ionized beams at ISOLDE are tabulated, including six new elements. All RILIS schemes are also made publicly available in the RILIS elements on-line database. Finally, we announce a paradigm shift in RILIS operation – the combination of a machine protection and a monitoring and control system has enabled on-call operation of the laser ion source for selected beams in 2014 and has become the standard mode of operation i…
Excited atomic energy levels in protactinium by resonance ionization spectroscopy
2018
We present high-resolution data of the single-excitation spectrum of protactinium, reaching slightly beyond the first-ionization threshold. Within this work, more than 1500 energy levels are recorded in different excitation energy ranges below $50\phantom{\rule{0.16em}{0ex}}000\phantom{\rule{4pt}{0ex}}{\mathrm{cm}}^{\ensuremath{-}1}$. Our experimental results show that the tabulated data in the literature severely underestimate the density of states particularly regarding the highly excited spectral range.
First Observation of Atomic Levels for the Element Fermium (Z=100)
2003
The atomic level structure of the element fermium was investigated for the first time using a sample of $2.7\ifmmode\times\else\texttimes\fi{}{10}^{10}$ atoms of the isotope $^{255}\mathrm{F}\mathrm{m}$ with a half-life of 20.1 h. The atoms were evaporated from a filament and stored in the argon buffer gas of an optical cell. Atomic levels were sought by the method of resonance ionization spectroscopy using an excimer-dye-laser combination. Two atomic levels were found at wave numbers $(25\text{ }099.8\ifmmode\pm\else\textpm\fi{}0.2)$ and $(25\text{ }111.8\ifmmode\pm\else\textpm\fi{}0.2)\text{ }\text{ }{\mathrm{c}\mathrm{m}}^{\ensuremath{-}1}$. Partial transition rates to the $5{f}^{12}7{s}…
Development of High Resolution Resonance Ionization Mass Spectrometry for Neutron Dosimetry Technique with93Nb(n,n')93mNb Reaction
2016
We have proposed an advanced technique to measure the 93mNb yield precisely by Resonance Ionization Mass Spectrometry, instead of conventional characteristic X-ray spectroscopy. 93mNb-selective resonance ionization is achievable by distinguishing the hyperfine splitting of the atomic energy levels between 93Nb and 93mNb at high resolution. In advance of 93mNb detection, we could successfully demonstrate high resolution resonant ionization spectroscopy of stable 93Nb using an all solid-state, narrowband and tunable Ti:Sapphire laser system operated at 1 kHz repetition rate. peerReviewed
A complementary laser system for ISOLDE RILIS
2011
The Resonance Ionization Laser Ion Source (RILIS) is a powerful tool for efficient and selective production of radioactive ion beams at Isotope Separator On Line (ISOL) facilities. To avoid isobaric background, highly selective stepwise resonant ionization is applied, using up to three different laser wavelengths. Due to their advantages in terms of stability and reliability, an all solid-state titanium:sapphire (Ti:Sa) system is used or is planned to be installed at the majority of on-line facilities worldwide. Such an all solid-state Ti:Sa laser system is going to be installed at the ISOLDE RILIS at CERN alongside the well-established dye laser system.
High-resolution laser system for the S3-Low Energy Branch
2022
International audience; In this paper we present the first high-resolution laser spectroscopy results obtained at the GISELE laser laboratory of the GANIL-SPIRAL2 facility, in preparation for the first experiments with the S$^3$-Low Energy Branch. Studies of neutron-deficient radioactive isotopes of erbium and tin represent the first physics cases to be studied at S$^3$. The measured isotope-shift and hyperfine structure data are presented for stable isotopes of these elements. The erbium isotopes were studied using the $4f^{12}6s^2$$^3H_6 \rightarrow 4f^{12}(^3 H)6s6p$$J = 5$ atomic transition (415 nm) and the tin isotopes were studied by the $5s^25p^2 (^3P_0) \rightarrow 5s^25p6s (^3P_1)$…
Intracavity Frequency Doubling and Difference Frequency Mixing for Pulsed ns Ti:Sapphire Laser Systems at On-Line Radioactive Ion Beam Facilities
2015
Intra-cavity second harmonic generation of a Titanium:sapphire (Ti:sa) laser system has been used to improve the conversion efficiency to the second harmonic. Over the course of several experiments performance data spanning the whole wavelength range of a Ti:sa has been collected, which may be used as a guideline for future experiments. An average output power of up to 3.7 W was achieved, resulting in a conversion efficiency of >75 % to the second harmonic. A wavelength coverage from 340-525 nm has been demonstrated. To extend the wavelength range of the solid state laser system, difference frequency mixing has been applied to the intra-cavity doubled light and the fundamental output of a s…
Resolution Characterizations of JetRIS in Mainz Using 164Dy
2022
Atoms 10(2), 57 (2022). doi:10.3390/atoms10020057
Laser developments and high resolution resonance ionization spectroscopy of actinide elements
2014
Towards in-jet resonance ionization spectroscopy : An injection-locked Titanium:Sapphire laser system for the PALIS-facility
2018
This article presents a pulsed narrowband injection-locked Titanium:Sapphire laser aimed for high-resolution in-jet resonance ionization spectroscopy at the SLOWRI/PALIS at RIKEN. The laser has been integrated into the PALIS laser laboratory enabling it to be utilized with the existing broadband Titanium:Sapphire and dye lasers. The seed efficiency has been evaluated to be close to unity over the master laser wavelength range ∼ 753 to 791 nm, and the slope efficiency, namely the ratio of the pump power to the output power, was determined to be ∼ 30 % at 780 nm. A two-step ionization scheme with 386.4016 nm first step and 286.731 nm second step into an autoionizing state was developed for re…